KAK.YU. Andriienko

K.YU. Andriienko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


K.YU. Andriienko has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CLINICAL-FUNCTIONAL EVALUATION OF ORTHOPEDIC TREATMENT OF PATIENTS ON DENTAL IMPLANTS

    by I.V. Yanishen, K.YU. Andriienko, A.V. Pohorila, R.V. Kuznetsov, N.V. Gorbatovska

    Modern prosthodontics is characterized by the rapid development of digital technologies that encompass virtually all stages of prosthetic treatment, from initial diagnosis to the fabrication and fixation of definitive prosthetic restorations. Despite the active implementation of digital technologies into clinical practice, the issue of comparative evaluation of conventional and digital impression techniques during implant-supported prosthetic treatment remains relevant. In this regard, the comparative clinical and functional assessment of the outcomes of prosthetic rehabilitation on dental implants using conventional and digital impression techniques represents an important scientific and practical task aimed at improving contemporary prosthetic rehabilitation protocols. Objective. To increase the effectiveness of prosthetic rehabilitation in patients with partial edentulism through the fabrication of implant-supported fixed prosthetic restorations. Materials and Methods. The study was conducted at the Department of Prosthetic Dentistry and the University Dental Center of Kharkiv National Medical University. A total of 48 patients aged 28 to 67 years with partial secondary edentulism who underwent prosthetic rehabilitation using dental implants were included in the study. All patients were divided into two clinical groups according to the implant system used. Ethical considerations were addressed in accordance with the legislation of Ukraine, Articles 7, 8, and 12 of the Law of Ukraine “On Medicinal Products” (1996), the principles of Good Clinical Practice (International Council for Harmonisation Good Clinical Practice, ICH GCP, 2008), Order of the Ministry of Health of Ukraine No. 690 dated September 23, 2009, “On Approval of the Procedure for Conducting Clinical Trials of Medicinal Products and Expert Evaluation of Clinical Trial Materials and the Standard Regulations on Ethics Committees,” with amendments and additions, as well as the Declaration of Helsinki of the World Medical Association (1964, latest revision – 2024). The article is a fragment of the planned research project of the Department of Prosthetic Dentistry of Kharkiv National Medical University entitled “Integration of Modern Achievements in Medicine, Materials Science, and Technologies of Diagnosis, Treatment, and Rehabilitation of Patients in the Clinic of Prosthetic Dentistry” (State Registration No. 0125U000939, implementation period: 2025–2027; Principal Investigator – Head of the Department of Prosthetic Dentistry, Doctor of Medical Sciences, Professor I.V. Yanishen). All patients were in satisfactory general health and had no absolute contraindications to dental implantation and subsequent prosthetic treatment. After completion of osseointegration and maturation of peri-implant tissues, the prosthetic stage of treatment was performed. Within each clinical group, two impression protocols were applied: a conventional technique using an open-tray impression and A-silicone impression material, and a digital technique using an intraoral scanner and scan bodies. Follow-up examinations were performed at 1, 3, 6, and 12 months after fixation of the prosthetic restorations. Statistical analysis was carried out using methods of descriptive and inferential statistics with determination of the mean value (M), standard deviation (SD), Student’s t-test, and the level of statistical significance at p < 0.05. Results A total of 106 dental implants were placed, including 52 Alfabio implants and 54 Megagen implants. The average number of implants per patient was 2.21 ± 0.8. During follow-up examinations at 1, 3, 6, and 12 months, no cases of implant loss or impaired osseointegration were recorded, resulting in an implant survival rate of 100%. The obtained results are consistent with contemporary studies and confirm the high effectiveness of digital technologies in implant-supported prosthodontics. The use of intraoral scanners allows optimization of both clinical and laboratory stages of treatment, improves the accuracy of prosthetic restorations, and enhances patients’ quality of life. Conclusions. The use of digital intraoral scanning reduces the duration of the clinical impression-taking stage by 1.9 times compared with conventional A-silicone impression materials. Implant-supported fixed prosthetic restorations provide a statistically significant improvement in masticatory efficiency, as confirmed by functional assessment at all follow-up periods. Following prosthetic rehabilitation, patients demonstrated a substantial improvement in quality-of-life indicators according to the treatment satisfaction questionnaire.

