RQRui Qiu

Rui Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rui Qiu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computational Chemistry‐Driven Advances in Eco‐Friendly Insulation Gas Research: Multi‐Dimensional Prediction, Synergistic Screening, Stability Evaluation and Molecular Design

    by Rui Qiu, Wenjun Zhou, Xuzhu Dong, Keli Gao, Baoshan Wang, Pascal Brault, Han Li, Yu Zheng, Shubo Ren

    Sulphur hexafluoride has become a priority substance for greenhouse gas mitigation in electric systems. An ideal substitute should simultaneously satisfy requirements for dielectric strength, boiling point, global warming potential and chemical stability; however, these metrics are deeply coupled and mutually constraining at the molecular level. Computational chemistry, encompassing quantum‐chemical calculations and molecular dynamics simulations, is transforming this field from empirical trial and error into a computationally guided design paradigm. This review organises the theoretical methods and key advances of multi‐tiered performance prediction, synergistic screening, stability evaluation and molecular design. Multi‐level prediction frameworks for core performance are converging into integrated synergistic computation, while screening combined with Pareto multi‐objective optimisation has enabled a multi‐dimensional global optimisation. Stability assessments have elucidated the mechanisms of self‐decomposition and interfacial reactions. Molecular design has progressed from functional‐group hybridisation and H/F substitution at the single‐molecule level to synergistic component optimisation in gas mixtures. Computational chemistry has demonstrated the capacity to accelerate full‐chain engineering translation, compressing the cycle from molecular discovery to prototype validation. Looking forward, the progressive integration of artificial intelligence technologies is poised to propel this field towards a new paradigm defined by the synergy of computational prediction and intelligent empowerment.

  • Open Access

    Angular dependence in ultraviolet imaging of HVDC partial discharges: Mechanism investigation and correction approach

    by Jinwei Lv, Hui Li, Wei Ma, Dezhen Zhang, Xiuhai Wu, Rui Zhu, Rui Qiu

    To address the observation angle effects on the diagnosis accuracy of ultraviolet (UV) imaging for partial discharge (PD) monitoring in high-voltage direct current (HVDC) equipment, this study investigates the underlying mechanism and develops a corresponding correction method. A dual-channel, angularly adjustable synchronous UV imaging platform was established to acquire synchronized datasets under various viewing angles, including both photon counting and UV spot data. A probabilistic statistical analysis of the UV spots was performed to characterize their spatiotemporal distribution, resulting in the UV spot distribution maps. The results indicate a sinusoidal relationship between the viewing angle difference and the photon counting ratio from the two channels, with a peak occurring near 45°. This angular dependence is attributed to changes in the cross section and the spatial overlap of the discharge regions in the UV spot distribution maps. A regression model based on the sine function was established to correct the photon counting results for variations in observation angle. The mechanism behind the angle-dependent photon counting variation in UV detection is elucidated, thereby providing a foundation for improving the accuracy and reliability of UV-based PD diagnostics in HVDC equipment.


  • Open Access

    Nonlinear photon emission and discharge mode transitions in HVDC needle–needle electrodes: Insights from UV photon spot distribution mapping

    by Zhiliang Yin, Wei Ma, Xiuhai Wu, Jinwei Lv, Xiang Shen, Rui Qiu

    This study proposes a methodology for the development of ultraviolet (UV) spot distribution mapping with probabilistic processing, with the objective of addressing the challenges associated with the monitoring of partial discharge (PD) in high-voltage direct current (HVDC) equipment and analyzing its mechanism. An experimental platform with adjustable needle–needle electrodes (5–25 mm gap) was established to simulate insulation defects, enabling quantitative analysis through a dedicated UV image processing framework. The research demonstrates that the transition of photon counting characteristics from bell-shaped to U-shaped distributions with increasing electrode distance is governed by the spatial reorganization of discharge regions. UV spot distribution mapping reveals that this nonlinear behavior stems from expanded UV emission zones at larger distances and constrained discharge region coalescence at smaller gaps, while spectral red-shift toward infrared wavelengths during discharge intensification further modulates photon counting patterns. A unified mathematical model was developed, incorporating both spatial and spectral evolution mechanisms. The unified model, designated as, has been shown to be effective in this regard. Spatial analysis identified characteristic discharge core zones with pronounced polarity asymmetry. The probabilistic methodology effectively discriminates between persistent discharge zones and random photon events, enabling quantitative assessment of discharge stability and evolution. The findings establish a framework correlating UV spot distribution dynamics with photon counting behavior, providing both fundamental insights into DC PD mechanisms and practical methodologies for insulation condition assessment in HVDC systems.

