Qiaoqiao Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qiaoqiao Kang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jifang Tao
School of Information Science and Engineering, Shandong University, Qingdao 266237, China
3 shared publications - Yuzhe Lin
College of Electronics and Information, Qingdao University, Qingdao, China
2 shared publications Baoqi Wang
1 shared publicationChenglin Pua
1 shared publicationHaoxian Yan
1 shared publication- Jia Zhao
State Key Laboratory of Chips and Systems for Advanced Light Field Display, School of Shandong University-Hisense Optoelectronic Research Institute, Qingdao 266237, China
1 shared publication
Latest Publications
- 1 April 2026
- Published by Tsinghua University Press in Nano Research
- Vol. 19 (11)
Thermal cycle impact on polycrystalline silicon: Direct observation of mechanical properties and interfacial nanocrystalline grain defects
In the field of integrated circuits, polycrystalline silicon (poly-Si) is widely used in the preparation and packaging of semiconductor devices, featuring excellent electron mobility and stability. With the development of three-dimensional (3D) and heterogeneous integration in the semiconductor field, the role of poly-Si has changed, and its mechanical properties have become crucial. Tracing nanocrystalline grain defects (NCGD) formation strained and deformation in thermal remains a challenging issue for poly-Si stable and reliable application in engineering. Here, by tracking the NCGD behavior of multilayer poly-Si with silicon dioxide (SiO2) passivating during the manufacturing process of the technology, we explored the changes in the microstructure of the material when the strain deformation occurred, and concluded that the accumulation of thermal stress intensified the evolution of coherent twins (CTs) to incoherent twins (ICTs), and promoting the intensification of the strain behavior of the film layer. It is a pioneering work to explore poly-Si NCGD performance in the thermal fabrication. We obtain the thermal expansion deformation of poly-Si film and demonstrate it with the thermal cycle finite element model (TC-FEM). Then, we revealed the key factor to release compressive stress, in which the grain refinement (GR), grain size (GS), and grain boundary (GB) increasing induced CTs to ICTs. ICTs pose different obstacles to diffusion and dislocation movement and alter the rate and path of stress relaxation at high thermal conditions. Ultimately, this research enrich our understanding of NCGD in poly-Si materials. Our work highlights the complex interplay of polycrystalline structure, intra-and inter layer thermal exchange, as well as strained and deformation of poly-Si film. The findings of this work can have significant implications for the stability and reliability of 3D Not AND (NAND) flash memory and advanced semiconductor processing technology.
- 1 April 2026
- Published by Tsinghua University Press in Nano Research
- Vol. 19 (11)
Thermal cycle impact on polycrystalline silicon: Direct observation of mechanical properties and interfacial nanocrystalline grain defects
In the field of integrated circuits, polycrystalline silicon (poly-Si) is widely used in the preparation and packaging of semiconductor devices, featuring excellent electron mobility and stability. With the development of three-dimensional (3D) and heterogeneous integration in the semiconductor field, the role of poly-Si has changed, and its mechanical properties have become crucial. Tracing nanocrystalline grain defects (NCGD) formation strained and deformation in thermal remains a challenging issue for poly-Si stable and reliable application in engineering. Here, by tracking the NCGD behavior of multilayer poly-Si with silicon dioxide (SiO2) passivating during the manufacturing process of the technology, we explored the changes in the microstructure of the material when the strain deformation occurred, and concluded that the accumulation of thermal stress intensified the evolution of coherent twins (CTs) to incoherent twins (ICTs), and promoting the intensification of the strain behavior of the film layer. It is a pioneering work to explore poly-Si NCGD performance in the thermal fabrication. We obtain the thermal expansion deformation of poly-Si film and demonstrate it with the thermal cycle finite element model (TC-FEM). Then, we revealed the key factor to release compressive stress, in which the grain refinement (GR), grain size (GS), and grain boundary (GB) increasing induced CTs to ICTs. ICTs pose different obstacles to diffusion and dislocation movement and alter the rate and path of stress relaxation at high thermal conditions. Ultimately, this research enrich our understanding of NCGD in poly-Si materials. Our work highlights the complex interplay of polycrystalline structure, intra-and inter layer thermal exchange, as well as strained and deformation of poly-Si film. The findings of this work can have significant implications for the stability and reliability of 3D Not AND (NAND) flash memory and advanced semiconductor processing technology.