  • Open Access

    Comparative evaluation of acrylic base of complete removable dentures using vacuum post-polymerization method

    by I.V. Yanishen, K.YU. Andrienko, O.L. Fedotova, A.V. Pogorila, D.P. Kapelko, N.V. Gorbatovska

    Background. Complete secondary edentulism of the mandible remains one of the most common clinical problems in middle-aged and elderly patients and has signi-ficant medical and social importance. Comparative clinical and functional evaluation using vacuum post-polymerization treatment is scientifically substantiated and practically significant. Purpose – to improve the effectiveness of orthopedic treatment of patients with complete edentulism through comparative clinical and functional evaluation of complete removable dentures and implant-supported overdentures with vacuum-processed acrylic bases, and by analyzing oral fluid parameters at different stages of rehabilitation. Materials and methods. Group I included 16 patients treated with complete removable laminar dentures with an acrylic base manufactured using vacuum post-polymerization treatment. Group II consisted of 17 patients who underwent orthopedic treatment with implant-supported overdentures retained on two intraosseous dental implants with a locator attachment system. Results. During the observation period, adaptation occurred gradually with positive dynamics, but was better in Group II. After 1 month, denture stability in Group I was 68.7%, while in Group II it was 94.1%; after 3–6 months, stability in Group II reached 100% (p < 0.05). Masticatory efficiency increased by 28.6% in Group I and by 46.3% in Group II. The OHIP-14 score decreased by 32.4% and 51.7%, respectively. By 6 months, biochemical parameters of oral fluid normalized faster in Group II (p < 0.05). Conclusions. Implant-supported overdentures with a vacuum-treated acrylic base provide more stable functional characteristics, faster restoration of masticatory function, and better quality of life compared with conventional complete removable laminar dentures.

  • Open Access

    PREPARATION OF ORTHOPAEDIC TREATMENT FOR PATIENTS WITH PERIODONTAL DISEASES AND REDUCED OCCLUSAL HEIGHT

    by K.YU. Andriienko, O.L. Fedotova, A.V. Pohorila, I.L. Dudina, O.V. Sidorova

    Periodontology is rapidly evolving, integrating advances in fundamental sciences, pharmacology, and dental materials. A thoroughly planned orthopaedic treatment protocol, aimed at restoring dentition defects and stabilising remaining teeth, normalises occlusal load, periodontal trophism, and reparative processes, thereby enhancing the effectiveness of periodontal disease management. The aim of our study was to improve the effectiveness of prosthetic treatment in patients with periodontal diseases accompanied by a decrease in interalveolar height through the use of a splint-cap. Participants and methods. Orthopaedic treatment of patients with periodontal tissue diseases was carried out at the Department of Prosthetic Dentistry of the University Dental Centre of Kharkiv National Medical University. To achieve the study objectives, 33 patients aged 45-70 years were examined and treated. The study included patients with periodontal diseases who underwent treatment according to the Jankelson technique followed by the fabrication of splint-caps. Depending on the applied orthopaedic treatment approach, the patients were divided into two clinical groups. Participants and Methods. Orthopaedic treatment of patients with periodontal diseases was performed at the Department of Prosthetic Dentistry of the University Dental Centre of Kharkiv National Medical University. To achieve the study objectives, 33 patients aged 45–70 years were examined and treated. The study included patients with periodontal disease who underwent treatment according to the Jankelson technique, followed by the fabrication of splint-caps. Depending on the orthopaedic treatment approach applied, the patients were divided into two clinical groups. Results. A reduction in tooth mobility was observed predominantly in areas previously affected by pronounced occlusal overload. In the first study group, positive dynamics of this parameter were recorded in 14 patients (82.35%), whereas in the comparison group improvement was noted in 11 patients (68.75%). A decrease in periodontal pocket depth of at least 1 mm, according to control probing, was observed in 13 patients in the first study group (76.47%) and in 11 patients in the second group (68.75%).In the first study group, normalization of masticatory muscle tone persisted throughout the entire observation period in 16 patients (94.12%). In the second group, a similar outcome was observed in 15 patients (93.75%); however, some of them required repeated correction of occlusal contacts. Conclusion. Comparative analysis of the two patient groups demonstrated that fixed splint-caps provide more effective stabilization of the mandibular neuromuscular position, more even distribution of occlusal load, greater periodontal tissue stability, and faster patient adaptation compared with removable splints. Fixed splint-caps significantly improved occlusal contacts, mandibular spatial position, and periodontal tissue condition (p < 0.05), while reducing the need for additional adjustments. These findings support their use as an effective component of comprehensive orthopaedic treatment for patients with periodontal disease and reduced interalveolar height.

