Aseel Mohammed Al-Khafaji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aseel Mohammed Al-Khafaji has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mohammed Hussein M. Alsharbaty
Department of Prosthodontics, College of Dentistry, University of Al-Ameed, Karbala 56001, Iraq
2 shared publications - Ali Mohammad Ali Aljafery
Department of Prosthodontic, College of Dentistry, University of Kufa, Najaf 54001, Iraq
1 shared publication - Aseel Mohammed Al-Khafaji
Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
1 shared publication - Ashraf Shubbar
Private Dental Practice, 5000 Odense, Denmark
1 shared publication - Hasan Ali Alsailawi
Department of Basic Sciences, College of Dentistry, University of Karbala, Karbala 56001, Iraq
1 shared publication - Hasanen Ali AlNamel
Department of Prosthodontics, College of Dentistry, University of Basrah, Basrah 61001, Iraq
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 731
Influence of Aluminosilicate Clay Nanofiller Reinforcement on the Flexural Strength, Surface Hardness, Surface Roughness and Microstructure of Auto-Polymerized PMMA Denture Base Resin: An In Vitro Study
Background/Objectives: Auto-polymerized polymethyl methacrylate (PMMA) is widely used in denture repair, relining, and base-plate fabrication but is susceptible to fracture due to limited flexural strength and fatigue resistance. This in vitro study investigated the concentration-dependent effects of synthetic aluminosilicate clay (ASC) nanoparticles on the flexural strength, Vickers hardness, surface roughness, and microstructure of auto-polymerized PMMA. Methods: A total of 120 specimens of SR Triplex Cold were prepared with 0 (control), 1, 3, or 5 wt.% ASC (50–100 nm; n = 30/group). ASC was dispersed in the monomer by probe sonication for 10 min. After pressure curing and storage in distilled water at 37 °C for 7 days, flexural strength, Vickers hardness, and surface roughness (Ra) were measured (n = 10/test/group). Microstructural characterization employed SEM, EDX, and XRD. Data were analyzed using ANOVA with appropriate post hoc tests (α = 0.05). Results: ASC concentration significantly affected all three properties (p < 0.001). At 1 wt.% ASC, flexural strength increased from 61.50 ± 3.37 to 79.70 ± 2.11 MPa (+29.6%), and hardness increased from 84.39 ± 3.81 to 97.84 ± 2.56 VHN. At 3 and 5 wt.%, these properties declined to 52.60 ± 3.75 and 31.70 ± 2.83 MPa, and to 63.97 ± 2.94 and 27.73 ± 2.62 VHN, respectively. Surface roughness increased with ASC concentration, from 0.102 ± 0.012 µm (control) to 0.195 ± 0.013, 0.245 ± 0.022, and 0.327 ± 0.035 µm at 1, 3, and 5 wt.%, respectively. SEM revealed favorable particle dispersion, crack deflection, and particle bridging at 1 wt.%, whereas higher concentrations promoted agglomeration, microvoid formation, and interfacial debonding. XRD confirmed the coexistence of the amorphous PMMA phase and crystalline aluminosilicate reflections. Conclusions: Under the conditions tested, 1 wt.% ASC provided the most favorable balance of mechanical and surface properties, improving flexural strength and hardness while maintaining Ra below 0.2 µm. Higher concentrations compromised mechanical performance, with the 3 and 5 wt.% groups falling below the minimum flexural strength for Type 2 polymers. The findings suggest that reinforcement depends primarily on particle dispersion and interfacial stress transfer rather than chemical modification of the PMMA backbone.
