Nikita Fedosov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nikita Fedosov has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Alexei Ossadtchi
HSE University, Moscow, Russian Federation and AXXX, Moscow, Russian Federation
11 shared publications - Daria Medvedeva
HSE University, Moscow, Russian Federation
5 shared publications - Ilia Semenkov
AXXX, Moscow, Russian Federation and HSE University, Moscow, Russian Federation
3 shared publications - Julia Yu. Nekrasova
Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology
3 shared publications - Milana Makarova
HSE University, Center for Bioelectric Interfaces, Moscow, Russia
2 shared publications Oleg Shevtsov
Centre for Bioelectric Interfaces Higher School of Economics, LLC, Life Improvement by Future Technologies Institute,Moscow,Russia
2 shared publications
Latest Publications
- 25 November 2026
- Published by IOP Publishing in Journal of Neural Engineering
Geometry matters in continuous EMG decoding: Comparing spatial representations across decoder architectures
Objective. Commercial myoelectric prostheses use discrete gesture classification and mode switching, limiting simultaneous and proportional hand control. Continuous surface electromyography (EMG) decoding offers a flexible alternative, but reconstruction remains challenging. Covariance matrices capture interchannel relationships, yet conventional decoders treat vectorized covariances as Euclidean features, disregarding manifold geometry. We investigated whether tangent-space projection improves continuous hand-kinematics decoding over raw covariance across decoder architectures. Approach. We compared raw covariance, tangent-space covariance and convolutional neural network features, each paired with linear regression, multilayer perceptron or long short-term memory (LSTM) decoders. The primary experiment decoded 20 joint angles from six-channel residual-limb EMG in four participants with transradial amputation, using tracked intact-hand movements as reference. To examine reproducibility across datasets, we repeated the comparison on NinaPro DB8, including 10 able-bodied participants and two with transradial amputation. Both evaluations were offline, with participant-specific training and testing. A separate exploratory online experiment used the primary EMG setup in two participants: one with a residual limb, one without upper-limb impairment. During attempted finger movements, the tangent-space and LSTM pipeline converted streaming EMG into joint-angle predictions driving an on-screen hand at 10 Hz. This demonstrated real-time reconstruction, although quantitative assessment of online control remains necessary. Main Results. In the primary within-participant offline evaluation, tangent-space features with LSTM performed best (Pearson r=0.90±0.08, MAE=0.08±0.04 rad, R 2 =0.79±0.15). Across decoders, tangent-space mapping improved over raw covariance (Holm-adjusted p=0.046). On NinaPro, the same combination achieved the highest correlation (r=0.742±0.055) and lowest normalized MAE (0.174±0.020), reproducing the tangent-space advantage (Holm-adjusted p=0.00036). The compact pipeline (157,332 parameters, 634.4 KB) had median prediction time of approximately 1 ms on tested hardware. Significance. Tangent-space covariance features improved offline decoding across datasets and decoders, with LSTM providing the strongest combination.
- 25 November 2026
- Published by IOP Publishing in Journal of Neural Engineering
Geometry matters in continuous EMG decoding: Comparing spatial representations across decoder architectures
Objective. Commercial myoelectric prostheses use discrete gesture classification and mode switching, limiting simultaneous and proportional hand control. Continuous surface electromyography (EMG) decoding offers a flexible alternative, but reconstruction remains challenging. Covariance matrices capture interchannel relationships, yet conventional decoders treat vectorized covariances as Euclidean features, disregarding manifold geometry. We investigated whether tangent-space projection improves continuous hand-kinematics decoding over raw covariance across decoder architectures. Approach. We compared raw covariance, tangent-space covariance and convolutional neural network features, each paired with linear regression, multilayer perceptron or long short-term memory (LSTM) decoders. The primary experiment decoded 20 joint angles from six-channel residual-limb EMG in four participants with transradial amputation, using tracked intact-hand movements as reference. To examine reproducibility across datasets, we repeated the comparison on NinaPro DB8, including 10 able-bodied participants and two with transradial amputation. Both evaluations were offline, with participant-specific training and testing. A separate exploratory online experiment used the primary EMG setup in two participants: one with a residual limb, one without upper-limb impairment. During attempted finger movements, the tangent-space and LSTM pipeline converted streaming EMG into joint-angle predictions driving an on-screen hand at 10 Hz. This demonstrated real-time reconstruction, although quantitative assessment of online control remains necessary. Main Results. In the primary within-participant offline evaluation, tangent-space features with LSTM performed best (Pearson r=0.90±0.08, MAE=0.08±0.04 rad, R 2 =0.79±0.15). Across decoders, tangent-space mapping improved over raw covariance (Holm-adjusted p=0.046). On NinaPro, the same combination achieved the highest correlation (r=0.742±0.055) and lowest normalized MAE (0.174±0.020), reproducing the tangent-space advantage (Holm-adjusted p=0.00036). The compact pipeline (157,332 parameters, 634.4 KB) had median prediction time of approximately 1 ms on tested hardware. Significance. Tangent-space covariance features improved offline decoding across datasets and decoders, with LSTM providing the strongest combination.
