Shicong Zhai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shicong Zhai has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Hao Liu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Lei Wang
China Electric Power Research Institute, Wuhan, China
1 shared publication Wei Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication- Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
1 shared publication - Yuntian Guo
School of Mechanics and Engineering Science, Peking University, Beijing, P.R. China
1 shared publication
Latest Publications
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Low Cut-Off Frequency Extension and Amplitude Decoupling Analysis in Non-Contact Transient Measurement
For the non-contact measurement system, the low frequency measuring and uncertainty analyzing are critical to obtain the accurate amplitude of the transient overvoltage. In this paper, the circuit parameters that affect the low cut-off frequency of the measurement system were analyzed. Then, based on impedance converter, the ±1 dB low cut-off frequency was reduced from 9.8 Hz to 0.25 Hz. Moreover, the transient overvoltage generated by the air insulated disconnector operation in the 500 kV AC switchyard of a ±800 kV high-voltage direct current (HVDC) converter station was measured by the developed system. The time and frequency domain characteristic of the transient overvoltage was obtained. The measured three-phase transient overvoltage voltages were recovered using the decoupling matrix. The uncertainty analysis was carried out based on the field waveforms. After that, the impacts of average times and voltage step amplitudes on the uncertainty was compared. And the optimal average number of times is 10 and the voltage step amplitude selection should be greater than 0.5 p.u. The analysis results indicated that the measurement uncertainties for both high-frequency overvoltage and power frequency are below 10%.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Low Cut-Off Frequency Extension and Amplitude Decoupling Analysis in Non-Contact Transient Measurement
For the non-contact measurement system, the low frequency measuring and uncertainty analyzing are critical to obtain the accurate amplitude of the transient overvoltage. In this paper, the circuit parameters that affect the low cut-off frequency of the measurement system were analyzed. Then, based on impedance converter, the ±1 dB low cut-off frequency was reduced from 9.8 Hz to 0.25 Hz. Moreover, the transient overvoltage generated by the air insulated disconnector operation in the 500 kV AC switchyard of a ±800 kV high-voltage direct current (HVDC) converter station was measured by the developed system. The time and frequency domain characteristic of the transient overvoltage was obtained. The measured three-phase transient overvoltage voltages were recovered using the decoupling matrix. The uncertainty analysis was carried out based on the field waveforms. After that, the impacts of average times and voltage step amplitudes on the uncertainty was compared. And the optimal average number of times is 10 and the voltage step amplitude selection should be greater than 0.5 p.u. The analysis results indicated that the measurement uncertainties for both high-frequency overvoltage and power frequency are below 10%.