Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ali Mohammad Ali Aljafery has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Aluminosilicate Clay Nanofiller Reinforcement on the Flexural Strength, Surface Hardness, Surface Roughness and Microstructure of Auto-Polymerized PMMA Denture Base Resin: An In Vitro Study

    by Hasanen Ali AlNamel, Ali Mohammad Ali Aljafery, Mohammed Hussein M. Alsharbaty, Mohammed A. Alsmael, Sabreen Waleed Ibrahim, Manar E. Al-Samaray

    Background/Objectives: Auto-polymerized polymethyl methacrylate (PMMA) is widely used in denture repair, relining, and base-plate fabrication but is susceptible to fracture due to limited flexural strength and fatigue resistance. This in vitro study investigated the concentration-dependent effects of synthetic aluminosilicate clay (ASC) nanoparticles on the flexural strength, Vickers hardness, surface roughness, and microstructure of auto-polymerized PMMA. Methods: A total of 120 specimens of SR Triplex Cold were prepared with 0 (control), 1, 3, or 5 wt.% ASC (50–100 nm; n = 30/group). ASC was dispersed in the monomer by probe sonication for 10 min. After pressure curing and storage in distilled water at 37 °C for 7 days, flexural strength, Vickers hardness, and surface roughness (Ra) were measured (n = 10/test/group). Microstructural characterization employed SEM, EDX, and XRD. Data were analyzed using ANOVA with appropriate post hoc tests (α = 0.05). Results: ASC concentration significantly affected all three properties (p < 0.001). At 1 wt.% ASC, flexural strength increased from 61.50 ± 3.37 to 79.70 ± 2.11 MPa (+29.6%), and hardness increased from 84.39 ± 3.81 to 97.84 ± 2.56 VHN. At 3 and 5 wt.%, these properties declined to 52.60 ± 3.75 and 31.70 ± 2.83 MPa, and to 63.97 ± 2.94 and 27.73 ± 2.62 VHN, respectively. Surface roughness increased with ASC concentration, from 0.102 ± 0.012 µm (control) to 0.195 ± 0.013, 0.245 ± 0.022, and 0.327 ± 0.035 µm at 1, 3, and 5 wt.%, respectively. SEM revealed favorable particle dispersion, crack deflection, and particle bridging at 1 wt.%, whereas higher concentrations promoted agglomeration, microvoid formation, and interfacial debonding. XRD confirmed the coexistence of the amorphous PMMA phase and crystalline aluminosilicate reflections. Conclusions: Under the conditions tested, 1 wt.% ASC provided the most favorable balance of mechanical and surface properties, improving flexural strength and hardness while maintaining Ra below 0.2 µm. Higher concentrations compromised mechanical performance, with the 3 and 5 wt.% groups falling below the minimum flexural strength for Type 2 polymers. The findings suggest that reinforcement depends primarily on particle dispersion and interfacial stress transfer rather than chemical modification of the PMMA backbone.

  • Osseointegration and Histopathological Evaluation of Titanium–Titanium Diboride Composite Compared to Pure Titanium Implant Materials Prepared by Powder Metallurgy (In Vivo Study)

    by Ali Mohammad Ali Aljafery, Abdalbseet A. Fatalla, Julfikar Haider

    The efficacy and osseointegration rate of an implant depend on its biocompatibility. Modern implantology seeks fast and reliable osseointegration, which is essential for clinical success. The objective of this research was to assess the osseointegration and biocompatibility of a titanium–titanium diboride composite (Ti‐TiB2) in rabbits in contrast to those of pure titanium (Ti). A total of 64 cylindrical implant specimens were fabricated, consisting of two sets: pure Ti (32 implants) and Ti‐TiB2 composite (32 implants). In this study, two implants were implanted per tibia (left and right tibias) in 16 white male New Zealand rabbits, for a total of four implants per rabbit (4 × 16 = 64 implants). A pushout test was used to assess implant specimen‐bone bonding after 2 and 6 weeks of healing. The experiment utilized five rabbits per healing phase, which means that 20 implants per time point were used for the pushout tests. (10 for pure Ti and 10 for the composite). Histology was used to examine the tissue response to biocompatibility, and histomorphometry was used to measure new bone growth at the two time points. With three rabbits per time point, 12 implants were employed for the histological analyses. After implantation, the pushout shear strength results revealed that the mean shear strength of the Ti‐TiB2 implant specimens (5.4 ± 0.029 MPa for 2 weeks, 7.9 ± 0.029 MPa for 6 weeks) was statistically greater (p < 0.0001) than that of the pure Ti implant specimens (5.1 ± 0.015 MPa for 2 weeks, 6.6 ± 0.047 MPa for 6 weeks). After 2 weeks, woven bone tissues were observed around the pure titanium implants, and active osteoid tissue around the composite implants exhibited significant differences in new bone formation areas (NBFAs) (0.54 ± 0.004 mm2 for Ti and 0.65 ± 0.003 mm2 for the composite). After 6 weeks, there was new bone formation with osteocytes around the pure titanium implants (NBFA of 2.44 mm2) and osteoid maturation with the observation of reversal lines around the composite implants (NBFA of 2.89 mm2). The developed Ti‐TiB2 material was biocompatible and demonstrated superior bone growth compared to that of the pure Ti materials after 2 and 6 weeks.


