MSMatthew R. Smalley

Matthew R. Smalley

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthew R. Smalley has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

    by Christian X. Young, Chloe A. Browning, Ryan J. Thurber, Matthew R. Smalley, Michael J. Liesenfelt, Jason P. Hayward, Nicole McFarlane, Michael P. Cooper, Jeff R. Preston

    A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

  • Open Access

    Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

    by Christian X. Young, Chloe A. Browning, Ryan J. Thurber, Matthew R. Smalley, Michael J. Liesenfelt, Jason P. Hayward, Nicole McFarlane, Michael P. Cooper, Jeff R. Preston

    Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $$\times $$ × 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.


  • A Combined pH-Impedance System Suitable for Portable Continuous Sensing

    by Shaghayegh Aslanzadeh, Ava Hedayatipour, Matthew Smalley, Nicole McFarlane

    In this paper, a combined pH and impedance sensing system suitable for portable measurements is presented. The sensor outputs are converted directly to frequency or pulse width. The pH sensor is based on a voltage clamp topology that uses charging and discharging capacitors, voltage window comparators, and an SR-Latch to convert the output to frequency. The impedance to frequency sensor is based on current and voltage comparators and an SR-Latch. The pH system based on ISFET transistors is experimentally verified with on chip electrodes while the impedance sensor is characterized with discrete electronic components. The portable system is implemented with two chips and an external multi-electrode array into a portable system. Resistance, capacitance, and pH are experimentally measured using buffer solutions to simulate a water quality monitoring application. The system is implemented in a portable format and all modules, excluding the commercial microprocessor, consume an average power of 56 $ \mu W$ with an area of 0.006 mm $^{2}$ using a 180 nm technology.