Daria Medvedeva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daria Medvedeva has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alexei Ossadtchi
HSE University, Moscow, Russian Federation and AXXX, Moscow, Russian Federation
6 shared publications - Nikita Fedosov
Centre for Bioelectric interfaces, Higher School of Economics, Moscow, Russia
5 shared publications Oleg Shevtsov
Centre for Bioelectric Interfaces Higher School of Economics, LLC, Life Improvement by Future Technologies Institute,Moscow,Russia
2 shared publications- Oleg Shevtsov
Centre for Cognition and Decision making, Institute for Cognitive Neuroscience, National Research University “Higher School of economics
2 shared publications Uliya Nekrasova
Center for Cybernetic Medicine and Neuroprosthetics, Moscow, Russian Federation
2 shared publications- Anna Butorina
Skolkovo Institute of Science and Technology, Moscow, Russia
1 shared publication
Latest Publications
- Open Access
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 35-36
Poster: Geometry-Aware Real-Time Finger Decoding from Residual-Limb sEMG
- 20 June 2026
- Published by Association for Computing Machinery (ACM)
- p. 35-36
Open AccessPoster: Geometry-Aware Real-Time Finger Decoding from Residual-Limb sEMG
- 28 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046031
A reliable and reproducible real-time access to sensorimotor rhythm with a small number of optically pumped magnetometers
Objective. Recent advances in biomagnetic sensing have led to the development of compact, wearable devices capable of detecting weak magnetic fields generated by biological activity. Optically pumped magnetometers (OPMs) have shown significant promise in functional neuroimaging. Brain rhythms play a crucial role in diagnostics, cognitive research, and neurointerfaces. Here we demonstrate that a small number of OPMs can reliably capture sensorimotor rhythms (SMRs). Approach. We conducted movement execution and motor imagery (MI) experiments with nine participants in two distinct magnetically shielded rooms (MSRs), each equipped with different ambient field suppression systems. We used only 4 OPMs located above the sensorimotor region and standard common-spatial-patterns (CSPs) based processing to decode the real and imaginary movement intentions of our participants. We evaluated reproducibility of the CSP components’ spectral profiles and assessed the decoding accuracy deterioration with reduction of OPM’s count. We also assessed the influence of the magnetic field orientation on the decoding accuracy and implemented a real-time MI brain–computer interface (BCI) solution. Main results. Under optimal conditions, OPM sensors deliver informative signals suitable for practical MI BCI applications. Those subjects who participated in the experiments in both MSRs exhibit highly reproducible SMR spectral patterns across two different magnetically shielded environments. The magnetic field components with radial orientation yield higher decoding accuracy than their tangential counterparts. In some subjects we observed more than 80% of binary decoding accuracy using a single OPM sensor. Finally we demonstrate real-time performance of our system along with clearly pronounced and behaviorally relevant fluctuations of the SMR power. Significance. For the first time, we demonstrated reliable and reproducible tracking of SMR components using a small number of contactless OPM sensors during movement execution and MI. Our findings pave the way for more efficient post-stroke neurorehabilitation by enabling MI-based BCI solutions to accelerate functional recovery.
