Michael J. Liesenfelt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael J. Liesenfelt has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chloe A. Browning
Univ Tennessee, Dept Nucl Engn, 863 Neyland Dr, Knoxville, TN 37902 USA
2 shared publications David Hellmann
University of Tennessee, Knoxville, USA
2 shared publicationsJason P. Hayward
University of Tennessee, Knoxville, USA
2 shared publications- Jason P. Hayward
Department of Nuclear Engineering, University of Tennessee, Knoxville, USA
2 shared publications - Jeff R. Preston
Y-12 Natl Secur Complex,301 Bear Creek Rd, Oak Ridge, TN 37830 USA
2 shared publications - Matthew R. Smalley
Min H Kao Dept Elect Engn & Comp Sci, 1520 Middle Dr, Knoxville, TN 37996 USA
2 shared publications
Latest Publications
- Open Access
- 7 August 2024
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 43 (3)
Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel
A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.
- 7 August 2024
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 43 (3)
Open AccessAnalysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel
A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.
- Open Access
- 7 June 2024
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 43 (3) , 1-13
High Energy X-Ray Source Characterization at 0.450, 3, 6, 9, and 15 MVp
As the availability and importance of high energy X-ray sources grows, accurate source characterizations provide critical information for field flatness corrections, beam hardening corrections, detector response corrections, and radiation shielding assessments. This study uses MCNP6.2 to create accurate high definition angular and energy dependent X-ray source definitions for the most common high energy industrial X-ray sources at 450 kVp, 3 MVp, 6 MVp, 9 MVp, and 15 MVp.
- 7 June 2024
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 43 (3) , 1-13
Open AccessHigh Energy X-Ray Source Characterization at 0.450, 3, 6, 9, and 15 MVp
As the availability and importance of high energy X-ray sources grows, accurate source characterizations provide critical information for field flatness corrections, beam hardening corrections, detector response corrections, and radiation shielding assessments. This study uses MCNP6.2 to create accurate high definition angular and energy dependent X-ray source definitions for the most common high energy industrial X-ray sources at 450 kVp, 3 MVp, 6 MVp, 9 MVp, and 15 MVp.
- Open Access
- 3 January 2024
- Published by Springer Nature in Research Square
High Energy X-ray Source Characterization at 0.450, 3, 6, 9, and 15 MVp
As the availability and importance of high energy X-ray sources grows, accurate source characterizations provide critical information for field flatness corrections, beam hardening corrections, detector response corrections, and radiation shielding assessments. This study uses MCNP6.2 to create accurate high definition angular and energy dependent X-ray source definitions for the most common high energy industrial X-ray sources at 450 kVp, 3 MVp, 6 MVp, 9 MVp, and 15 MVp.
- 3 January 2024
- Published by Springer Nature in Research Square
Open AccessHigh Energy X-ray Source Characterization at 0.450, 3, 6, 9, and 15 MVp
As the availability and importance of high energy X-ray sources grows, accurate source characterizations provide critical information for field flatness corrections, beam hardening corrections, detector response corrections, and radiation shielding assessments. This study uses MCNP6.2 to create accurate high definition angular and energy dependent X-ray source definitions for the most common high energy industrial X-ray sources at 450 kVp, 3 MVp, 6 MVp, 9 MVp, and 15 MVp.
- Open Access
- 21 September 2023
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 42 (4) , 1-11
Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel
Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $$\times $$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.- 21 September 2023
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 42 (4) , 1-11
Open AccessScalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel
Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $$\times $$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.