- Open Access
Tracking propagating cortical activity in MEG/EEG with a bilinear state-space model
Magnetoencephalography (MEG) and electroencephalography (EEG) are ideal for studying macroscopic neural dynamics, but non-invasive tracking of cortical traveling waves remains a major methodological challenge. Traditional inverse solutions assume spatiotemporal separability, restricting sources to fixed spatial to-pographies. Consequently, they struggle to capture the continuous spatial migration of cortical traveling waves and often misinterpret phase-locked static sources as spurious propagation. To address this fundamental limitation, we propose a dynamic state-space framework that explicitly accommodates the spatiotemporal inseparability of propagating neural activity. Our approach models the sensor signal as a bilinear combination of two states that evolve together: a fast, narrowband stochastic oscillator carrying the electrical time course, and a slowly evolving spatial topography that drifts through a data-driven singular value decomposition subspace. Both the rhythmic electrical time series and the migrating source trajectory track jointly via an Unscented Kalman Filter. We evaluated the method on realistically simulated MEG data and empirical resting-state MEG and EEG recordings targeting the occipital alpha rhythm. In simulations, the approach accurately recovered electrical time courses and spatial trajectories across varying signal-to-noise ratios, spatial envelope velocities up to 0.1 m/s, and distinct cortical geometries (calcarine and central sulci), significantly outperforming traditional minimum norm estimation and dipole fitting. Crucially, the model resists fabricating spurious propagation trajectories when presented with stationary, coherent dipoles. Application to empirical MEG and EEG recordings of the occipital alpha rhythm yields anatomically plausible, temporally cohesive propagation paths that explain significantly more sensor-level variance than static baselines. By embedding the evolving source geometry directly into the inverse solution, this framework provides a robust, proof-of-concept tool for the non-invasive investigation of macroscopic propagating brain dynamics.
Open AccessTracking propagating cortical activity in MEG/EEG with a bilinear state-space model
Magnetoencephalography (MEG) and electroencephalography (EEG) are ideal for studying macroscopic neural dynamics, but non-invasive tracking of cortical traveling waves remains a major methodological challenge. Traditional inverse solutions assume spatiotemporal separability, restricting sources to fixed spatial to-pographies. Consequently, they struggle to capture the continuous spatial migration of cortical traveling waves and often misinterpret phase-locked static sources as spurious propagation. To address this fundamental limitation, we propose a dynamic state-space framework that explicitly accommodates the spatiotemporal inseparability of propagating neural activity. Our approach models the sensor signal as a bilinear combination of two states that evolve together: a fast, narrowband stochastic oscillator carrying the electrical time course, and a slowly evolving spatial topography that drifts through a data-driven singular value decomposition subspace. Both the rhythmic electrical time series and the migrating source trajectory track jointly via an Unscented Kalman Filter. We evaluated the method on realistically simulated MEG data and empirical resting-state MEG and EEG recordings targeting the occipital alpha rhythm. In simulations, the approach accurately recovered electrical time courses and spatial trajectories across varying signal-to-noise ratios, spatial envelope velocities up to 0.1 m/s, and distinct cortical geometries (calcarine and central sulci), significantly outperforming traditional minimum norm estimation and dipole fitting. Crucially, the model resists fabricating spurious propagation trajectories when presented with stationary, coherent dipoles. Application to empirical MEG and EEG recordings of the occipital alpha rhythm yields anatomically plausible, temporally cohesive propagation paths that explain significantly more sensor-level variance than static baselines. By embedding the evolving source geometry directly into the inverse solution, this framework provides a robust, proof-of-concept tool for the non-invasive investigation of macroscopic propagating brain dynamics.
