Jiaming Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaming Lv has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jiapei Li
School of Automation and Information Engineering, Xi’an University of Technology , Xi’an, China
1 shared publication - Jiaying Zhang
School of Xi’an University of Technology, Xi’an 710048, People’s Republic of China
1 shared publication - Jintong Li
School of Xi’an University of Technology, Xi’an 710048, People’s Republic of China
1 shared publication - Qing Liu
School of Automation and Information Engineering, Xi'an University of Technology, Xi'an, China
1 shared publication - Ting Shang
National and Local Engineering Research Center of Crystal Growth Equipment and System Integration
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (9)
A fast calibration method for distributed measurement systems
Aiming at the distributed measurement system multi-equipment coordinated measurement, the data measured by each transmitting station are unified under a common coordinate system, which has the problems of complicated operation and high time and cost. In this paper, a fast calibration method for distributed measurement systems based on standard devices is proposed. The method designs a new type of architectural calibration board with non-coplanar measurement nodes, calculates the coordinates of the measurement nodes using geometric relations, solves the initial values of the system parameters, and substitutes the initial values into the L-M least squares algorithm for iterative optimization so that it only needs to carry out one scanning measurement for each reference position in the calibration process to complete the calibration. We designed an experiment in which a distributed measurement system consisting of four transmitting stations measured three standard rods (1650.073, 1156.704, and 875.950 mm) sequentially after calibration in a measuring space of 5 × 5 × 3 m3. The experimental results show that under the premise of ensuring that the measurement accuracy is better than 0.20 mm, the calibration of the parameters of the distributed measurement system can be completed within 20 min.
- 1 September 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (9)
Open AccessA fast calibration method for distributed measurement systems
Aiming at the distributed measurement system multi-equipment coordinated measurement, the data measured by each transmitting station are unified under a common coordinate system, which has the problems of complicated operation and high time and cost. In this paper, a fast calibration method for distributed measurement systems based on standard devices is proposed. The method designs a new type of architectural calibration board with non-coplanar measurement nodes, calculates the coordinates of the measurement nodes using geometric relations, solves the initial values of the system parameters, and substitutes the initial values into the L-M least squares algorithm for iterative optimization so that it only needs to carry out one scanning measurement for each reference position in the calibration process to complete the calibration. We designed an experiment in which a distributed measurement system consisting of four transmitting stations measured three standard rods (1650.073, 1156.704, and 875.950 mm) sequentially after calibration in a measuring space of 5 × 5 × 3 m3. The experimental results show that under the premise of ensuring that the measurement accuracy is better than 0.20 mm, the calibration of the parameters of the distributed measurement system can be completed within 20 min.