Supatana Auethavekiat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Supatana Auethavekiat has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Duangrat Gansawat
National Electronics and Computer Technology Center
3 shared publications - Anita Manassakorn
Center of Excellence in Glaucoma, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
2 shared publications Kitiya Ratanawongphaibul
Center of Excellence in Glaucoma, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
2 shared publicationsParichat Sermwuthisarn
Department of Electrical Engineering, Chulalongkorn University, Bangkok 10330, Thailand
2 shared publicationsVera Sa-Ing
Department of Electrical and Computer Engineering, Faculty of Engineering, King Mongkuts University of Technology North Bangkok, Bangkok, Thailand
2 shared publicationsVisanee Tantisevi
Center of Excellence in Glaucoma, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
2 shared publications
Latest Publications
- Open Access
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 145845-145856
GenVFNet: Generating Visual Field From Optical Coherence Tomography Angiography by Conditional Generative Adversarial Networks
Glaucoma investigations play an important role in glaucoma management. This study aimed to generate a visual field pattern deviation map (GenVF) from optical coherence tomography angiography (OCTA) using conditional generative adversarial networks (cGAN), namely GenVFNet. cGAN consisted of two components: generator and discriminator. The generator consisted of encoder and decoder blocks and the discriminator was the classification learner. The training data was Grad-CAM of OCTA (GradOCTA) of glaucomatous eyes. Only eyes with a visual field (VF) compatible with optic disc photograph (DP) and/or optical coherence tomography (OCT) were used. 100 eyes (90.9%) were used for training and the remaining 10 eyes (9.1%) for testing. To conform with the five severity levels in clinical diagnosis, we quantized the generated VF (GenRawVF) from GenVFNet into five levels and named the quantized image GenVF. In the experiment, GenRawVFs were compared with actual pattern deviation images (RealRawVF) using the structural similarity index measure (SSIM), normalized root mean square error (NRMSE), Fréchet inception distance (FID), and confusion matrix. The average ± 95%CI SSIM, NRMSE, and FID were 0.87 ± 0.02, 0.10 ± 0.6, and 7.54 ± 3.47, respectively. GenVFNet was able to construct GenVF, especially in the superior hemifield. In addition, GenVFNet was tested with VFs of eyes whose DP and/or OCT did not correlate with the available VF. According to the expert’s opinion, 81 eyes (65.8%) of GenVF were correlated with DP and/or OCT. This study demonstrated the potential of GenVFNet to construct a VF pattern deviation from the OCTA that would be a benefit for patients who cannot perform a reliable VF.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 145845-145856
Open AccessGenVFNet: Generating Visual Field From Optical Coherence Tomography Angiography by Conditional Generative Adversarial Networks
Glaucoma investigations play an important role in glaucoma management. This study aimed to generate a visual field pattern deviation map (GenVF) from optical coherence tomography angiography (OCTA) using conditional generative adversarial networks (cGAN), namely GenVFNet. cGAN consisted of two components: generator and discriminator. The generator consisted of encoder and decoder blocks and the discriminator was the classification learner. The training data was Grad-CAM of OCTA (GradOCTA) of glaucomatous eyes. Only eyes with a visual field (VF) compatible with optic disc photograph (DP) and/or optical coherence tomography (OCT) were used. 100 eyes (90.9%) were used for training and the remaining 10 eyes (9.1%) for testing. To conform with the five severity levels in clinical diagnosis, we quantized the generated VF (GenRawVF) from GenVFNet into five levels and named the quantized image GenVF. In the experiment, GenRawVFs were compared with actual pattern deviation images (RealRawVF) using the structural similarity index measure (SSIM), normalized root mean square error (NRMSE), Fréchet inception distance (FID), and confusion matrix. The average ± 95%CI SSIM, NRMSE, and FID were 0.87 ± 0.02, 0.10 ± 0.6, and 7.54 ± 3.47, respectively. GenVFNet was able to construct GenVF, especially in the superior hemifield. In addition, GenVFNet was tested with VFs of eyes whose DP and/or OCT did not correlate with the available VF. According to the expert’s opinion, 81 eyes (65.8%) of GenVF were correlated with DP and/or OCT. This study demonstrated the potential of GenVFNet to construct a VF pattern deviation from the OCTA that would be a benefit for patients who cannot perform a reliable VF.
