YLYuzhe Lin

Yuzhe Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuzhe Lin has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hybrid Modeling and Experimental Validation for Gas Factor Determination in a MEMS Thermal Flow Meter

    by Wei Tian, Hanzhe Liu, Maosen Xu, Jinghua Lin, Zongkun Wang, Yuzhe Lin, Jifang Tao

    Undetermined gas factors of micro-electro-mechanical systems (MEMS) thermal mass flow meters (MFMs) constitute a critical bottleneck limiting their industrial adoption, particularly in semiconductor manufacturing. This limitation stems from current manufacturing practices, where only N2-calibrated products are mass-produced, whereas real-world applications require gas factor switching for multigas measurement. To address this challenge, this work presents a porous silicon-based MEMS thermal MFM and proposes a corresponding gas factor determination method using a hybrid modeling-experimental approach. The implementation involves: derivation of mathematical correlations among the output signal, gas flow rate, and thermophysical parameters via constitutive modeling, followed by empirical correction of model exponents using experimental datasets. The gas factors derived from this relationship were empirically validated using six test gases under constant ambient conditions. The results demonstrate high effectiveness, with all observed absolute errors confined within 6.4%FS, and exhibit excellent consistency. This work provides a practical methodology for gas factor determination in MEMS thermal MFMs, addressing a major limitation that restricts their universality in multigas measurement.

  • NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C

    by Wei Tian, Yuhan Liu, Jiale Kang, Zhitao Liao, Yuzhe Lin, Jifang Tao

    This letter presents a corrosion-resistant MEMS calorimetric flow sensor that addresses reliability challenges in ammonia (NH3) flow measurement. The employment of Parylene C anti-corrosion coating extends the sensor’s stability in 25 wt% ammonia solution to over 168 hours, demonstrating enhanced resistance to alkaline corrosion. Additionally, compared with suspended membrane designs, the adoption of porous silicon thermal isolation structure reduces the zero-flow voltage difference when measuring NH3 versus N2 from 2.02%FS to 0.07%FS, enabling mass production using an N2-calibration scheme. The experimental results demonstrate the sensor’s potential for replacing capillary-based flow sensors in semiconductor manufacturing.


  • Development of a MEMS Thermal Flow Sensor With High Reliability and Universality for Various Gases

    by Wei Tian, Yuzhe Lin, Lianggong Wen, Maosen Xu, Jinghua Lin, Guoqing Hu, Jifang Tao

    This paper presents an improved calorimetric MEMS flow sensor to meet the needs of large-scale industrial applications such as semiconductor and photovoltaics. Reliability and universality are considered the most critical factors for these fields, for which the porous silicon-based sensor was designed, fabricated and tested rigorously with eight gases. The results demonstrated that the sensor maintained nearly identical zero-flow outputs across various static gas environments (using N2 as the baseline, with deviations ranging from 0.01%FS for CO to 0.69%FS for He). Moreover, well-defined conversion coefficients were established between any two gases. This characteristic enables the practical application of N2-calibrated sensors to other gases through coefficient conversion, achieving an accuracy error within 2.0%FS. In addition, the sensor can survive and maintain its sensing capabilities even during continuous SiH4 combustion reactions and under heavy pollution, whereas the suspended membrane-based sensor ruptures. This innovative work makes MEMS flow sensors more convenient and reliable in complex industrial applications, potentially replacing traditional flow sensors based on capillary structures.[2025-0009]


  • Open Access

    A MEMS Pirani Vacuum Gauge Based on Porous Silicon

    by Yuzhe Lin, Zichao Zhang, Jifang Tao, Lianggong Wen

    Vacuum gauges based on Micro-Electro-Mechanical System (MEMS) technology have the advantages of small size, high reliability, and low cost, so they are widely used in semiconductor, chemical, laboratory, and aerospace. In this paper, a high-reliability MEMS Pirani vacuum gauge based on a porous silicon platform is designed, fabricated, and characterized. The repeatability within 4~105 Pa has been tested. The porous silicon acting as a support material achieved a porosity of 68% and a thermal conductivity of 3.5 W/(m·K), and the surface morphology of the porous silicon is smooth. The proposed MEMS Pirani vacuum gauge containing no suspended thin-film structures has good mechanical stability and is unaffected by mechanical shock and vibration in operation.


  • A High-Accuracy Ultrasonic Gas Flowmeter Based on Scandium-Doped Aluminum Nitride Piezoelectric Micromachined Ultrasonic Transducers

    by Hanzhe Liu, Xiangyang Wang, Chongbin Liu, Yuzhe Lin, Lujiang Zhang, Hui Zhao, Xiaofei Cui, Jianke Feng, Guoqiang Wu, Jifang Tao

    This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.