- 28 July 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (4) , 046031
A reliable and reproducible real-time access to sensorimotor rhythm with a small number of optically pumped magnetometers
Objective. Recent advances in biomagnetic sensing have led to the development of compact, wearable devices capable of detecting weak magnetic fields generated by biological activity. Optically pumped magnetometers (OPMs) have shown significant promise in functional neuroimaging. Brain rhythms play a crucial role in diagnostics, cognitive research, and neurointerfaces. Here we demonstrate that a small number of OPMs can reliably capture sensorimotor rhythms (SMRs). Approach. We conducted movement execution and motor imagery (MI) experiments with nine participants in two distinct magnetically shielded rooms (MSRs), each equipped with different ambient field suppression systems. We used only 4 OPMs located above the sensorimotor region and standard common-spatial-patterns (CSPs) based processing to decode the real and imaginary movement intentions of our participants. We evaluated reproducibility of the CSP components’ spectral profiles and assessed the decoding accuracy deterioration with reduction of OPM’s count. We also assessed the influence of the magnetic field orientation on the decoding accuracy and implemented a real-time MI brain–computer interface (BCI) solution. Main results. Under optimal conditions, OPM sensors deliver informative signals suitable for practical MI BCI applications. Those subjects who participated in the experiments in both MSRs exhibit highly reproducible SMR spectral patterns across two different magnetically shielded environments. The magnetic field components with radial orientation yield higher decoding accuracy than their tangential counterparts. In some subjects we observed more than 80% of binary decoding accuracy using a single OPM sensor. Finally we demonstrate real-time performance of our system along with clearly pronounced and behaviorally relevant fluctuations of the SMR power. Significance. For the first time, we demonstrated reliable and reproducible tracking of SMR components using a small number of contactless OPM sensors during movement execution and MI. Our findings pave the way for more efficient post-stroke neurorehabilitation by enabling MI-based BCI solutions to accelerate functional recovery.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
The Tale of Two Rooms: Comparison of QuSpin Zero-Field OPMs’ Operation in Two Magnetically Shielded Environments
This paper addresses several critical aspects of using optically pumped magnetometers (OPMs), focusing on both metrological issues and the enhancement of signal quality. We present a quantitative methodology for OPM measurements standardization and quality evaluation, which is crucial in biomedical applications like magnetoencephalography (MEG). Additionally, we introduce a novel, cost-effective portable active magnetic shielding system - digital adaptive suppression system (DASS) – that represents a significant advancement over traditional analog active shielding. Through comprehensive experimental research, we evaluate first-and third-generation commercial OPMs from QuSpin Inc. in two distinct magnetic environments. Our results demonstrate that the DASS ensures optimal and reliable OPM performance, even in noisy urban settings, surpassing the effectiveness of conventional analog shielding. These findings highlight the need for advanced magnetic shielding solutions to enhance the accuracy and reproducibility of OPM measurements.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
The Tale of Two Rooms: Comparison of QuSpin Zero-Field OPMs’ Operation in Two Magnetically Shielded Environments
This paper addresses several critical aspects of using optically pumped magnetometers (OPMs), focusing on both metrological issues and the enhancement of signal quality. We present a quantitative methodology for OPM measurements standardization and quality evaluation, which is crucial in biomedical applications like magnetoencephalography (MEG). Additionally, we introduce a novel, cost-effective portable active magnetic shielding system - digital adaptive suppression system (DASS) – that represents a significant advancement over traditional analog active shielding. Through comprehensive experimental research, we evaluate first-and third-generation commercial OPMs from QuSpin Inc. in two distinct magnetic environments. Our results demonstrate that the DASS ensures optimal and reliable OPM performance, even in noisy urban settings, surpassing the effectiveness of conventional analog shielding. These findings highlight the need for advanced magnetic shielding solutions to enhance the accuracy and reproducibility of OPM measurements.
- Open Access
- 16 October 2024
- Published by IOS Press
- p. 4467-4470
AI-Powered Virtual Reality System for Training Wrist Amputees to Use Advanced Prosthetic Solutions
Individuals with upper limb amputations or congenital defects face substantial challenges in performing daily tasks, often exacerbated by limited functionality in the existing bionic prostheses. To address this, we present an AI-powered virtual reality (VR) system designed to train patients to control bionic prostheses with a high number of degrees of freedom using electromyographic (EMG) activity decoding. Current prosthetic control systems lack sophistication, relying on discrete muscle activity decoding and manual mode switching. Our system employs a novel neural network architecture pre-trained on healthy subjects, facilitating continuous decoding of residual muscle activity to control a virtual limb in the VR. Through three months of training, participants with congenital upper limb dysplasia achieved precise finger-specific control, demonstrating a low error rate and strong correlation between the target and the decoded kinematics. Importantly, the system’s adaptability and its user-friendly interface positively impacted patient experience, offering potential reduction of muscle atrophy risks and psychological benefits while preparing individuals for the use of an advanced prosthetic device. This innovative approach represents a significant step toward enhancing prosthetic functionality and improving the quality of life for upper limb amputees and congenital defect patients.