  • Open Access

    Ultraviolet-spot distribution and photon-count variation characteristics in direct current partial discharge

    by Xiuhai Wu, Fuquan Yi, Wei Ma, Yuedong Hao, Jin Cheng, Jinwei Lv, Rui Qiu

    To address the challenges of ultraviolet (UV) imaging technology for partial discharge (PD) in high-voltage direct current (HVDC) converter stations (equipment), a comprehensive UV image processing methodology has been developed, and a needle–needle electrode experimental platform has been established. The dynamic characteristics of UV photon counts and spatial distribution patterns of UV spots during PD processes were systematically investigated. Our research reveals that there is an inverted U-shaped distribution between UV photon counts and applied voltage. This demonstrates how discharge mechanisms evolve from molecular excitation to atomic ionization. Furthermore, probability distribution analysis identified distinctive spatial features of DC PD and elucidated the correlation between discharge modes and spatial distribution patterns. Based on these findings, a hierarchical monitoring strategy is proposed, which could optimize integration time and probability thresholds synergistically, enabling complete process monitoring from corona inception detection through discharge development tracking to precise source localization. This research provides fundamental insights and practical methodologies for UV-based monitoring and diagnostics of PD in HVDC converter stations (equipment).

  • Top Cited Papers
    Open Access

    A review of advanced acoustic‐chemical‐optical partial discharge monitoring techniques for ultra‐high‐voltage gas‐insulated equipment

    by Xianhao Fan, Weiqi Qin, Rui Qiu, Yiming Zang, Wu Lu, Yin Zhang, Ruiying Chen, Fangwei Liang, Guangyu Sun, Hanhua Luo, et al.

    Partial discharge (PD) detection is considered one of the most crucial and effective methods for identifying defects in electrical equipment. Consequently, investigating advanced and efficient PD monitoring techniques is essential for the development of gas‐insulated equipment (GIE) and the construction of ultra‐high‐voltage (UHV) networks. This paper first explores the causes and impact characteristics of various defects in GIE based on experimental results and simulation analysis. It then reviews current research on advanced PD measurement techniques, integrating acoustic, chemical and optical methods. The findings preliminarily demonstrate the unique advantages and applicability of the advanced methods for complex detection environments. Finally, this paper addresses the technical challenges and potential breakthroughs associated with these detection techniques. In this regard, this study aims to provide technical insights and research directions for defect detection techniques in UHV GIE.


  • Feasibility Study of Using C4F7N/Helium in Eco-Friendly Gas-Insulated Transformer: Dielectric Strength and Heat Dissipation Performance

    by Han Yang, Han Li, Chengwu Jin, Shizhuo Hu, Shubo Ren, Yu Zheng, Rui Qiu

    This contribution proposes an eco-friendly insulation gas mixture of perfluoroisobutyronitrile (C4F7N)/helium with good heat transfer performance for gas-insulated transformers (GITs). The dielectric strength of C4F7N/helium was assessed by AC breakdown test and voltage withstand test. The heat dissipation performance of the mixture was evaluated by test of temperature rise due to short-circuit on a self-cooling GIT. The test results demonstrated that the dielectric strength of C4F7N/helium exhibited a synergistic effect in various proportions. Especially for 40% C4F7N /60% helium, its dielectric strength could exceed that of SF6 used in existing GITs. After filling it into the eco-friendly GIT, the dielectric strength remains stable and the average temperature rise of the winding could be reduced by over 20% . In addition, based on the convection heat dissipation model, a calculation method for the average temperature rise of the eco-friendly GIT was adjusted. The errors of the model were found to be within a margin of ±3°C for C4F7N/helium under different pressures and proportions. The dielectric strength and heat dissipation performance of the mixture indicated that 40% C4F7N /60% helium could directly replace SF6 without adjusting voltage levels or insulation gaps in larger capacity and eco-friendly GITs.