- Open Access
A Reliability Analysis of a MEMS Flow Sensor with an Accelerated Degradation Test
With the wide application of flow sensors, their reliability under extreme conditions has become a concern in recent years. The reliability of a Micro Electro Mechanical Systems (MEMS) flow sensor under temperature is researched in this paper. This flow sensor consists of two parts, a sensor chip and a signal-processing system (SPS). Firstly, the step-stress accelerated degradation test (SSADT) is implemented. The sensor chip and the flow sensor system are tested. The results show that the biggest drift is 3.15% for sensor chips under 150 °C testing conditions, while 32.91% is recorded for the flowmeters. So, the attenuation of the SPS is significant to the degeneration of this flowmeter. The minimum drift of the SPS accounts for 82.01% of this flowmeter. Secondly, using the Coffin–Manson model, the relationship between the cycle index and is established. The lifetime with a different is estimated using the Arrhenius model. In addition, Weibull distribution (WD) is applied to evaluate the lifetime distribution. Finally, the reliability function of the WD is demonstrated, and the survival rate within one year is 87.69% under 85 °C conditions. With the application of accelerated degradation testing (ADT), the acquired results are innovative and original. This research illustrates the reliability research, which provides a relational database for the application of this flow sensor.Open AccessA Reliability Analysis of a MEMS Flow Sensor with an Accelerated Degradation Test
With the wide application of flow sensors, their reliability under extreme conditions has become a concern in recent years. The reliability of a Micro Electro Mechanical Systems (MEMS) flow sensor under temperature is researched in this paper. This flow sensor consists of two parts, a sensor chip and a signal-processing system (SPS). Firstly, the step-stress accelerated degradation test (SSADT) is implemented. The sensor chip and the flow sensor system are tested. The results show that the biggest drift is 3.15% for sensor chips under 150 °C testing conditions, while 32.91% is recorded for the flowmeters. So, the attenuation of the SPS is significant to the degeneration of this flowmeter. The minimum drift of the SPS accounts for 82.01% of this flowmeter. Secondly, using the Coffin–Manson model, the relationship between the cycle index and is established. The lifetime with a different is estimated using the Arrhenius model. In addition, Weibull distribution (WD) is applied to evaluate the lifetime distribution. Finally, the reliability function of the WD is demonstrated, and the survival rate within one year is 87.69% under 85 °C conditions. With the application of accelerated degradation testing (ADT), the acquired results are innovative and original. This research illustrates the reliability research, which provides a relational database for the application of this flow sensor. - Open Access
- 19 September 2023
- Published by MDPI AG in Preprints.org
Reliability Analysis of A MEMS Flow Sensor with Accelerated Degradation Test
With the wide application of flow sensor, their reliability under extreme conditions has been concerned in recent years. The reliability of a Micro Electro Mechanical Systems flow sensor under temperature (Ts) is researched in this paper. Firstly, the Step-stress accelerated degradation test is designed. Because this flow sensor consists flow sensor chip and signal processing system, the accelerated degradation testing is implemented, respectively. While the results show that the biggest drift is 3.15% for flow sensor chips with 150℃ conditions, and 32.91% for this flowmeter. By analysis, it could be found that the attenuation of the signal processing system is significant to the degeneration of this flowmeter. The minimum drift of the signal processing system accounts for 82.01% of this flowmeter. Secondly, using the Coffin-Manson model, the relationship between cycle-index and Ts is established. And the lifetime with different Ts is estimated by the Arrhenius model. In addition, the Weibull distribution is applied to evaluate the lifetime distribution. Finally, the reliability function of the Weibull distribution is demonstrated, and the survival rate within one year is 87.69% with 85℃ conditions. Thus, by the application of accelerated degradation testing, the acquired results are innovative and original. This research illustrates the reliability research, which provides a relational database for the application of this flow sensor.
- 19 September 2023
- Published by MDPI AG in Preprints.org
Open AccessReliability Analysis of A MEMS Flow Sensor with Accelerated Degradation Test
With the wide application of flow sensor, their reliability under extreme conditions has been concerned in recent years. The reliability of a Micro Electro Mechanical Systems flow sensor under temperature (Ts) is researched in this paper. Firstly, the Step-stress accelerated degradation test is designed. Because this flow sensor consists flow sensor chip and signal processing system, the accelerated degradation testing is implemented, respectively. While the results show that the biggest drift is 3.15% for flow sensor chips with 150℃ conditions, and 32.91% for this flowmeter. By analysis, it could be found that the attenuation of the signal processing system is significant to the degeneration of this flowmeter. The minimum drift of the signal processing system accounts for 82.01% of this flowmeter. Secondly, using the Coffin-Manson model, the relationship between cycle-index and Ts is established. And the lifetime with different Ts is estimated by the Arrhenius model. In addition, the Weibull distribution is applied to evaluate the lifetime distribution. Finally, the reliability function of the Weibull distribution is demonstrated, and the survival rate within one year is 87.69% with 85℃ conditions. Thus, by the application of accelerated degradation testing, the acquired results are innovative and original. This research illustrates the reliability research, which provides a relational database for the application of this flow sensor.
- 17 June 2023
- Published by Elsevier in Microelectronics Reliability
- Vol. 147, 115026
Reliability estimation of thin film platinum resistance MEMS thermal mass flowmeter by step-stress accelerated life testing
- 17 June 2023
- Published by Elsevier in Microelectronics Reliability
- Vol. 147, 115026
Reliability estimation of thin film platinum resistance MEMS thermal mass flowmeter by step-stress accelerated life testing