Yuan Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuan Wei has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Guangyu Zhu
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
2 shared publications - Jia Yin
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
2 shared publications - Junxia Wu
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
2 shared publications - Peilin He
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
2 shared publications - Fafu Ni
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
1 shared publication Hongming Xie
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
1 shared publication
Latest Publications
- 1 June 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (6)
Development of a non-intercepting weak beam current measurement electronics for Heavy Ion Accelerator Facility in Lanzhou
Non-destructive measurements of low-intensity charged particle beams are particularly challenging for beam diagnostics. At the Heavy Ion Accelerator Facility in Lanzhou (HIRFL), beams with weak currents below 1 µA are often provided for experiments. The detection of such low beam current is below the threshold of typical standard beam current transformers. Therefore, a low-intensity monitoring system is developed by using a sensitive capacitive pick-up (PU) and low-noise electronics. This device measures beam currents by digitally analyzing the amplitude of the PU signals using a homodyne detection scheme. During lab tests, the amplitude nonlinearity is <0.5% in the operational range of 1 nA–45 µA and the amplitude resolution is 0.94 nA. At present, four measurement systems for low beam currents are installed at HIRFL for the monitoring of standard operating conditions with low beam currents below 1 µA. After an absolute calibration with a Faraday cup, it can be used for accurate beam intensity measurement with a current resolution of about 1 nA.
- 1 June 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (6)
Development of a non-intercepting weak beam current measurement electronics for Heavy Ion Accelerator Facility in Lanzhou
Non-destructive measurements of low-intensity charged particle beams are particularly challenging for beam diagnostics. At the Heavy Ion Accelerator Facility in Lanzhou (HIRFL), beams with weak currents below 1 µA are often provided for experiments. The detection of such low beam current is below the threshold of typical standard beam current transformers. Therefore, a low-intensity monitoring system is developed by using a sensitive capacitive pick-up (PU) and low-noise electronics. This device measures beam currents by digitally analyzing the amplitude of the PU signals using a homodyne detection scheme. During lab tests, the amplitude nonlinearity is <0.5% in the operational range of 1 nA–45 µA and the amplitude resolution is 0.94 nA. At present, four measurement systems for low beam currents are installed at HIRFL for the monitoring of standard operating conditions with low beam currents below 1 µA. After an absolute calibration with a Faraday cup, it can be used for accurate beam intensity measurement with a current resolution of about 1 nA.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Stochastic cooling notch filter developments for the high-precision spectrometer ring in the high intensity heavy-ion accelerator facility project
Stochastic cooling of the high-precision spectrometer ring (SRing) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) project in China, which is used mainly for experiments with radioactive fragment beams, is applied to speed up the cooling process of a stored ion beam. In this article, a new coaxial-type notch filter with an amplitude equalizer in the long branch and an optical-type notch filter with phase-stabilized optical fiber are discussed and evaluated for the SRing stochastic cooling system. Both prototypes of coaxial and optical notch filters are fabricated and tested. The minimum notch depth of coaxial and optical notch filters reaches to 26 and 40 dB, respectively. The performance of both coaxial notch filter and optical fiber notch filter is presented in this work. These developments will be used not only for the longitudinal stochastic cooling system but also have potential for the beam feedback system.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Stochastic cooling notch filter developments for the high-precision spectrometer ring in the high intensity heavy-ion accelerator facility project
Stochastic cooling of the high-precision spectrometer ring (SRing) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) project in China, which is used mainly for experiments with radioactive fragment beams, is applied to speed up the cooling process of a stored ion beam. In this article, a new coaxial-type notch filter with an amplitude equalizer in the long branch and an optical-type notch filter with phase-stabilized optical fiber are discussed and evaluated for the SRing stochastic cooling system. Both prototypes of coaxial and optical notch filters are fabricated and tested. The minimum notch depth of coaxial and optical notch filters reaches to 26 and 40 dB, respectively. The performance of both coaxial notch filter and optical fiber notch filter is presented in this work. These developments will be used not only for the longitudinal stochastic cooling system but also have potential for the beam feedback system.