- 9 November 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 731
Open AccessInfluence of Aluminosilicate Clay Nanofiller Reinforcement on the Flexural Strength, Surface Hardness, Surface Roughness and Microstructure of Auto-Polymerized PMMA Denture Base Resin: An In Vitro Study
Background/Objectives: Auto-polymerized polymethyl methacrylate (PMMA) is widely used in denture repair, relining, and base-plate fabrication but is susceptible to fracture due to limited flexural strength and fatigue resistance. This in vitro study investigated the concentration-dependent effects of synthetic aluminosilicate clay (ASC) nanoparticles on the flexural strength, Vickers hardness, surface roughness, and microstructure of auto-polymerized PMMA. Methods: A total of 120 specimens of SR Triplex Cold were prepared with 0 (control), 1, 3, or 5 wt.% ASC (50–100 nm; n = 30/group). ASC was dispersed in the monomer by probe sonication for 10 min. After pressure curing and storage in distilled water at 37 °C for 7 days, flexural strength, Vickers hardness, and surface roughness (Ra) were measured (n = 10/test/group). Microstructural characterization employed SEM, EDX, and XRD. Data were analyzed using ANOVA with appropriate post hoc tests (α = 0.05). Results: ASC concentration significantly affected all three properties (p < 0.001). At 1 wt.% ASC, flexural strength increased from 61.50 ± 3.37 to 79.70 ± 2.11 MPa (+29.6%), and hardness increased from 84.39 ± 3.81 to 97.84 ± 2.56 VHN. At 3 and 5 wt.%, these properties declined to 52.60 ± 3.75 and 31.70 ± 2.83 MPa, and to 63.97 ± 2.94 and 27.73 ± 2.62 VHN, respectively. Surface roughness increased with ASC concentration, from 0.102 ± 0.012 µm (control) to 0.195 ± 0.013, 0.245 ± 0.022, and 0.327 ± 0.035 µm at 1, 3, and 5 wt.%, respectively. SEM revealed favorable particle dispersion, crack deflection, and particle bridging at 1 wt.%, whereas higher concentrations promoted agglomeration, microvoid formation, and interfacial debonding. XRD confirmed the coexistence of the amorphous PMMA phase and crystalline aluminosilicate reflections. Conclusions: Under the conditions tested, 1 wt.% ASC provided the most favorable balance of mechanical and surface properties, improving flexural strength and hardness while maintaining Ra below 0.2 µm. Higher concentrations compromised mechanical performance, with the 3 and 5 wt.% groups falling below the minimum flexural strength for Type 2 polymers. The findings suggest that reinforcement depends primarily on particle dispersion and interfacial stress transfer rather than chemical modification of the PMMA backbone.
- Open Access
- 30 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 559
Nano-Biomaterial-Based Dental Composites: Bridging the Laboratory-to-Clinic Translation Gap—A Comprehensive Review
The modern field of restorative dentistry uses multifunctional nano-filler particles made from different substances such as metal nanoparticles (silver and zinc oxides), nano-silica, dendrimers, and carbon nano-structures. Numerous laboratory investigations demonstrate that these nano-biomaterials outperform traditional micro- and nano-hybrid composites in a variety of parameters, including flexural and compressive strength, wear resistance, antibacterial activity, and remineralization potential. Even with these advances, there is a wide gap between laboratory success and routine clinical application. We present a narrative review, collating evidence on nano-biomaterial dental composites and key barriers to in vivo translation across the material, biological, manufacturing, regulatory pathway, and long-term function domains involved at all lifecycle stages of innovation discourse and propose solutions toward accelerating clinical uptake. This methodology was based on a descriptive-analytical review of the PubMed, ScienceDirect, Scopus, and Google Scholar literature from 2000 to 2026 (with special emphasis on studies conducted between 2019 and 2026), using the following keywords as descriptors: nanodentistry; dental nanocomposite; nanoparticle; biocompatibility; clinical translation targeting in vitro, in vivo, and clinical studies. Four common translation barriers were collectively recognized: nanoparticle agglomeration and interfacial bonding weaknesses in hydrophobic resin matrices; unresolved biocompatibility issues with cytotoxicity, oxidative stress, and the systemic migration of nanoparticles; elaborate or expensive-to-scale synthetic routes paired with the need for standardization across testing protocols as regulations defining “composite materials” evolve around some nano-fillers; lastly, a consistent disconnect between lab-based short-term results and long-term durability (clinical validity) under cyclic mechanical/chemical stress. Emerging promising strategies are highlighted, including nanoparticle surface functionalization, stimuli-responsive “smart” bioactive composites, self-healing systems, and 3D-printed nanocomposites. The review concludes that the gap between lab and clinic could be closed with simultaneous advances in materials engineering, biosafety testing, manufacturing at scale, and regulatory science. A four-phase, five-year roadmap (2025–2030) organized around material innovation, digital integration, clinical validation, and commercial adoption that provides a structured agenda for multidisciplinary collaboration is proposed to develop safer, more durable, and patient-centered restorative dentistry.