- Open Access
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 95613-95622
GlauNet: Glaucoma Diagnosis for OCTA Imaging Using a New CNN Architecture
Glaucoma is a neurodegenerative disease that affects the optic nerve head and causes visual field defect. Current investigations focus on neural component which may overlook other important factors such as the vascular cause. The optical coherence tomography angiography (OCTA) imaging has been developed and provided quantitative parameters that showed good diagnostic accuracy to detect glaucoma. However, those parameters are based on image processing of observed clinical findings, therefore, some image information can be lost. Convolutional neural network has been successfully applied for automatic feature extraction and object classification. In this study, the glaucoma diagnosis network, namely GlauNet, has been proposed. GlauNet consists of two sections: the feature-extraction section and the classification section. The feature-extraction section has three convolutional layers. Each convolutional layer is followed by rectified linear unit and maximum pooling layer. The classification section contains five fully connected layers. GlauNet was trained with 258 glaucomatous and 439 non-glaucomatous eyes. The visualization of the feature-extraction section showed the highlight in the area of optic nerve head and retinal nerve fiber layer in the superotemporal and inferotemporal regions. It was then tested on 27 glaucomatous and 48 non-glaucomatous eyes. Its sensitivity and specificity were 88.9% with 89.6%, respectively. The area under receiver operating characteristic curve of GlauNet was 0.89. GlauNet was robust against the artifacts. Its sensitivity and specificity were still higher than 80% (82.4% and 80.3%, respectively) when tested on 88 poor-quality images.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 95613-95622
Open AccessGlauNet: Glaucoma Diagnosis for OCTA Imaging Using a New CNN Architecture
Glaucoma is a neurodegenerative disease that affects the optic nerve head and causes visual field defect. Current investigations focus on neural component which may overlook other important factors such as the vascular cause. The optical coherence tomography angiography (OCTA) imaging has been developed and provided quantitative parameters that showed good diagnostic accuracy to detect glaucoma. However, those parameters are based on image processing of observed clinical findings, therefore, some image information can be lost. Convolutional neural network has been successfully applied for automatic feature extraction and object classification. In this study, the glaucoma diagnosis network, namely GlauNet, has been proposed. GlauNet consists of two sections: the feature-extraction section and the classification section. The feature-extraction section has three convolutional layers. Each convolutional layer is followed by rectified linear unit and maximum pooling layer. The classification section contains five fully connected layers. GlauNet was trained with 258 glaucomatous and 439 non-glaucomatous eyes. The visualization of the feature-extraction section showed the highlight in the area of optic nerve head and retinal nerve fiber layer in the superotemporal and inferotemporal regions. It was then tested on 27 glaucomatous and 48 non-glaucomatous eyes. Its sensitivity and specificity were 88.9% with 89.6%, respectively. The area under receiver operating characteristic curve of GlauNet was 0.89. GlauNet was robust against the artifacts. Its sensitivity and specificity were still higher than 80% (82.4% and 80.3%, respectively) when tested on 88 poor-quality images.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 442-445
Semi-automatic PFU Counting Method by Double Thresholding and Two-Stage Segmentation
Virus quantification is the necessary step for measuring the vaccine efficiency. Plaque assay is the most popular method and quantified the virus in term of a Plaque Forming Unit (PFU). In this paper, a semi-automatic method for plaque assay from image taken by a mobile phone is proposed. Two thresholds in different color spaces are used to extract the PFUs: one for PFU at the center and one for PFU at the edge of a well. The cluster of PFU is segmented in two stages. In the first stage, watershed segmentation based on distance transform is applied to segment the distinct and large PFUs. In the second stage, the size is used to separate the blurry PFUs. The proposed method achieved 94% precision, 92% sensitivity and 6% counting error in the experiment on 30 samples stained with neutral red color.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 442-445
Semi-automatic PFU Counting Method by Double Thresholding and Two-Stage Segmentation
Virus quantification is the necessary step for measuring the vaccine efficiency. Plaque assay is the most popular method and quantified the virus in term of a Plaque Forming Unit (PFU). In this paper, a semi-automatic method for plaque assay from image taken by a mobile phone is proposed. Two thresholds in different color spaces are used to extract the PFUs: one for PFU at the center and one for PFU at the edge of a well. The cluster of PFU is segmented in two stages. In the first stage, watershed segmentation based on distance transform is applied to segment the distinct and large PFUs. In the second stage, the size is used to separate the blurry PFUs. The proposed method achieved 94% precision, 92% sensitivity and 6% counting error in the experiment on 30 samples stained with neutral red color.
