Cornelis G. Olthof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cornelis G. Olthof has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dirk J. Bosch
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
1 shared publication - Michel M. R. F. Struys
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
1 shared publication Mireille A Edens
Department of Innovation and Science, Isala, Zwolle, The Netherlands
1 shared publication- Philip P. C. de Knijff
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
1 shared publication - Rianne M. Jongman
Department of Pathology and Medical Biology, Medical Biology section, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
1 shared publication Robbert J. Slingerland
Department of Clinical Chemistry, Isala, Zwolle, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 18 November 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (22) , 10362
Distribution and Cytotoxic Potential of NK Cell Subsets in Conventional and Immune-Protective Anesthetic Strategies: A Randomized Study in Colorectal Cancer Patients
Emerging evidence suggests that anesthesia can modulate natural killer (NK) cell activity, potentially influencing anti-tumor immunity. In this randomized study, 14 patients undergoing laparoscopic colorectal cancer surgery received an immune-protective anesthetic strategy (propofol/epidural/dexmedetomidine) or a conventional strategy (sevoflurane/opioids). Peripheral blood mononuclear cells (PBMCs) were collected preoperatively and at 24 and 48 h postoperatively. CD56+CD16+ NK-cell subsets were characterized by flow cytometry based on NKG2A, NKG2C, and KIR expression. Cytotoxic potential was assessed by intracellular perforin and granzyme B, and CD107a expression as a degranulation marker. Significant decreases from 0 to 48 h were observed in the conventional group for NKG2A+KIR+ double-positive (DP) NK cells (−0.69 percentage points, p = 0.02) and terminally differentiated (NKG2A−NKG2C−) NK cells (−2.22 percentage points, p = 0.02). CD107a expression in DP NK cells increased at 48 h versus baseline (+44.9% MFI, p = 0.04) only in the conventional group. Intracellular granzyme B (−3.38 percentage points; p = 0.02) and perforin levels (−4.56 percentage points, p = 0.04) decreased from 0 to 48 h in the conventional group. These findings suggest that an immune-protective anesthetic strategy may better preserve NK cell subset distribution and cytotoxic potential. However, given the modest magnitude of changes, these results should be interpreted as exploratory.
- 18 November 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (22) , 10362
Open AccessDistribution and Cytotoxic Potential of NK Cell Subsets in Conventional and Immune-Protective Anesthetic Strategies: A Randomized Study in Colorectal Cancer Patients
Emerging evidence suggests that anesthesia can modulate natural killer (NK) cell activity, potentially influencing anti-tumor immunity. In this randomized study, 14 patients undergoing laparoscopic colorectal cancer surgery received an immune-protective anesthetic strategy (propofol/epidural/dexmedetomidine) or a conventional strategy (sevoflurane/opioids). Peripheral blood mononuclear cells (PBMCs) were collected preoperatively and at 24 and 48 h postoperatively. CD56+CD16+ NK-cell subsets were characterized by flow cytometry based on NKG2A, NKG2C, and KIR expression. Cytotoxic potential was assessed by intracellular perforin and granzyme B, and CD107a expression as a degranulation marker. Significant decreases from 0 to 48 h were observed in the conventional group for NKG2A+KIR+ double-positive (DP) NK cells (−0.69 percentage points, p = 0.02) and terminally differentiated (NKG2A−NKG2C−) NK cells (−2.22 percentage points, p = 0.02). CD107a expression in DP NK cells increased at 48 h versus baseline (+44.9% MFI, p = 0.04) only in the conventional group. Intracellular granzyme B (−3.38 percentage points; p = 0.02) and perforin levels (−4.56 percentage points, p = 0.04) decreased from 0 to 48 h in the conventional group. These findings suggest that an immune-protective anesthetic strategy may better preserve NK cell subset distribution and cytotoxic potential. However, given the modest magnitude of changes, these results should be interpreted as exploratory.