- 30 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (11) , 559
Open AccessNano-Biomaterial-Based Dental Composites: Bridging the Laboratory-to-Clinic Translation Gap—A Comprehensive Review
The modern field of restorative dentistry uses multifunctional nano-filler particles made from different substances such as metal nanoparticles (silver and zinc oxides), nano-silica, dendrimers, and carbon nano-structures. Numerous laboratory investigations demonstrate that these nano-biomaterials outperform traditional micro- and nano-hybrid composites in a variety of parameters, including flexural and compressive strength, wear resistance, antibacterial activity, and remineralization potential. Even with these advances, there is a wide gap between laboratory success and routine clinical application. We present a narrative review, collating evidence on nano-biomaterial dental composites and key barriers to in vivo translation across the material, biological, manufacturing, regulatory pathway, and long-term function domains involved at all lifecycle stages of innovation discourse and propose solutions toward accelerating clinical uptake. This methodology was based on a descriptive-analytical review of the PubMed, ScienceDirect, Scopus, and Google Scholar literature from 2000 to 2026 (with special emphasis on studies conducted between 2019 and 2026), using the following keywords as descriptors: nanodentistry; dental nanocomposite; nanoparticle; biocompatibility; clinical translation targeting in vitro, in vivo, and clinical studies. Four common translation barriers were collectively recognized: nanoparticle agglomeration and interfacial bonding weaknesses in hydrophobic resin matrices; unresolved biocompatibility issues with cytotoxicity, oxidative stress, and the systemic migration of nanoparticles; elaborate or expensive-to-scale synthetic routes paired with the need for standardization across testing protocols as regulations defining “composite materials” evolve around some nano-fillers; lastly, a consistent disconnect between lab-based short-term results and long-term durability (clinical validity) under cyclic mechanical/chemical stress. Emerging promising strategies are highlighted, including nanoparticle surface functionalization, stimuli-responsive “smart” bioactive composites, self-healing systems, and 3D-printed nanocomposites. The review concludes that the gap between lab and clinic could be closed with simultaneous advances in materials engineering, biosafety testing, manufacturing at scale, and regulatory science. A four-phase, five-year roadmap (2025–2030) organized around material innovation, digital integration, clinical validation, and commercial adoption that provides a structured agenda for multidisciplinary collaboration is proposed to develop safer, more durable, and patient-centered restorative dentistry.
- Open Access
- 8 April 2024
- Published by Wiley in BioMed Research International
- Vol. 2024, 1-11
Evaluation of High-Performance Polyether Ether Ketone Polymer Treated with Piranha Solution and Epigallocatechin-3-Gallate Coating
Background. Dental implantation has become a standard procedure with high success rates, relying on achieving osseointegration between the implant surface and surrounding bone tissue. Polyether ether ketone (PEEK) is a promising alternative to traditional dental implant materials like titanium, but its osseointegration capabilities are limited due to its hydrophobic nature and reduced surface roughness. Objective. The aim of the study is to increase the surface roughness and hydrophilicity of PEEK by treating the surface with piranha solution and then coating the surface with epigallocatechin-3-gallate (EGCG) by electrospraying technique. Materials and Methods. The study includes four groups intended to investigate the effect of piranha treatment and EGCG coating: a control group of PEEK discs with no treatment (C), PEEK samples treated with piranha solution (P), a group of PEEK samples coated with EGCG (E), and a group of PEEK samples treated with piranha solution and coated with EGCG (PE). Surface roughness, wettability, and microhardness were assessed through statistical analysis. Results. Piranha treatment increased surface roughness, while EGCG coating moderated it, resulting in an intermediate roughness in the PE group. EGCG significantly improved wettability, as indicated by the reduced contact angle. Microhardness increased by about 20 in EGCG-coated groups compared to noncoated groups. Statistical analysis confirmed significant differences between groups in all tests. Conclusion. This study demonstrates the potential of EGCG coating to enhance the surface properties of PEEK as dental implants. The combined piranha and EGCG modification approach shows promise for improved osseointegration, although further vivo research is necessary. Surface modification techniques hold the key to optimizing biomaterial performance, bridging the gap between laboratory findings and clinical implementation in dental implantology.