- 19 April 2013
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 36 (2) , 177-191
Prediction of shape diameter undergoing coil embolization of saccular intracranial aneurysm treatment using a hybrid decision support system
The purpose of the study was to design a hybrid decision support system (HDSS) that could simulate the embolized coil selection pattern of the radiologists in aneurysms treatment. As the longest available length of the coils should be used in most cases, therefore only the shape diameter (SD) selection was modeled and varied. Ninety-eight aneurysms successfully treated by a radiologist with coil embolization were divided into two groups (86 for training and 12 randomly selected for validating). Eight aneurysms treated by another radiologist were also used to cross validate the proposed HDSS. The HDSS was developed using the classification and the linear regression methods (LRM). The dome and the width of an aneurysm were used as the system inputs. The system outputs were the SDs of the first three coils indexed according to the insertion order. The HDSS that consisted of Bagging classification and LRM achieved the highest accuracy for all cases. The errors were within 1 mm for the SD selection of the first two coils. For the third coil, the SD selection within 1 mm bound had 80 % accuracy. The experimental results indicated the feasibility of using the HDSS as the guidance for selecting the SDs of the first two coils. The selection of the third coil required more training data for the rarely used SD. Moreover, the cross validation with another radiologist showed the feasibility of using the proposed HDSS as the guidance, however further validation with more data is recommended.
- 19 April 2013
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 36 (2) , 177-191
Prediction of shape diameter undergoing coil embolization of saccular intracranial aneurysm treatment using a hybrid decision support system
The purpose of the study was to design a hybrid decision support system (HDSS) that could simulate the embolized coil selection pattern of the radiologists in aneurysms treatment. As the longest available length of the coils should be used in most cases, therefore only the shape diameter (SD) selection was modeled and varied. Ninety-eight aneurysms successfully treated by a radiologist with coil embolization were divided into two groups (86 for training and 12 randomly selected for validating). Eight aneurysms treated by another radiologist were also used to cross validate the proposed HDSS. The HDSS was developed using the classification and the linear regression methods (LRM). The dome and the width of an aneurysm were used as the system inputs. The system outputs were the SDs of the first three coils indexed according to the insertion order. The HDSS that consisted of Bagging classification and LRM achieved the highest accuracy for all cases. The errors were within 1 mm for the SD selection of the first two coils. For the third coil, the SD selection within 1 mm bound had 80 % accuracy. The experimental results indicated the feasibility of using the HDSS as the guidance for selecting the SDs of the first two coils. The selection of the third coil required more training data for the rarely used SD. Moreover, the cross validation with another radiologist showed the feasibility of using the proposed HDSS as the guidance, however further validation with more data is recommended.
- Open Access
- 20 March 2012
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2012 (1) , 68
Impulsive noise rejection method for compressed measurement signal in compressed sensing
The Lorentzian norm of robust statistics is often applied in the reconstruction of the sparse signal from a compressed measurement signal in an impulsive noise environment. The optimization of the robust statistic function is iterative and usually requires complex parameter adjustments. In this article, the impulsive noise rejection for the compressed measurement signal with the design for image reconstruction is proposed. It is used as the preprocessing for any compressed sensing reconstruction given that the sparsified version of the signal is obtained by utilizing octave-tree discrete wavelet transform with db8 as the mother wavelet. The presence of impulsive noise is detected from the energy distribution of the reconstructed sparse signal. After the noise removal, the noise corrupted coefficients are estimated. The proposed method requires neither complex optimization nor complex parameter adjustments. The performance of the proposed method was evaluated on 60 images. The experimental results indicated that the proposed method effectively rejected the impulsive noise. Furthermore, at the same impulsive noise corruption level, the reconstruction with the proposed method as the preprocessing required much lower measurement rate than the model-based Lorentzian iterative hard thresholding.
