Peter L. Herzog
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter L. Herzog has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alfons K. G. Felice
DirectSens Biosensors GmbH, Am Rosenbühel 38, 3400 Klosterneuburg, Austria
1 shared publication - Andrea Bocchino
Tyndall National Institute, University College Cork, Cork, Ireland
1 shared publication - Beate Steiner
DirectSens GmbH, Muthgasse 11, A-1190 Vienna, Austria
1 shared publication - Christian Leitner
DirectSens GmbH, Muthgasse 11, A-1190 Vienna, Austria
1 shared publication - Christoph Magnes
HEALTH - Institute for Biomedical Research and Technologies, Joanneum Research Forschungsgesellschaft mbH, Graz, Austria
1 shared publication - Conor O Mahony
Tyndall National Institute, University College Cork, Cork, Ireland
1 shared publication
Latest Publications
- Open Access
- 6 May 2024
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 40, e00398
Enzymatic detection of α-hydroxybutyrate, an important marker of insulin resistance, and comparison with LC-MS/MS detection
- 6 May 2024
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 40, e00398
Open AccessEnzymatic detection of α-hydroxybutyrate, an important marker of insulin resistance, and comparison with LC-MS/MS detection
- Open Access
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Detection of Lactate via Amperometric Sensors Modified With Direct Electron Transfer Enzyme Containing PEDOT:PSS and Hydrogel Inks
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Open AccessDetection of Lactate via Amperometric Sensors Modified With Direct Electron Transfer Enzyme Containing PEDOT:PSS and Hydrogel Inks
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.
- 17 January 2007
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
The Diesel SUV - Pushing Back Emission Frontiers
The current figure of Diesel market share in Europe of about 50% indicates a high market penetration of the HSDI Diesel engine. Due to increasing fuel prices and limited crude oil resources the worldwide demand for Diesel engines for the passenger car sector is increasing - even in typical gasoline markets like the united States. The key factors for the further success of the HSDI Diesel engine are the fulfillment of future worldwide emission legislation and that the production costs of the technologies necessary to do so, do not make it uncompetitive in comparison to the various gasoline engine concepts. Heavy SUVs with relatively small engines will therefore have to face the biggest challenge. For the EU5 proposal currently under discussion, such vehicles will have to be certified as passenger cars (vehicle category M) and are no longer allowed to use the LCV standards (Light Commercial Vehicles, vehicle category N1 - Class III), which means a NOx reduction of 50% in the European Driving Cycle (EDC) will be necessary. In the USA, the FTP75 driving cycle and the highly loaded US06 cycle are the challenges which have to be met. In this paper a system approach to cope with future emission legislation is discussed, based on multicylinder engine results with different technology packages applied. Following technology assessment, the individual potential of each package to achieve legislative targets in US and EU is deduced in addition, development scenarios for the US and EU are discussed and the possibility of commonising technologies in the two markets evaluated. This is carried out with the intention of identifying base technologies which can be applied world-wide, thus reducing development costs and achieving low unit costs through high production economies of-scale.
- 17 January 2007
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
The Diesel SUV - Pushing Back Emission Frontiers
The current figure of Diesel market share in Europe of about 50% indicates a high market penetration of the HSDI Diesel engine. Due to increasing fuel prices and limited crude oil resources the worldwide demand for Diesel engines for the passenger car sector is increasing - even in typical gasoline markets like the united States. The key factors for the further success of the HSDI Diesel engine are the fulfillment of future worldwide emission legislation and that the production costs of the technologies necessary to do so, do not make it uncompetitive in comparison to the various gasoline engine concepts. Heavy SUVs with relatively small engines will therefore have to face the biggest challenge. For the EU5 proposal currently under discussion, such vehicles will have to be certified as passenger cars (vehicle category M) and are no longer allowed to use the LCV standards (Light Commercial Vehicles, vehicle category N1 - Class III), which means a NOx reduction of 50% in the European Driving Cycle (EDC) will be necessary. In the USA, the FTP75 driving cycle and the highly loaded US06 cycle are the challenges which have to be met. In this paper a system approach to cope with future emission legislation is discussed, based on multicylinder engine results with different technology packages applied. Following technology assessment, the individual potential of each package to achieve legislative targets in US and EU is deduced in addition, development scenarios for the US and EU are discussed and the possibility of commonising technologies in the two markets evaluated. This is carried out with the intention of identifying base technologies which can be applied world-wide, thus reducing development costs and achieving low unit costs through high production economies of-scale.