TSTing Shang

Ting Shang

*This is an algorithmically generated author record based on publicly available information.

Ting Shang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prediction of Fatigue Crack Propagation in X80 Pipeline Steel Using Acoustic Emission Sensing

    by Yan Yan, Wei Liu, Yuanhang Gong, Xiaohui Zhang, Ting Shang, Jiaqi Pei, Bin Gao, Xin Li

    Fatigue cracks in gas pipelines, particularly those constructed from X80 steel, pose significant risks of catastrophic failure if not monitored continuously. This study presents a novel methodology for predicting the Fatigue Crack Propagation Rate (FCPR) of X80 pipeline steel by using Acoustic Emission (AE) sensing technique. Through a series of three-point bending fatigue tests conducted under varying loading conditions, the influence of the stress ratio and maximum load on the fatigue crack propagation behavior of X80 pipeline steel is investigated. Furthermore, the characteristics of AE signals generated during the stable and rapid crack propagation stages has been analyzed. A new AE feature, related to the average AE amplitude rate, is proposed, demonstrating a stronger linear correlation with FCPR than traditional AE feature metrics. Based on this newly proposed AE feature, a predictive model for fatigue crack propagation has been developed, which not only accurately identifies the transition from stable to rapid crack propagation but also offers precise real-time predictions of FCPR, with predictions falling within the 95% confidence interval of measured values. These findings offer a robust framework for real-time structural health monitoring of pipelines, enhancing early intervention strategies and improving safety protocols for critical pipeline infrastructure.


  • Open Access

    A fast calibration method for distributed measurement systems

    by Qing Liu, Jiaming Lv, Jiaying Zhang, Jintong Li, Jiapei Li, Ting Shang

    Aiming at the distributed measurement system multi-equipment coordinated measurement, the data measured by each transmitting station are unified under a common coordinate system, which has the problems of complicated operation and high time and cost. In this paper, a fast calibration method for distributed measurement systems based on standard devices is proposed. The method designs a new type of architectural calibration board with non-coplanar measurement nodes, calculates the coordinates of the measurement nodes using geometric relations, solves the initial values of the system parameters, and substitutes the initial values into the L-M least squares algorithm for iterative optimization so that it only needs to carry out one scanning measurement for each reference position in the calibration process to complete the calibration. We designed an experiment in which a distributed measurement system consisting of four transmitting stations measured three standard rods (1650.073, 1156.704, and 875.950 mm) sequentially after calibration in a measuring space of 5 × 5 × 3 m3. The experimental results show that under the premise of ensuring that the measurement accuracy is better than 0.20 mm, the calibration of the parameters of the distributed measurement system can be completed within 20 min.