- 20 March 2012
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2012 (1) , 68
Open AccessImpulsive noise rejection method for compressed measurement signal in compressed sensing
The Lorentzian norm of robust statistics is often applied in the reconstruction of the sparse signal from a compressed measurement signal in an impulsive noise environment. The optimization of the robust statistic function is iterative and usually requires complex parameter adjustments. In this article, the impulsive noise rejection for the compressed measurement signal with the design for image reconstruction is proposed. It is used as the preprocessing for any compressed sensing reconstruction given that the sparsified version of the signal is obtained by utilizing octave-tree discrete wavelet transform with db8 as the mother wavelet. The presence of impulsive noise is detected from the energy distribution of the reconstructed sparse signal. After the noise removal, the noise corrupted coefficients are estimated. The proposed method requires neither complex optimization nor complex parameter adjustments. The performance of the proposed method was evaluated on 60 images. The experimental results indicated that the proposed method effectively rejected the impulsive noise. Furthermore, at the same impulsive noise corruption level, the reconstruction with the proposed method as the preprocessing required much lower measurement rate than the model-based Lorentzian iterative hard thresholding.
- Open Access
- 15 February 2012
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2012 (1) , 34
Robust reconstruction algorithm for compressed sensing in Gaussian noise environment using orthogonal matching pursuit with partially known support and random subsampling
The compressed signal in compressed sensing (CS) may be corrupted by noise during transmission. The effect of Gaussian noise can be reduced by averaging, hence a robust reconstruction method using compressed signal ensemble from one compressed signal is proposed. The compressed signal is subsampled for L times to create the ensemble of L compressed signals. Orthogonal matching pursuit with partially known support (OMP-PKS) is applied to each signal in the ensemble to reconstruct L noisy outputs. The L noisy outputs are then averaged for denoising. The proposed method in this article is designed for CS reconstruction of image signal. The performance of our proposed method was compared with basis pursuit denoising, Lorentzian-based iterative hard thresholding, OMP-PKS and distributed compressed sensing using simultaneously orthogonal matching pursuit. The experimental results of 42 standard test images showed that our proposed method yielded higher peak signal-to-noise ratio at low measurement rate and better visual quality in all cases.
- 15 February 2012
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2012 (1) , 34
Open AccessRobust reconstruction algorithm for compressed sensing in Gaussian noise environment using orthogonal matching pursuit with partially known support and random subsampling
The compressed signal in compressed sensing (CS) may be corrupted by noise during transmission. The effect of Gaussian noise can be reduced by averaging, hence a robust reconstruction method using compressed signal ensemble from one compressed signal is proposed. The compressed signal is subsampled for L times to create the ensemble of L compressed signals. Orthogonal matching pursuit with partially known support (OMP-PKS) is applied to each signal in the ensemble to reconstruct L noisy outputs. The L noisy outputs are then averaged for denoising. The proposed method in this article is designed for CS reconstruction of image signal. The performance of our proposed method was compared with basis pursuit denoising, Lorentzian-based iterative hard thresholding, OMP-PKS and distributed compressed sensing using simultaneously orthogonal matching pursuit. The experimental results of 42 standard test images showed that our proposed method yielded higher peak signal-to-noise ratio at low measurement rate and better visual quality in all cases.
- 1 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 383-386
Approximation method for interpolating affine parameters in doubling frame rate
The quality of the frame rate up-conversion depends on the accuracy of the motion parameters. 2D affine model describes the motion better than the popular 2D translation model; however, its parameters are difficult to interpolate. In this paper, the approximation method for interpolating the mid-point of 2D affine parameters is proposed. The affine transform is approximated as the 2D rigid transformation where the target x and y axes are not orthogonal. Trigonometry relationship is applied to interpolate rotational parameters. Conventional linear interpolation is applied to interpolate translational parameters. For video sequences containing complex motion, the reconstruction from the approximated affine parameters gave higher PSNR and visually better result than the one from the interpolated 2D translation parameters.