- Open Access
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 35-36
Poster: Geometry-Aware Real-Time Finger Decoding from Residual-Limb sEMG
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 35-36
Open AccessPoster: Geometry-Aware Real-Time Finger Decoding from Residual-Limb sEMG
- 28 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046031
A reliable and reproducible real-time access to sensorimotor rhythm with a small number of optically pumped magnetometers
Objective. Recent advances in biomagnetic sensing have led to the development of compact, wearable devices capable of detecting weak magnetic fields generated by biological activity. Optically pumped magnetometers (OPMs) have shown significant promise in functional neuroimaging. Brain rhythms play a crucial role in diagnostics, cognitive research, and neurointerfaces. Here we demonstrate that a small number of OPMs can reliably capture sensorimotor rhythms (SMRs). Approach. We conducted movement execution and motor imagery (MI) experiments with nine participants in two distinct magnetically shielded rooms (MSRs), each equipped with different ambient field suppression systems. We used only 4 OPMs located above the sensorimotor region and standard common-spatial-patterns (CSPs) based processing to decode the real and imaginary movement intentions of our participants. We evaluated reproducibility of the CSP components’ spectral profiles and assessed the decoding accuracy deterioration with reduction of OPM’s count. We also assessed the influence of the magnetic field orientation on the decoding accuracy and implemented a real-time MI brain–computer interface (BCI) solution. Main results. Under optimal conditions, OPM sensors deliver informative signals suitable for practical MI BCI applications. Those subjects who participated in the experiments in both MSRs exhibit highly reproducible SMR spectral patterns across two different magnetically shielded environments. The magnetic field components with radial orientation yield higher decoding accuracy than their tangential counterparts. In some subjects we observed more than 80% of binary decoding accuracy using a single OPM sensor. Finally we demonstrate real-time performance of our system along with clearly pronounced and behaviorally relevant fluctuations of the SMR power. Significance. For the first time, we demonstrated reliable and reproducible tracking of SMR components using a small number of contactless OPM sensors during movement execution and MI. Our findings pave the way for more efficient post-stroke neurorehabilitation by enabling MI-based BCI solutions to accelerate functional recovery.
- 28 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046031
A reliable and reproducible real-time access to sensorimotor rhythm with a small number of optically pumped magnetometers
Objective. Recent advances in biomagnetic sensing have led to the development of compact, wearable devices capable of detecting weak magnetic fields generated by biological activity. Optically pumped magnetometers (OPMs) have shown significant promise in functional neuroimaging. Brain rhythms play a crucial role in diagnostics, cognitive research, and neurointerfaces. Here we demonstrate that a small number of OPMs can reliably capture sensorimotor rhythms (SMRs). Approach. We conducted movement execution and motor imagery (MI) experiments with nine participants in two distinct magnetically shielded rooms (MSRs), each equipped with different ambient field suppression systems. We used only 4 OPMs located above the sensorimotor region and standard common-spatial-patterns (CSPs) based processing to decode the real and imaginary movement intentions of our participants. We evaluated reproducibility of the CSP components’ spectral profiles and assessed the decoding accuracy deterioration with reduction of OPM’s count. We also assessed the influence of the magnetic field orientation on the decoding accuracy and implemented a real-time MI brain–computer interface (BCI) solution. Main results. Under optimal conditions, OPM sensors deliver informative signals suitable for practical MI BCI applications. Those subjects who participated in the experiments in both MSRs exhibit highly reproducible SMR spectral patterns across two different magnetically shielded environments. The magnetic field components with radial orientation yield higher decoding accuracy than their tangential counterparts. In some subjects we observed more than 80% of binary decoding accuracy using a single OPM sensor. Finally we demonstrate real-time performance of our system along with clearly pronounced and behaviorally relevant fluctuations of the SMR power. Significance. For the first time, we demonstrated reliable and reproducible tracking of SMR components using a small number of contactless OPM sensors during movement execution and MI. Our findings pave the way for more efficient post-stroke neurorehabilitation by enabling MI-based BCI solutions to accelerate functional recovery.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
