Fenna Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fenna Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Bin Wang
College of Mechanical and Electronic Engineering China University of Petroleum (East China) Qingdao China
2 shared publications - Chuankai Jing
College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao 266580, China
2 shared publications - Fenna Zhang
College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao 266580, China
1 shared publication - Hao Hu
China United Coalbed Methane Corporation Ltd., Beijing 100015, China
1 shared publication - Hongying Zhu
College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao 266000, China
1 shared publication - Jia Li
College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao 266580, China
1 shared publication
Latest Publications
- Open Access
Low-Frequency Corrosion Fatigue Test Study of Sucker Rods under High-Salinity Well Fluids in Deep CBM Wells
Corrosion fatigue test is the most direct and effective method to study the corrosion fatigue characteristics of sucker rod. At present, the commonly used test method is the high frequency fatigue test, but the working state of sucker rod is typical low-frequency and high-cycle corrosion fatigue, and the test with high frequency will reduce the impact of corrosion. Alloy steel 4330 is widely used in coalbed gas well high strength sucker rod, but the research on its low frequency corrosion fatigue life is relatively few. Therefore, in this paper, the corrosion fatigue test method of axial low-frequency and high-cycle was adopted to study the corrosion fatigue characteristics of 4330 steel sucker rod through the corrosion fatigue test under different typical corrosion media, temperature, and stress levels. The results show that the fatigue life of 4330 sucker rod drops sharply when the Cl− concentration in high salinity well fluid exceeds the threshold value of 155 mg/L. When this threshold is exceeded, the downward trend slows down. It can be seen that the significant factor affecting the corrosion fatigue life of 4330 material is not the concentration of Cl−, but the existence of Cl−. The presence of HCO3− promotes a further decrease in the corrosion fatigue life of the 4330 sucker rod by Cl−. The corrosion fatigue life of 4330 sucker rod decreases with the increase of temperature. When the well fluid temperature is less than 50 °C, the impact is relatively significant. When the well fluid temperature is more than 70 °C, the decline trend of corrosion fatigue life slows down. Based on the fitted S-N curve (stress-fatigue life curve), it is calculated that the fatigue limit of 4330 sucker rod at the stress ratio of 0.6 is 196 MPa in the solution of 10,000 mg/L Cl− at room temperature. These could provide valuable theoretical and technical guidance for design and selection of high-strength sucker rod in high-salinity corrosion well fluid environment.
Open AccessLow-Frequency Corrosion Fatigue Test Study of Sucker Rods under High-Salinity Well Fluids in Deep CBM Wells
Corrosion fatigue test is the most direct and effective method to study the corrosion fatigue characteristics of sucker rod. At present, the commonly used test method is the high frequency fatigue test, but the working state of sucker rod is typical low-frequency and high-cycle corrosion fatigue, and the test with high frequency will reduce the impact of corrosion. Alloy steel 4330 is widely used in coalbed gas well high strength sucker rod, but the research on its low frequency corrosion fatigue life is relatively few. Therefore, in this paper, the corrosion fatigue test method of axial low-frequency and high-cycle was adopted to study the corrosion fatigue characteristics of 4330 steel sucker rod through the corrosion fatigue test under different typical corrosion media, temperature, and stress levels. The results show that the fatigue life of 4330 sucker rod drops sharply when the Cl− concentration in high salinity well fluid exceeds the threshold value of 155 mg/L. When this threshold is exceeded, the downward trend slows down. It can be seen that the significant factor affecting the corrosion fatigue life of 4330 material is not the concentration of Cl−, but the existence of Cl−. The presence of HCO3− promotes a further decrease in the corrosion fatigue life of the 4330 sucker rod by Cl−. The corrosion fatigue life of 4330 sucker rod decreases with the increase of temperature. When the well fluid temperature is less than 50 °C, the impact is relatively significant. When the well fluid temperature is more than 70 °C, the decline trend of corrosion fatigue life slows down. Based on the fitted S-N curve (stress-fatigue life curve), it is calculated that the fatigue limit of 4330 sucker rod at the stress ratio of 0.6 is 196 MPa in the solution of 10,000 mg/L Cl− at room temperature. These could provide valuable theoretical and technical guidance for design and selection of high-strength sucker rod in high-salinity corrosion well fluid environment.