- 1 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 383-386
Approximation method for interpolating affine parameters in doubling frame rate
The quality of the frame rate up-conversion depends on the accuracy of the motion parameters. 2D affine model describes the motion better than the popular 2D translation model; however, its parameters are difficult to interpolate. In this paper, the approximation method for interpolating the mid-point of 2D affine parameters is proposed. The affine transform is approximated as the 2D rigid transformation where the target x and y axes are not orthogonal. Trigonometry relationship is applied to interpolate rotational parameters. Conventional linear interpolation is applied to interpolate translational parameters. For video sequences containing complex motion, the reconstruction from the approximated affine parameters gave higher PSNR and visually better result than the one from the interpolated 2D translation parameters.
- Open Access
- 10 September 2009
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 9 (2) , 223-235
Video Enhancement Based on A Robust Hampel Iterative SRR with a General Observation Model
This paper proposes a novel robust Super Resolution Reconstruction (SRR) framework that can enhance a real complex video sequence and is applicable to any noise models. Although SRR algorithms have received considerable attention within the traditional research community, these algorithms are typically very sensitive to their assumed model of data and noise, which limits their utility. The real noise models that corrupt the measured sequence are unknown; consequently, SRR algorithms using L1 or L2 norm may degrade the image sequence rather than enhance it therefore the robust norm applicable to several noise and data models is desired in SRR algorithms. This paper proposes a SRR framework based on the stochastic regularization technique of Bayesian MAP estimation by minimizing a cost function. In order to tolerate to any noise models, the Hampel norm is used for measuring the difference between the projected estimate of the high-resolution image and each low resolution image, and removing outliers in the data. Tikhonov regularization is used to remove artifacts from the final result and improve the rate of convergence. Moreover, in order to cope with real video sequences and complex motion sequences, this paper proposes a SRR General Observation Model (GOM or a±ne block-based transform) devoted to the case of nonisometric inter-frame motion. In the experimental section, the proposed framework can enhance real complex motion sequences, such as Suzie and Foreman sequence, and con¯rm the effectiveness of our algorithm and demonstrate its superiority to other SRR algorithms based on L1 and L2 norm for several noise models (such as AWGN, Poisson noise, Salt & Pepper noise and Speckle noise) at several noise power.
- 10 September 2009
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 9 (2) , 223-235
Open AccessVideo Enhancement Based on A Robust Hampel Iterative SRR with a General Observation Model
This paper proposes a novel robust Super Resolution Reconstruction (SRR) framework that can enhance a real complex video sequence and is applicable to any noise models. Although SRR algorithms have received considerable attention within the traditional research community, these algorithms are typically very sensitive to their assumed model of data and noise, which limits their utility. The real noise models that corrupt the measured sequence are unknown; consequently, SRR algorithms using L1 or L2 norm may degrade the image sequence rather than enhance it therefore the robust norm applicable to several noise and data models is desired in SRR algorithms. This paper proposes a SRR framework based on the stochastic regularization technique of Bayesian MAP estimation by minimizing a cost function. In order to tolerate to any noise models, the Hampel norm is used for measuring the difference between the projected estimate of the high-resolution image and each low resolution image, and removing outliers in the data. Tikhonov regularization is used to remove artifacts from the final result and improve the rate of convergence. Moreover, in order to cope with real video sequences and complex motion sequences, this paper proposes a SRR General Observation Model (GOM or a±ne block-based transform) devoted to the case of nonisometric inter-frame motion. In the experimental section, the proposed framework can enhance real complex motion sequences, such as Suzie and Foreman sequence, and con¯rm the effectiveness of our algorithm and demonstrate its superiority to other SRR algorithms based on L1 and L2 norm for several noise models (such as AWGN, Poisson noise, Salt & Pepper noise and Speckle noise) at several noise power.