  • Open Access

    Influence of tension and deformation indicators on the quality of removable constructions acrylic basis

    by K.YU. Andrienko

    Background. The question of distribution of masticatory pressure is one of the main branches in quali­tive manufacturing of removable constructions. With the development of software, as well as with the increase in the power of computer technology has also spread to the problems of biomechanics, in particular the biomechanics of the human oral cavity. The aim of our study was to analyze the results of using the method of finite element techniques with the purpose to improve the quality of prosthetic treatment by correct modeling constructional denture elements. Materials and Methods. The study involved 45 patients aged 44–73 years (mean age 59.2±4.3) treated with complete laminar prosthetic constructions for the upper jaw and lower jaw. A powerful method was developed to solve the problems of the theory of elasticity – the finite element method. The main idea is that the body under the study is divided into a finite number of subdomains or elements on which the desired continuous function is approximated by a polynomial (consists of piecewise continuous functions). A two-dimensional quadrangular element with four nodes was chosen as the partition element. Dividing it into elements and further solving the problem was in the ANSYS Mechanical APDL package (USA). Results. Regarding the calibration of the ultimate displacements of nodal points and as a result of the distribution of masticatory pressure under the basis of a complete removable dentures on the tissues of the prosthetic area, the average values of each plane were as follows: for section PM1 – the plane with high pressure was ([675298.14±5.21] m2K). Taking the PM2 region, the values were slightly higher ([369743.3±3.9] m2K) and ([735356.34±4.52] m2K), respectively. Conclusions. Our findings suggest direct relationship between the using of mathematical calculation of material volume, volume deformation, potential data and elasticity theory as auxiliary element in the manufacture of removable dentures and, as a result, direct influence on level of quality of following constructions. Keywords: orthopedic treatment, finite element method, complete removable dentures, tension theory, deformation.


  • Open Access

    Comparative assessment of physical and mechanical indicators of packing materials of complete removable dentures

    by K.Yu. Andrienko

    In press Successful dental rehabilitation of a patient with complete removable dentures depends not only on a number of features of the selected design and clinical conditions of the patient's prosthetic area. Also on the manufacturing technology of the materials used for its manufacture. The purpose of our study was a comparative assessment of the physical and mechanical properties of doped packing materials for removable denture structures using an improved method. An alloyed packing material based on gypsum and supergypsum, modified with nitrile rubber latexes and organosilicon emulsion, was developed. The selected modifiers differ in their structure, group polarity and lyophilicity. The comparative analysis of the quality of auxiliary dental materials included a generalization of the results of a laboratory study of the physical and mechanical properties of various types of plaster. In the system of qualitative assessment of plasters, the indicative properties of auxiliary materials were investigated: "ORTHOGYPS", "Gypsum highness type 10", "Base Stone", provided by ISO 6873, which are divided by us into technological (defining features of the material packaging process) and physical and mechanical (total working time, structuring time, relative expansion during structuring, relative expansion after structuring, compressive strength, linear shrinkage). As a result, it was determined that the developed modified components of the alloy packing material, in turn, provided acceptable accuracy of the base of the removable dentures, which corresponded to the working model due to the improvement of the physical and mechanical properties of the packing material and, as a result, improved manufacturability of removable orthopedic structures of dental prostheses. Keywords: orthopedic treatment, physical and mechanical properties, complete removable dentures, modifier, gypsum mixture. In press Однією з найважливіших завдань сучасної ортопедичної стоматології є підвищення ефективності лікування пацієнтів із повною та частковою відсутністю зубів та підвищення рівня якості їх життя за рахунок правильного та послідовного виготовлення знімних ортопедичних конструкцій зубних протезів. Метою нашого дослідження було порів­няльна оцінка показників фізико-механічних властивостей легованих пакувальних матеріалів знімних конструкцій зубних протезів за удосконаленою методикою. Був розроблений легований пакувальний матеріал на основі гіпсу та супергіпсу, модифікований латексами нітрильних каучуків та кремнійорганічною емульсією. Вибрані модифікатори різні за своєю будовою, полярністю груп та ліофільністю. Основним моментом проведення порівняльного аналізу, що визначав якість допоміжних стоматологічних матеріалів, була конкретизація показників фізико-механічних властивостей різних видів гіпсу шляхом їх лабораторного вивчення. В системі кваліметричної оцінки гіпсів досліджено індикативні властивості допоміжних матеріалів ("ORTHOGYPS", «ГВ-Г-10 А-III», "Base Stone"), що передбачено ISO-6873. Індикатори були розділені нами на технологічні (визначальні особливості процесу пакування матеріалу) та фізико-механічні (показник загального робочого часу, часу структуризації, показник відносного розширення під час структуризації, показник відносного розширення після моменту структуризації, міцність стискання, показник лінійної усадки). Як результат було визначено, що розроблені модифіковані компоненти легованого пакувального матеріалу, в свою чергу, забезпечували прийнятну точність базису знімного пластинкового протеза, яка відповідала робочій моделі за рахунок покращення фізико-механічних властивостей пакувального матеріалу і, відповідно, технологічності знімних ортопедичних конструкцій зубних протезів. Ключові слова: ортопедичне лікування, фізико-механічні властивості, повний знімний пластинковий протез, модифікатор, гіпсова суміш.