  • A Method to Localize the Axial Position of Partial Discharges in GIL by Gas Sensors

    by Rui Qiu, Wenjun Zhou, Pascal Brault, Yu Zheng, Gen Li, Han Yang, Han Li

    This article proposes a novel method to realize the partial discharge (PD) localizing function of gas sensors in gas-insulated transmission lines (GIL). First, the diffusion characteristics of decomposition products were studied. The Fuller-Schettler-Giddings (FSG) model was corrected to obtain decomposition products diffusion coefficients in high-pressure SF6. The finite element method (FEM) calculated the temperature rise, convection, and diffusion of decomposition products in GIL. With the relationship between the concentration variation and positions, a PD defects location method was proposed. The results indicate that the decomposition products would diffuse rapidly in the radial direction with the convection. Gas diffusion at the top of the GIL was faster than that at the bottom. Hence, the gas sensors were suggested to be set at the top of GIL. The axial diffusion was much slower and mainly affected by the temperature and diffusion coefficient. For a long GIL unit, the diffusion of decomposition products could be simplified to 1-D. In diffusion, the delay of the product concentration is negatively correlated with the square of the distance. That quantitative relationship could be used for localizing PD by the concentration increase delay detected by the sensors on both sides of the defect. The localization error would decrease with the increase of diffusion coefficient (rate) and prolonged monitoring (diffusion) time. The accuracy of the localization would also increase when the defect is close to the midpoint of the sensors.


  • Dielectric Properties and Synergistic Effect Evaluation Method of C4F7N Mixtures

    by Shizhuo Hu, Rui Qiu, Wenjun Zhou

    In order to accelerate the screening and design of new eco-friendly insulating mixtures, AC breakdown tests were performed on 9 binary C 4 F 7 N mixtures, specifically C 4 F 7 N mixed with rare gases (He, Ne, Ar), conventional gases (CO 2 , N 2 ), and fluorocarbon gases (CF 4 , C 2 F 6 , C 3 F 6 , and C 3 F 8 ), under slightly non-uniform electric fields. The effects of pressure, buffer gas, and mixing ratio on the AC breakdown characteristics were analyzed. It is found that the AC breakdown voltages of the 9 C 4 F 7 N mixtures increase linearly with increasing pressure. As the mixing ratio of C 4 F 7 N increases, the impact of the buffer gas on the AC breakdown voltages decreases. All C 4 F 7 N mixtures show synergistic effects with segmented characteristics that transition from nonlinear to linear. And the synergistic effect of C 4 F 7 N/CO 2 mixture is the most significant. A new method for evaluating the degree of synergistic effects is proposed. Based on the synergistic effect evaluation coefficient N and the dielectric strength of gas components, the dielectric strengths of binary mixtures can be calculated and predicted.


  • Open Access

    Methods for alleviation of impacts of axial diffusion on decomposition products monitoring in gas‐insulated transmission lines

    by Rui Qiu, Weijiang Chen, Wenjun Zhou, Ming Liu, Jianming Zou, Yu Zheng, Han Li, Shizhuo Hu, Jianhui Yu

    Considering the long length of gas‐insulated transmission lines (GILs), novel methods are required to alleviate the impacts of axial diffusion on decomposition products' monitoring. The diffusion process of two typical decomposition products, SO 2 and SO 2 F 2 , was studied. During the diffusion experiments, SO 2 and SO 2 F 2 were generated by partial discharges. Based on Fick’s law, an axial diffusion model of SO 2 and SO 2 F 2 was proposed. By combining the experiment and simulation results, it was found that the diffusion coefficient of SO 2 was greater than that of SO 2 F 2 . In addition, the concentration variation at different positions would experience some delay and decay in axial direction. The delay and decay were inversely related to the diffusion coefficient and increased with prolongation of the distance. Based on the diffusion characteristics determined, methods for optimising the monitoring positions, correcting concentration, and using the concentration ratio and generation rate were proposed to alleviate the impacts of diffusion. The methods could allow the decomposition products to be monitored in 1 month and reduce the monitoring error to 10% or less. The diffusion model and the methods could be useful for monitoring decomposition products in GILs.