  • Open Access

    Development of a Compact NDIR CO2 Gas Sensor for a Portable Gas Analyzer

    by Maosen Xu, Wei Tian, Yuzhe Lin, Yan Xu, Jifang Tao

    A carbon dioxide (CO2) gas sensor based on non-dispersive infrared (NDIR) technology has been developed and is suitable for use in portable devices for high-precision CO2 detection. The NDIR gas sensor comprises a MEMS infrared emitter, a MEMS thermopile detector with an integrated optical filter, and a compact gas cell with high optical coupling efficiency. A dual-ellipsoid mirror optical system was designed, and based on optical simulation analysis, the structure of the dual-ellipsoid reflective gas chamber was designed and optimized, achieving a coupling efficiency of up to 54%. Optical and thermal simulations were conducted to design the sensor structure, considering thermal management and light analysis. By optimizing the gas cell structure and conditioning circuit, we effectively reduced the sensor’s baseline noise, enhancing the overall reliability and stability of the system. The sensor’s dimensions were 20 mm × 10 mm × 4 mm (L × W × H), only 15% of the size of traditional NDIR gas sensors with equivalent detection resolution. The developed sensor offers high sensitivity and low noise, with a sensitivity of 15 μV/ppm, a detection limit of 90 ppm, and a resolution of 30 ppm. The total power consumption of the whole sensor system is 6.5 mW, with a maximum power consumption of only 90 mW.


  • Open Access

    Design and Performance Evaluation of a Deep Ultraviolet LED-Based Ozone Sensor for Semiconductor Industry Applications

    by Maosen Xu, Xin Tian, Yuzhe Lin, Yan Xu, Jifang Tao

    Ozone (O3) is a critical gas in various industrial applications, particularly in semiconductor manufacturing, where it is used for wafer cleaning and oxidation processes. Accurate and reliable detection of ozone concentration is essential for process control, ensuring product quality, and safeguarding workplace safety. By studying the UV absorption characteristics of O3 and combining the specific operational needs of semiconductor process gas analysis, a pressure-insensitive ozone gas sensor has been developed. In its optical structure, a straight-through design without corners was adopted, achieving a coupling efficiency of 52% in the gas chamber. This device can operate reliably in a temperature range from 0 °C to 50 °C, with only ±0.3% full-scale error across the entire temperature range. The sensor consists of a deep ultraviolet light-emitting diode in a narrow spectrum centered at 254 nm, a photodetector, and a gas chamber, with dimensions of 85 mm × 25 mm × 35 mm. The performance of the sensor has been meticulously evaluated through simulation and experimental analysis. The sensor’s gas detection accuracy is 750 ppb, with a rapid response time (t90) of 7 s, and a limit of detection of 2.26 ppm. It has the potential to be applied in various fields for ozone monitoring, including the semiconductor industry, water treatment facilities, and environmental research.


  • Open Access

    Design and Simulation of an Ultra-Low-Power Hydrogen Sulfide Gas Sensor with a Cantilever Structure

    by Xin Tian, Jifang Tao, Maosen Xu, Yuzhe Lin, Jia Zhao

    Metal oxide gas sensors usually require a few tens of milliwatts of power consumption to operate at high temperature, which limits their application in mobile and portable devices. Here, we proposed a cantilever structure to build an ultra-low power gas sensor for hydrogen sulfide gas detection. By employing a nano-film size effect to reduce the thermal conductivity of the material, and self-heated corrugation configuration, the power consumption of the gas sensor is significantly reduced. Through numerical analysis and finite element simulation, two different gas sensors were designed and the power consumption and stress distribution were analyzed and optimized. Under the operating temperature of 200 °C, only 0.27 mW power is consumed, the stress value is less than 250 MPa and the displacement is a few hundred of nanometers. The results serve as a guide and reference for ultra-low power MEMS device designs.


  • Open Access

    A Reliability Analysis of a MEMS Flow Sensor with an Accelerated Degradation Test

    by Qiaoqiao Kang, Yuzhe Lin, Jifang Tao

    With the wide application of flow sensors, their reliability under extreme conditions has become a concern in recent years. The reliability of a Micro Electro Mechanical Systems (MEMS) flow sensor under temperature (Ts) is researched in this paper. This flow sensor consists of two parts, a sensor chip and a signal-processing system (SPS). Firstly, the step-stress accelerated degradation test (SSADT) is implemented. The sensor chip and the flow sensor system are tested. The results show that the biggest drift is 3.15% for sensor chips under 150 °C testing conditions, while 32.91% is recorded for the flowmeters. So, the attenuation of the SPS is significant to the degeneration of this flowmeter. The minimum drift of the SPS accounts for 82.01% of this flowmeter. Secondly, using the Coffin–Manson model, the relationship between the cycle index and Ts is established. The lifetime with a different Ts is estimated using the Arrhenius model. In addition, Weibull distribution (WD) is applied to evaluate the lifetime distribution. Finally, the reliability function of the WD is demonstrated, and the survival rate within one year is 87.69% under 85 °C conditions. With the application of accelerated degradation testing (ADT), the acquired results are innovative and original. This research illustrates the reliability research, which provides a relational database for the application of this flow sensor.