The Tale of Two Rooms: Comparison of QuSpin Zero-Field OPMs’ Operation in Two Magnetically Shielded Environments
This paper addresses several critical aspects of using optically pumped magnetometers (OPMs), focusing on both metrological issues and the enhancement of signal quality. We present a quantitative methodology for OPM measurements standardization and quality evaluation, which is crucial in biomedical applications like magnetoencephalography (MEG). Additionally, we introduce a novel, cost-effective portable active magnetic shielding system - digital adaptive suppression system (DASS) – that represents a significant advancement over traditional analog active shielding. Through comprehensive experimental research, we evaluate first-and third-generation commercial OPMs from QuSpin Inc. in two distinct magnetic environments. Our results demonstrate that the DASS ensures optimal and reliable OPM performance, even in noisy urban settings, surpassing the effectiveness of conventional analog shielding. These findings highlight the need for advanced magnetic shielding solutions to enhance the accuracy and reproducibility of OPM measurements.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
The Tale of Two Rooms: Comparison of QuSpin Zero-Field OPMs’ Operation in Two Magnetically Shielded Environments
This paper addresses several critical aspects of using optically pumped magnetometers (OPMs), focusing on both metrological issues and the enhancement of signal quality. We present a quantitative methodology for OPM measurements standardization and quality evaluation, which is crucial in biomedical applications like magnetoencephalography (MEG). Additionally, we introduce a novel, cost-effective portable active magnetic shielding system - digital adaptive suppression system (DASS) – that represents a significant advancement over traditional analog active shielding. Through comprehensive experimental research, we evaluate first-and third-generation commercial OPMs from QuSpin Inc. in two distinct magnetic environments. Our results demonstrate that the DASS ensures optimal and reliable OPM performance, even in noisy urban settings, surpassing the effectiveness of conventional analog shielding. These findings highlight the need for advanced magnetic shielding solutions to enhance the accuracy and reproducibility of OPM measurements.
- 31 December 2024
- Published by Springer Nature
- p. 179-191
Epistemic Value Anticipation into the Deep Active Inference Model
- 31 December 2024
- Published by Springer Nature
- p. 179-191
Epistemic Value Anticipation into the Deep Active Inference Model
- Open Access
Low count of optically pumped magnetometers furnishes a reliable real-time access to sensorimotor rhythm
This study presents an analysis of sensorimotor rhythms using an advanced, optically-pumped magnetoencephalography (OPM-MEG) system - a novel and rapidly developing technology. We conducted real-movement and motor imagery experiments with nine participants across two distinct magnetically-shielded environments: one featuring an analog active suppression system and the other a digital implementation. Our findings demonstrate that, under optimal recording conditions, OPM sensors provide highly informative signals, suitable for use in practical motor imagery brain-computer interface (BCI) applications. We further examine the feasibility of a portable, low-sensor-count OPM-based BCI under varied experimental setups, highlighting its potential for real-time control of external devices via user intentions.
Open AccessLow count of optically pumped magnetometers furnishes a reliable real-time access to sensorimotor rhythm
This study presents an analysis of sensorimotor rhythms using an advanced, optically-pumped magnetoencephalography (OPM-MEG) system - a novel and rapidly developing technology. We conducted real-movement and motor imagery experiments with nine participants across two distinct magnetically-shielded environments: one featuring an analog active suppression system and the other a digital implementation. Our findings demonstrate that, under optimal recording conditions, OPM sensors provide highly informative signals, suitable for use in practical motor imagery brain-computer interface (BCI) applications. We further examine the feasibility of a portable, low-sensor-count OPM-based BCI under varied experimental setups, highlighting its potential for real-time control of external devices via user intentions.