- 8 April 2024
- Published by Wiley in BioMed Research International
- Vol. 2024, 1-11
Open AccessEvaluation of High-Performance Polyether Ether Ketone Polymer Treated with Piranha Solution and Epigallocatechin-3-Gallate Coating
Background. Dental implantation has become a standard procedure with high success rates, relying on achieving osseointegration between the implant surface and surrounding bone tissue. Polyether ether ketone (PEEK) is a promising alternative to traditional dental implant materials like titanium, but its osseointegration capabilities are limited due to its hydrophobic nature and reduced surface roughness. Objective. The aim of the study is to increase the surface roughness and hydrophilicity of PEEK by treating the surface with piranha solution and then coating the surface with epigallocatechin-3-gallate (EGCG) by electrospraying technique. Materials and Methods. The study includes four groups intended to investigate the effect of piranha treatment and EGCG coating: a control group of PEEK discs with no treatment (C), PEEK samples treated with piranha solution (P), a group of PEEK samples coated with EGCG (E), and a group of PEEK samples treated with piranha solution and coated with EGCG (PE). Surface roughness, wettability, and microhardness were assessed through statistical analysis. Results. Piranha treatment increased surface roughness, while EGCG coating moderated it, resulting in an intermediate roughness in the PE group. EGCG significantly improved wettability, as indicated by the reduced contact angle. Microhardness increased by about 20 in EGCG-coated groups compared to noncoated groups. Statistical analysis confirmed significant differences between groups in all tests. Conclusion. This study demonstrates the potential of EGCG coating to enhance the surface properties of PEEK as dental implants. The combined piranha and EGCG modification approach shows promise for improved osseointegration, although further vivo research is necessary. Surface modification techniques hold the key to optimizing biomaterial performance, bridging the gap between laboratory findings and clinical implementation in dental implantology.
- Open Access
- 20 September 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-8
Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
Background. Polyetheretherketone (PEEK) is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10mm diameter and 2mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no acid treatment was used; the second group undergoes sulfuric acid treatment. The remaining three groups were treated with Piranha solution; each group used a different concentration (1:3, 1:5, and 1:7 hydrogen peroxide to sulfuric acid, respectively). The period of treatment was 60s for all groups. Wettability and surface roughness tests were done for the five groups. In statistical analysis, ShapiroWilk test was used to check the assumption of normality and to determine the statistical significance among groups; a one-way analysis of variance was employed. Subsequently, for multiple comparisons, Tukeys honestly significant difference post hoc test was performed. Results. The Piranha solution treatment groups showed a higher wettability compared to the control group and the group treated with sulfuric acid. Additionally, the Piranha solution treatment with a higher concentration of hydrogen peroxide (1:3) resulted in greater improvement in surface roughness compared to the control group and the lower concentration groups (1:5 and 1:7), while the sulfuric acid treated group showed the highest surface roughness. Conclusion. The results of this study suggest that the piranha solution can be an effective method for improving the surface characteristics of PEEK to be used in different dental applications, especially as a dental implant material, due to the increase in wettability and surface roughness.
- 20 September 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-8
Open AccessImproving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
Background. Polyetheretherketone (PEEK) is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10mm diameter and 2mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no acid treatment was used; the second group undergoes sulfuric acid treatment. The remaining three groups were treated with Piranha solution; each group used a different concentration (1:3, 1:5, and 1:7 hydrogen peroxide to sulfuric acid, respectively). The period of treatment was 60s for all groups. Wettability and surface roughness tests were done for the five groups. In statistical analysis, ShapiroWilk test was used to check the assumption of normality and to determine the statistical significance among groups; a one-way analysis of variance was employed. Subsequently, for multiple comparisons, Tukeys honestly significant difference post hoc test was performed. Results. The Piranha solution treatment groups showed a higher wettability compared to the control group and the group treated with sulfuric acid. Additionally, the Piranha solution treatment with a higher concentration of hydrogen peroxide (1:3) resulted in greater improvement in surface roughness compared to the control group and the lower concentration groups (1:5 and 1:7), while the sulfuric acid treated group showed the highest surface roughness. Conclusion. The results of this study suggest that the piranha solution can be an effective method for improving the surface characteristics of PEEK to be used in different dental applications, especially as a dental implant material, due to the increase in wettability and surface roughness.