Calibration-free regional RF shims for MR spectroscopy
Preprint
Abstract
Purpose: Sufficient control of the RF transmit field (B 1 + ) in small regions-of-interest (ROIs) is critical for single voxel MR spectroscopy at ultra-high field. Static RF shimming, using parallel transmit (pTx), can improve B 1 + , but must be calibrated for each participant and ROI, which limits its applicability. Additionally, specific-absorption-rate (SAR) becomes hard to predict. This work aimed to find RF shims, which can be applied to any participant, to produce the desired |B 1 + | within pre-defined target ROIs. Methods: RF shims were found offline by joint-optimisation on a database, comprising B 1 + maps from 11 subjects, considering ROIs in occipital cortex, hippocampus and posterior-cingulate, as well as the whole brain. The B 1 + magnitude achieved using calibration-free RF shims was compared to a tailored shimming approach, and MR spectra were acquired using tailored and calibration-free RF shimming in 4 participants. Global and local 10g SAR deposition were modelled. Results: Calibration-free RF shims resulted in similar |B 1 + | in small ROIs compared to tailored shimming, in addition to producing spectra of excellent quality and equivalent SNR. Only a small database size was required. SAR deposition was reduced compared to operating in quadrature mode for all ROIs. Conclusion: This work demonstrates that static RF shims, optimised offline for small regions in single voxel MRS, avoid the need for lengthy B 1 + mapping and pTx optimisation for each ROI and participant. Furthermore, power settings may be increased when using calibration-free shims to better take advantage of the flexibility provided by RF shimming for regional acquisition at ultra-high field.Keywords
All Related Versions
- Published version: Magnetic Resonance in Medicine, 86 (2), 611.
This publication has 30 references indexed in Scilit:
- Parallel transmission for ultrahigh‐field imagingNMR in Biomedicine, 2015
- Improved quantification precision of human brain short echo-time 1 H magnetic resonance spectroscopy at high magnetic field: A simulation studyMagnetic Resonance in Medicine, 2013
- Regional neurochemical profiles in the human brain measured by 1H MRS at 7 T using local B1 shimmingNMR in Biomedicine, 2011
- In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7TMagnetic Resonance in Medicine, 2009
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifactsNMR in Biomedicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Application of finite difference time domain method for the design of birdcage RF head coils using multi-port excitationsMagnetic Resonance Imaging, 2000