- Open Access
Hardware-Powered Ultra Low Latency (HarPULL) Brain State Dependent TMS Technology
Objective Upcoming neuroscientific research will depend significantly on tools enabling bidirectional and context dependent interaction with nervous tissue, whether through invasive or non-invasive means, targeting specific neural regions, the entire brain, or functional networks. To facilitate the associated future neuroscientific discoveries we have created HarPULL, a genuinely real-time system that tracks oscillatory brain state and can be coupled with a range of feedback and stimulation devices to close the interactive loop in a precise and brain state dependent manner. Approach The HarPULL technology ensures reliable and accurate real-time phase tracking based on the framework of the state-space estimation techniques operationalized by Kalman filtering for optimal tracking of the complex valued analytic signal associated with the target brain rhythm. To avoid data transfer delays and to obtain a truly real-time system the algorithm is implemented on the computational core of an EEG amplifier controlled by a real-time operation system. Real and imaginary parts of the analytic signal furnish direct access to the instantaneous phase and amplitude of the brain rhythm. Systems performance is tested with simulated and real data both online and offline as well as within a real-time state dependent TMS using a phantom and human subjects. Main results We augment the existing literature by inscribing the steady-state Kalman filters into the oscillatory brain state estimation framework. We also show that taking into account the 1/f nature of the brain noise and the use of the steady state colored Kalman filter further improves phase tracking performance in both simulated and real data. We implement our real-time phase tracking algorithms on board of an EEG device and use it to trigger the TMS device contingent upon the target phase. We demonstrate minimal delay (2 ms) between the occurrence of the predetermined rhythm phase in the cortex and the corresponding magnetic stimulus. Also, using this setup in a real-time setting we observe a significant modulation of the motor evoked potentials (MEP) by the sensorimotor rhythm’s phase. Finally, using our HarPULL technology, for the first time in real-time we obtain muscle cortical representation (MCR) maps for different target phase values. The acquired MCRs appear to be clearly dependent on the phase value. TMS during the excitation state consistently producing nearly 50% greater MEP amplitudes over the entire map as compared to the inhibitory state responses. We have also observed better delineation between the representations of several muscles when the stimulation is performed in the excitation state. Significance HarPULL is the first technology for the instantaneous tracking of the brain’s rhythmic activity and operating exclusively on the truly real-time computational core furnished by a digital EEG device. The algorithmic core capable of tracking both phase and the instantaneous rhythm power boosts specificity of the associated magnetic stimulation and potentially other forms of brain-state contingent feedback signals. Our technological solution establishes a real-time nearly instantaneous non-invasive contact with a living brain which has a broad range of clinical and scientific applications.
Open AccessHardware-Powered Ultra Low Latency (HarPULL) Brain State Dependent TMS Technology
Objective Upcoming neuroscientific research will depend significantly on tools enabling bidirectional and context dependent interaction with nervous tissue, whether through invasive or non-invasive means, targeting specific neural regions, the entire brain, or functional networks. To facilitate the associated future neuroscientific discoveries we have created HarPULL, a genuinely real-time system that tracks oscillatory brain state and can be coupled with a range of feedback and stimulation devices to close the interactive loop in a precise and brain state dependent manner. Approach The HarPULL technology ensures reliable and accurate real-time phase tracking based on the framework of the state-space estimation techniques operationalized by Kalman filtering for optimal tracking of the complex valued analytic signal associated with the target brain rhythm. To avoid data transfer delays and to obtain a truly real-time system the algorithm is implemented on the computational core of an EEG amplifier controlled by a real-time operation system. Real and imaginary parts of the analytic signal furnish direct access to the instantaneous phase and amplitude of the brain rhythm. Systems performance is tested with simulated and real data both online and offline as well as within a real-time state dependent TMS using a phantom and human subjects. Main results We augment the existing literature by inscribing the steady-state Kalman filters into the oscillatory brain state estimation framework. We also show that taking into account the 1/f nature of the brain noise and the use of the steady state colored Kalman filter further improves phase tracking performance in both simulated and real data. We implement our real-time phase tracking algorithms on board of an EEG device and use it to trigger the TMS device contingent upon the target phase. We demonstrate minimal delay (2 ms) between the