- Open Access
Study on Variable Stress Corrosion Susceptibility of Four Typical High-Strength Sucker Rods in High-Salinity Well Fluids
To study the corrosion characteristics of high-strength sucker rods in high-salinity well fluids under alternating stresses, a single-factor stress corrosion test was designed. The slow strain rate tensile test (SSRT) was carried out for four kinds of high-strength sucker rods under different Cl− and HCO3− concentrations and with different service strengths, and the variable stress corrosion cracking susceptibility was analyzed. The results show that the elongation loss and absorbed work loss of the H-grade ultra-high-strength 4330 sucker rod after stress corrosion are greater than those of both the high-strength 4142 sucker rod and the high-strength 20CrMoA sucker rod. The elongation and absorbed work loss of the 30CrMoA and 20CrMoA sucker rods are less affected by the changes in Cl− and HCO3−. With the increase in use strength, the elongation and absorbed work loss of the high-strength sucker rod increase. The change in the surface of the sucker rod during the corrosion process is inconsistent with the actual elongation of the sucker rod and the absorbed work loss. It can be concluded that the stress corrosion cracking susceptibility of the sucker rod is not necessarily related to the tensile strength of the sucker rod. The 4330 sucker rod is not suitable for applications in wells with a high concentration of Cl−, but it is suitable for operation in alkaline conditions where corrosive media such as HCO3− and Cl− coexist. Under highly corrosive and highly mineralized conditions, the 30CrMoA sucker rod is less susceptible to stress corrosion. The stress corrosion cracking susceptibility of the 20CrMoA sucker rod is lower than that of the 4142 sucker rod. In high-salinity well fluids, the higher the use strength, the higher the stress corrosion cracking susceptibility of the high-strength sucker rod is. The test results for the weight-loss-based corrosion rate and plastic loss may contradict the determination of the corrosion susceptibility of the material under working conditions.
Open AccessStudy on Variable Stress Corrosion Susceptibility of Four Typical High-Strength Sucker Rods in High-Salinity Well Fluids
To study the corrosion characteristics of high-strength sucker rods in high-salinity well fluids under alternating stresses, a single-factor stress corrosion test was designed. The slow strain rate tensile test (SSRT) was carried out for four kinds of high-strength sucker rods under different Cl− and HCO3− concentrations and with different service strengths, and the variable stress corrosion cracking susceptibility was analyzed. The results show that the elongation loss and absorbed work loss of the H-grade ultra-high-strength 4330 sucker rod after stress corrosion are greater than those of both the high-strength 4142 sucker rod and the high-strength 20CrMoA sucker rod. The elongation and absorbed work loss of the 30CrMoA and 20CrMoA sucker rods are less affected by the changes in Cl− and HCO3−. With the increase in use strength, the elongation and absorbed work loss of the high-strength sucker rod increase. The change in the surface of the sucker rod during the corrosion process is inconsistent with the actual elongation of the sucker rod and the absorbed work loss. It can be concluded that the stress corrosion cracking susceptibility of the sucker rod is not necessarily related to the tensile strength of the sucker rod. The 4330 sucker rod is not suitable for applications in wells with a high concentration of Cl−, but it is suitable for operation in alkaline conditions where corrosive media such as HCO3− and Cl− coexist. Under highly corrosive and highly mineralized conditions, the 30CrMoA sucker rod is less susceptible to stress corrosion. The stress corrosion cracking susceptibility of the 20CrMoA sucker rod is lower than that of the 4142 sucker rod. In high-salinity well fluids, the higher the use strength, the higher the stress corrosion cracking susceptibility of the high-strength sucker rod is. The test results for the weight-loss-based corrosion rate and plastic loss may contradict the determination of the corrosion susceptibility of the material under working conditions.