- 9 September 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (2) , 479-485
Glucose measurements with accu check inform II versus hexokinase plasma method during surgery under general anesthesia, an observational cohort study
Purpose Limited research exists on translation of in-vitro glucose measurement interfering compounds to the in-vivo situation. We investigated whether Point-of-Care glucose measurements by Accu Chek Inform II (ACI II) were accurate to monitor glucose concentrations during surgery with general anesthesia by comparing with the reference laboratory hexokinase plasma glucose test. Method Patients undergoing surgery with general anesthesia were included. Anesthesia was maintained with either Sevoflurane or Total intravenous anesthesia (TIVA). Prior to and after induction, blood glucose was measured with ACI II and the hexokinase test. Bland-Altman analysis was performed to assess method agreement. Subgroup analyses on glucose measurement differences per type of maintenance anesthesia were performed. Results Thirty-nine patients were included, and 78 measurements were performed. All paired measurements had clinically acceptable agreement with a percentage error of 10.0% (95% CI 8.0 to 11.9). The mean difference (95% limits of agreement) between ACI II and hexokinase for all measurements was 0.0 mmol/L (-0.7 to 0.7 mmol/L). Before induction (n = 39), mean difference was -0.1 mmol/L (-0.6 to 0.4 mmol/L), and after induction (n = 39), mean difference was 0.1 mmol/L (-0.8 to 0.9 mmol/L). Further investigation showed the difference varied per test for patients receiving Sevoflurane compared to patients receiving TIVA (-0.2 ± 0.4 mmol/L vs. 0.4 ± 0.3 mmol/L, p < 0.001). Before and after induction, the difference between ACI II and hexokinase measurements increased for patients receiving Sevoflurane compared to patients receiving TIVA (0.4 ± 0.4 mmol/L vs. -0.4 ± 0.3 mmol/L, p < 0.001). Conclusion The agreement between glucose measurements using ACI II and the reference laboratory hexokinase test was clinically acceptable with a percentage error of 10.0% (95% CI 8.0 to 11.9). The use of TIVA may negatively affect the measurement performance of the ACI II.
- 9 September 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (2) , 479-485
Glucose measurements with accu check inform II versus hexokinase plasma method during surgery under general anesthesia, an observational cohort study
Purpose Limited research exists on translation of in-vitro glucose measurement interfering compounds to the in-vivo situation. We investigated whether Point-of-Care glucose measurements by Accu Chek Inform II (ACI II) were accurate to monitor glucose concentrations during surgery with general anesthesia by comparing with the reference laboratory hexokinase plasma glucose test. Method Patients undergoing surgery with general anesthesia were included. Anesthesia was maintained with either Sevoflurane or Total intravenous anesthesia (TIVA). Prior to and after induction, blood glucose was measured with ACI II and the hexokinase test. Bland-Altman analysis was performed to assess method agreement. Subgroup analyses on glucose measurement differences per type of maintenance anesthesia were performed. Results Thirty-nine patients were included, and 78 measurements were performed. All paired measurements had clinically acceptable agreement with a percentage error of 10.0% (95% CI 8.0 to 11.9). The mean difference (95% limits of agreement) between ACI II and hexokinase for all measurements was 0.0 mmol/L (-0.7 to 0.7 mmol/L). Before induction (n = 39), mean difference was -0.1 mmol/L (-0.6 to 0.4 mmol/L), and after induction (n = 39), mean difference was 0.1 mmol/L (-0.8 to 0.9 mmol/L). Further investigation showed the difference varied per test for patients receiving Sevoflurane compared to patients receiving TIVA (-0.2 ± 0.4 mmol/L vs. 0.4 ± 0.3 mmol/L, p < 0.001). Before and after induction, the difference between ACI II and hexokinase measurements increased for patients receiving Sevoflurane compared to patients receiving TIVA (0.4 ± 0.4 mmol/L vs. -0.4 ± 0.3 mmol/L, p < 0.001). Conclusion The agreement between glucose measurements using ACI II and the reference laboratory hexokinase test was clinically acceptable with a percentage error of 10.0% (95% CI 8.0 to 11.9). The use of TIVA may negatively affect the measurement performance of the ACI II.