occurrence of the predetermined rhythm phase in the cortex and the corresponding magnetic stimulus. Also, using this setup in a real-time setting we observe a significant modulation of the motor evoked potentials (MEP) by the sensorimotor rhythm’s phase. Finally, using our HarPULL technology, for the first time in real-time we obtain muscle cortical representation (MCR) maps for different target phase values. The acquired MCRs appear to be clearly dependent on the phase value. TMS during the excitation state consistently producing nearly 50% greater MEP amplitudes over the entire map as compared to the inhibitory state responses. We have also observed better delineation between the representations of several muscles when the stimulation is performed in the excitation state. Significance HarPULL is the first technology for the instantaneous tracking of the brain’s rhythmic activity and operating exclusively on the truly real-time computational core furnished by a digital EEG device. The algorithmic core capable of tracking both phase and the instantaneous rhythm power boosts specificity of the associated magnetic stimulation and potentially other forms of brain-state contingent feedback signals. Our technological solution establishes a real-time nearly instantaneous non-invasive contact with a living brain which has a broad range of clinical and scientific applications.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 180-188
Optically Pumped Magnetometers in the MEG-Research at the Higher School of Economics
Magnetoencephalography (MEG) is a powerful method for imaging brain activity, with superior spatial resolution compared to electroencephalography (EEG). Superconducting quantum interference device (SQUID)-based systems are mostly used for MEG-acquisition, but they come with limitations like sensor-to-scalp distance and high ownership costs. Optically pumped magnetometers (OPM) sensors are emerging as alternatives, overcoming these issues. We conducted comprehensive research using commercially available OPM sensors QuSpin Gen-2 to explore sensorimotor rhythm within motor-imagery brain-computer interface (BCI) applications. Our study reveals the expected influence of sensor location on signal quality and highlights the feasibility of single-sensor motor-imagery BCIs. We demonstrate OPM sensors' advantages over SQUID-based MEG and describe a preliminary version of the adaptive remnant filed compensation system to mitigate low frequency environmental magnetic noise.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 180-188
Optically Pumped Magnetometers in the MEG-Research at the Higher School of Economics
Magnetoencephalography (MEG) is a powerful method for imaging brain activity, with superior spatial resolution compared to electroencephalography (EEG). Superconducting quantum interference device (SQUID)-based systems are mostly used for MEG-acquisition, but they come with limitations like sensor-to-scalp distance and high ownership costs. Optically pumped magnetometers (OPM) sensors are emerging as alternatives, overcoming these issues. We conducted comprehensive research using commercially available OPM sensors QuSpin Gen-2 to explore sensorimotor rhythm within motor-imagery brain-computer interface (BCI) applications. Our study reveals the expected influence of sensor location on signal quality and highlights the feasibility of single-sensor motor-imagery BCIs. We demonstrate OPM sensors' advantages over SQUID-based MEG and describe a preliminary version of the adaptive remnant filed compensation system to mitigate low frequency environmental magnetic noise.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 189-195
Hardware Powered Ultra Low Latency (HarPULL) Brain-State Dependent TMS Technology
The paper introduces a novel hardware-software complex for the low latency real time phase-dependent transcranial magnetic stimulation (TMS) neurofeedback. The software with key elements implemented on the board of the EEG-recording device accurately tracks the sensorimotor rhythm phase with minimal time-delay and immediately sends the trigger to the TMS-device. An accurate phase estimation is achieved by proper Kalman filter-based state-space modeling of brain rhythm. Our experiments demonstrate the system's viability and its almost instant reaction on the target brain event occurrence. Our results potentially make neurofeedback, cortical mapping, therapeutic TMS-interventions and other applications more reliable and efficient.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 189-195
Hardware Powered Ultra Low Latency (HarPULL) Brain-State Dependent TMS Technology
The paper introduces a novel hardware-software complex for the low latency real time phase-dependent transcranial magnetic stimulation (TMS) neurofeedback. The software with key elements implemented on the board of the EEG-recording device accurately tracks the sensorimotor rhythm phase with minimal time-delay and immediately sends the trigger to the TMS-device. An accurate phase estimation is achieved by proper Kalman filter-based state-space modeling of brain rhythm. Our experiments demonstrate the system's viability and its almost instant reaction on the target brain event occurrence. Our results potentially make neurofeedback, cortical mapping, therapeutic TMS-interventions and other applications more reliable and efficient.