  • Open Access

    Study of the influence of modifier concentrations on the technological and physico-mechanical properties of doped packing materials for complete removable dentures manufacturing

    by I.V. Yanishen, K.Yu. Andrienko

    In press Successful dental rehabilitation of a patient with complete removable dentures depends not only on a number of features of the selected design and clinical conditions of the patient's prosthetic area. It depends also on the technology of developing materials used for its manufacture. The purpose of our study was to study the influence of the number of modifiers on technological and physical -mechanical properties of doped packing materials in the manufacture of removable structures of dental prostheses according to the improved method. We performed orthopedic treatment of 45 patients aged 50 to 75 years (average age 59.5±3.2) with complete removable dentures for the upper and lower jaws. We determined the values of the concentrations most favorable to the addition of modifiers in the researched doped packaging material, the introduction of which into the technological process makes it possible to have better indicators of physical and mechanical properties, namely: hydrophilic ratio, total working time, structuring time, relative expansion during structuring, strength compression and roughness index of gypsum samples. If the structuring time of the standard gypsum mixture solution according to ISO-6873 is (4.0±0.2) minutes, then the investigated compositions "Base Stone", "Gypsum highness type 10" and "ORTHOGYPS" with the addition of modified samples of organosilicon emulsion, butadiene styrene latex and polyvinyl acetate dispersion when the minimum dose of modifier concentrations, the average value of which was 0.08–0.10%, was introduced, this time was extended by an average of 2–2.5 times. It was determined that the developed modified components of the alloyed packing material, in turn, provided acceptable accuracy of the base of the removable denture, which corresponded to the working model due to the improvement of the physical and mechanical properties of the packing material. Keywords: modifier compound, complete acrylic removable constructions, gypsum mixture, prosthetic dental rehabilitation. In press Успішна стоматологічна реабілітація пацієнта повними знімними пластинковими протезами залежить не тільки від ряду особливостей обраної конструкції та клінічних умов протезного ложа пацієнта, а й від технології розробки матеріалів, що використовуються для її виготовлення. Метою нашого дослідження було вивчення впливу кількості модифікаторів на технологічні та фізико-механічні властивості легованих пакувальних матеріалів при виготовленні знімних конструкцій зубних протезів за удосконаленою методикою. Нами було проведено ортопедичне лікування 45 пацієнтів віком від 50 до 75 років (середній вік склав [59,5±3,2] років) повними знімними протезами на верхню та нижню щелепи. Нами були визначені значення найбільш сприятливих до додавання концентрацій модифікаторів у досліджуваному легованому пакувальному матеріалі, впровадження яких у технологічний процес дає змогу мати кращі показники фізико-механічних властивостей, а саме: гідрофільне співвідношення, загальний робочий час, час структуризації, відносне розширення при структуризації, міцність стиснення та показник шорсткості гіпсових зразків. Якщо час структуризації стандартного розчину гіпсової суміші згідно ISO-6873 складає (4,0±0,2) хвилини, то для досліджуваних композицій "Base Stone", «ГВ-Г-10А-III» та "ORTHOGYPS" з додаванням модифікованих зразків КЕ-10-01, ПВС, БС-65-ГП та ПВА при введенні мінімальної дози концентрацій модифікатору, середнє значення складало 0,08–0,10 %. Цей час подовжується в середньому у 2–2,5 рази. Було визначено, що розроблені модифіковані компоненти легованого пакувального матеріалу, в свою чергу, забезпечували прийнятну точність базису знімного пластинкового протеза, що відповідало робочій моделі за рахунок підвищення фізико-механічних властивостей пакувального матеріалу. Ключові слова: модифікуюча добавка, знімні пластинкові зубні протези, гіпсова суміш, ортопедична стоматологічна реабілітація.