  • Open Access

    Cytotoxicity, Corrosion Resistance, and Wettability of Titanium and Ti-TiB2 Composite Fabricated by Powder Metallurgy for Dental Implants

    by Ali Mohammad Ali Aljafery, Abdalbseet A. Fatalla, Julfikar Haider

    Objectives: Orthopedics and dentistry have widely utilized titanium alloys as biomaterials for dental implants, but limited research has been conducted on the fabrication of ceramic particle-reinforced Ti composites for further weight reductions. The current study compared titanium–titanium diboride metal composites (Ti-TiB2) with pure titanium (processed by powder metallurgy) in terms of toxicity, corrosion resistance, and wettability. Methods: First, cell lines of a primary dermal fibroblast normal human adult (HDFa) were used to test the cytocompatibility (in vitro) of the composite and pure Ti using an indirect contact approach. Corrosion testing was performed for the materials using electrochemical techniques such as potentiodynamic polarization in a simulated bodily fluid (SBF) in conjunction with a three-electrode electrochemical cell. The entire set of experimental tests was conducted according to the ASTM F746-04 protocol. The contact angles were measured during wettability testing in accordance with ASTM D7334-08. An X-ray diffractometer (XRD) was used to catalog every phase that was visible in the microstructure. A scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to determine the chemical composition. Results: The cytotoxicity tests revealed that there was no detectable level of toxicity, and there was no significant difference in the impact of either of the two materials on the viability of human fibroblasts. An increase in the corrosion resistance of the composite (0.036 ± 0.0001 mpy (millimeters per year)) demonstrated the development of a passive oxide coating. According to the findings, the composites showed a greater degree of hydrophilicity (contact angle 44.29° ± 0.28) than did the pure titanium (56.31° ± 0.47). Conclusions/Significance: The Ti-TiB2 composite showed no toxicity and better corrosion resistance and wettability than did pure Ti. The composite could be a suitable alternative to Ti for applications involving dental implants.


  • Open Access

    Powder Metallurgy Preparation and Characterization of Titanium-Titanium Diboride Composite Targeted for Dental Implant

    by Ali Mohammad Ali Aljafery, Abdalbseet A. Fatalla, Julfikar Haider

    Due to the advantages over other metallic materials, such as superior corrosion resistance, excellent biocompatibility, and favorable mechanical properties, titanium, its alloys and related composites, are frequently utilized in biomedical applications, particularly in orthopedics and dentistry. This work focuses on developing novel titanium-titanium diboride (TiB2; ceramic material) composites for dental implants where TiB2 additions were estimated to be 9 wt.%. In a steel mold, Ti-TiB2 composites were fabricated using a powder metallurgy technique and sintered for five hours at 1200 °C. Microstructural and chemical properties were analyzed by energy dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), and X-ray diffraction (XRD) to evaluate the impact of the TiB2 ceramic addition. Compressive strength, Brinell hardness, porosity, and density, among other mechanical and physical properties, were also measured and characterized. It has been found that adding TiB2 to Ti increases its porosity (35.53%), compressive strength (203.04 MPa), and surface hardness (296.3 kg/mm2) but decreases its density (3.79 gm/cm3). The lightweight and strong composite could be suitable for dental implant applications.


  • Open Access

    The Effects of Incorporating Ag-Zn Zeolite on the Surface Roughness and Hardness of Heat and Cold Cure Acrylic Resins

    by Ali M. Aljafery, Ola M. Al-Jubouri, Zena J. Wally, Rajaa M. Almusawi, Noor H. Abdulrudha, Julfikar Haider

    One of the most widely used materials for the fabrication of prosthetic dental parts is acrylic resin. Its reasonable mechanical and physical properties make it a popular material for a wide range of dental applications. Recently, many attempts have been made to improve the mechanical and biological properties of this material, such as by adding fibres, nanoparticles, and nanotubes. The current study aimed to evaluate the effects of adding an antimicrobial agent, Ag-Zn zeolite, on the surface roughness and hardness of the denture base resins. Ag-Zn zeolite particles were chemically prepared and added at different concentrations (0.50 wt.% and 0.75 wt.%) to the heat cure (HC) and cold cure (CC) acrylic resins. Zeolite particles were characterized and confirmed using X-ray diffraction (XRD) and Energy-Dispersive X-ray Spectroscopy (EDX) attached with a Scanning Electron Microscope (SEM). Sixty disk shape specimens (40 mm diameter and 2 mm thickness) were fabricated from the HC and CC resins with and without the zeolite. All the specimens were divided into two main groups based on the acrylic resins, then each was subdivided into three groups (n = 10) according to the concentration of the Ag-Zn zeolite. A surface roughness and a hardness tester were used to measure the surface finish and hardness of the specimens. The analysed data showed that the surface roughness values significantly decreased when 0.50 wt.% and 0.75 wt.% zeolite were incorporated in the HC resin specimens compared to the control group. However, this reduction was not significant in the case of CC resin, while the surface hardness was significantly improved after incorporating 0.50 wt.% and 0.75 wt.% zeolite for both the CC and HC resins. Incorporating Ag-Zn zeolite with acrylic resin materials could be beneficial for improving their surface finish and resistance to surface damage as defined by the higher hardness.