- 16 October 2024
- Published by IOS Press
- p. 4467-4470
Open AccessAI-Powered Virtual Reality System for Training Wrist Amputees to Use Advanced Prosthetic Solutions
Individuals with upper limb amputations or congenital defects face substantial challenges in performing daily tasks, often exacerbated by limited functionality in the existing bionic prostheses. To address this, we present an AI-powered virtual reality (VR) system designed to train patients to control bionic prostheses with a high number of degrees of freedom using electromyographic (EMG) activity decoding. Current prosthetic control systems lack sophistication, relying on discrete muscle activity decoding and manual mode switching. Our system employs a novel neural network architecture pre-trained on healthy subjects, facilitating continuous decoding of residual muscle activity to control a virtual limb in the VR. Through three months of training, participants with congenital upper limb dysplasia achieved precise finger-specific control, demonstrating a low error rate and strong correlation between the target and the decoded kinematics. Importantly, the system’s adaptability and its user-friendly interface positively impacted patient experience, offering potential reduction of muscle atrophy risks and psychological benefits while preparing individuals for the use of an advanced prosthetic device. This innovative approach represents a significant step toward enhancing prosthetic functionality and improving the quality of life for upper limb amputees and congenital defect patients.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 180-188
Optically Pumped Magnetometers in the MEG-Research at the Higher School of Economics
Magnetoencephalography (MEG) is a powerful method for imaging brain activity, with superior spatial resolution compared to electroencephalography (EEG). Superconducting quantum interference device (SQUID)-based systems are mostly used for MEG-acquisition, but they come with limitations like sensor-to-scalp distance and high ownership costs. Optically pumped magnetometers (OPM) sensors are emerging as alternatives, overcoming these issues. We conducted comprehensive research using commercially available OPM sensors QuSpin Gen-2 to explore sensorimotor rhythm within motor-imagery brain-computer interface (BCI) applications. Our study reveals the expected influence of sensor location on signal quality and highlights the feasibility of single-sensor motor-imagery BCIs. We demonstrate OPM sensors' advantages over SQUID-based MEG and describe a preliminary version of the adaptive remnant filed compensation system to mitigate low frequency environmental magnetic noise.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 180-188
Optically Pumped Magnetometers in the MEG-Research at the Higher School of Economics
Magnetoencephalography (MEG) is a powerful method for imaging brain activity, with superior spatial resolution compared to electroencephalography (EEG). Superconducting quantum interference device (SQUID)-based systems are mostly used for MEG-acquisition, but they come with limitations like sensor-to-scalp distance and high ownership costs. Optically pumped magnetometers (OPM) sensors are emerging as alternatives, overcoming these issues. We conducted comprehensive research using commercially available OPM sensors QuSpin Gen-2 to explore sensorimotor rhythm within motor-imagery brain-computer interface (BCI) applications. Our study reveals the expected influence of sensor location on signal quality and highlights the feasibility of single-sensor motor-imagery BCIs. We demonstrate OPM sensors' advantages over SQUID-based MEG and describe a preliminary version of the adaptive remnant filed compensation system to mitigate low frequency environmental magnetic noise.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 189-195
Hardware Powered Ultra Low Latency (HarPULL) Brain-State Dependent TMS Technology
The paper introduces a novel hardware-software complex for the low latency real time phase-dependent transcranial magnetic stimulation (TMS) neurofeedback. The software with key elements implemented on the board of the EEG-recording device accurately tracks the sensorimotor rhythm phase with minimal time-delay and immediately sends the trigger to the TMS-device. An accurate phase estimation is achieved by proper Kalman filter-based state-space modeling of brain rhythm. Our experiments demonstrate the system's viability and its almost instant reaction on the target brain event occurrence. Our results potentially make neurofeedback, cortical mapping, therapeutic TMS-interventions and other applications more reliable and efficient.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 189-195
Hardware Powered Ultra Low Latency (HarPULL) Brain-State Dependent TMS Technology
The paper introduces a novel hardware-software complex for the low latency real time phase-dependent transcranial magnetic stimulation (TMS) neurofeedback. The software with key elements implemented on the board of the EEG-recording device accurately tracks the sensorimotor rhythm phase with minimal time-delay and immediately sends the trigger to the TMS-device. An accurate phase estimation is achieved by proper Kalman filter-based state-space modeling of brain rhythm. Our experiments demonstrate the system's viability and its almost instant reaction on the target brain event occurrence. Our results potentially make neurofeedback, cortical mapping, therapeutic TMS-interventions and other applications more reliable and efficient.