MAMatthias Stephan Anders

Matthias Stephan Anders

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Matthias Stephan Anders has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multiparametric MRI radiomics for noninvasive risk stratification of pediatric neuroblastoma: a pilot study

    by M. S. Anders, F. Mollica, T. Meyer, R. Tahan, H. E. Deubzer, S. Veldhoen, C. Metz

    Neuroblastoma is the most common extracranial solid tumor in children, with risk stratification guiding therapy and prognosis. Although current risk stratification incorporates imaging-based staging, definitive risk assignment still relies on tissue and molecular characterization, highlighting the need for complementary noninvasive imaging biomarkers. The objectives were to evaluate the classification performance of multiparametric magnetic resonance imaging (MRI) radiomics for risk stratification of pediatric neuroblastoma and to determine how MRI sequences, feature-selection methods, and machine learning classifiers influence classification performance. This retrospective single-center feasibility study included 30 children with histologically confirmed neuroblastoma who underwent pre-treatment T1-, T2-, and diffusion-weighted MRI. From each sequence, 208 radiomic features were extracted from the whole-tumor volume and reduced using six feature-selection methods. Principal components of selected features trained six machine learning classifiers. Performance was assessed using a nested leave-one-out cross-validation framework, with predictions aggregated to one per patient before computing performance metrics, for binary classification of low/intermediate-risk versus high-risk neuroblastoma, using clinical risk classification as the reference standard, with pairwise differences evaluated by DeLong test and Benjamini–Hochberg correction. Among 30 children (mean age ± SD: 38 ± 40 months), the highest discrimination between risk groups was achieved using T2-weighted features and the combined T1w + T2w + ADC features, both with XGB (AUC = 0.88 ± 0.06 and 0.88 ± 0.07, respectively); however, the limited sample size prohibited the detection of significant differences between classifiers after correction for multiple comparisons. Features derived from T2-weighted and diffusion-weighted MRI contributed most to accurate classification. The chi-square feature selection method most frequently contributed to high-performing model configurations (30.8%). Multiparametric MRI radiomics based on whole-tumor volumes showed preliminary evidence of feasibility for noninvasive risk stratification of pediatric neuroblastoma, supporting its potential as a complementary imaging biomarker.

  • Open Access

    Image‐Derived Volumetry During Forced Expiration Using a 3D Fermat Looped, Orthogonally Encoded Trajectory

    by Sebastian Scheidel, Viktor Hartung, Matthias Stephan Anders, Corona Metz, Herbert Köstler, Simon Veldhoen, Tobias Wech

    Purpose: To enable MRI‐based nongated 3D depiction of forced expiration with both high spatio‐temporal resolution and fidelity of lung dynamics. Methods: An undersampled 3D Fermat looped, orthogonally encoded trajectory (FLORET) was optimized for nonsegmented dynamic acquisitions during forced expiration and a corresponding model‐based reconstruction pipeline promoting spatial and temporal total variation was implemented. The approach was first optimized and validated using a lung phantom, specifically constructed for this study and was then translated to in vivo measurements. This allowed high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm. Results: Volumes derived by segmenting the MR images of the phantom demonstrated excellent agreement with the air exchange measured directly at the phantom within the bore, therefore confirming the validity of the approach. In both phantom and in vivo experiments, the dynamic deflation process could be successfully depicted, confirming the potential for assessing forced expiration with 3D UTE FLORET MRI. From the segmented volumes in vivo, quantitative parameters were derived, including the duration of the dynamic phase (2.8 ± 0.2 s), the time to 90% deflation (1.8 ± 0.2 s), and the volume change within the first second (2.8 ± 0.2 L). Conclusion: The phantom and in vivo studies demonstrate, that the 3D FLORET trajectory can be utilized to study lung deflation during forced expiration with high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm using a TV‐regularized primal‐dual SENSE reconstruction. Acquisitions were performed for discrete distinct time frames, that is, no segmented k‐space filling across several respiratory cycles was used.

  • Open Access

    Time‐resolved mapping of myocardial stiffness using 2D multifrequency spiral MR elastography with and without external vibration

    by Matthias S. Anders, Carsten Warmuth, Tom Meyer, Helge Herthum, Mehrgan Shahryari, Jakob Schattenfroh, Corona Metz, Jan Bieling, Josef Pfeuffer, Simon Veldhoen, et al.

    Purpose: There is a clinical need for stiffness mapping of the heart; however, current cardiac magnetic resonance elastography (cMRE) has limited spatiotemporal resolution. Therefore, we developed 2D spiral multifrequency MRE of the human heart and conducted a study to analyze the consistency and reproducibility of motion‐encoding and stiffness mapping with and without external vibration.Methods: Eleven healthy volunteers were studied using single‐slice gradient‐echo spiral cMRE with cardiac triggering and encoding of harmonic shear wave fields at 70, 80, and 90 Hz frequency generated by either external drivers or endogenous heart motion. Tissue displacement was monitored synchronized to the cardiac cycle, and frequency‐resolved shear wave speed (SWS) maps were reconstructed as a proxy for left ventricular (LV) stiffness variations. After several days, all subjects underwent repeat scanning for reproducibility analysis based on intraclass correlation coefficients (ICCs).Results: cMRE with external vibration showed LV SWS to be highest in end‐systole (ES) (2.17 ± 0.23 m/s), followed by diastole (DIA) (1.94 ± 0.15 m/s) and isovolumetric contraction (IVC) (1.78 ± 0.18 m/s). ICCs decreased with distance from the R‐wave from excellent (0.93) in IVC to moderate (0.68) in ES. Without external vibration, sufficient LV harmonic displacement amplitudes permitted SWS reconstruction, resulting in similar SWS, but lower ICC values than with external vibration in IVC and ES.Conclusions: Multifrequency cMRE offers high spatiotemporal resolution and reproducibility with external vibration. In addition, the technique allows the encoding of endogenous shear waves during cardiac phases with pronounced wall motion.


  • Open Access

    Noninvasive assessment of portal pressure by combined measurement of volumetric strain and stiffness of in vivo human liver

    by Noah Jaitner, Yasmine Safraou, Matthias Anders, Jakob Schattenfroh, Tom Meyer, Biru Huang, Jakob Jordan, Oliver Boehm, Alfonso Caiazzo, Tobias Schaeffter, et al.


  • Open Access

    Rapid MR elastography of the liver for subsecond stiffness sampling

    by Matthias Anders, Tom Meyer, Carsten Warmuth, Josef Pfeuffer, Heiko Tzschaetzsch, Helge Herthum, Mehrgan Shahryari, Katja Degenhardt, Oliver Wieben, Sebastian Schmitter, et al.

    Purpose: Depicting the stiffness of biological soft tissues, MR elastography (MRE) has a wide range of diagnostic applications. The purpose of this study was to improve the temporal resolution of 2D hepatic MRE in order to provide more rapid feedback on the quality of the wavefield and ensure better temporal sampling of respiration‐induced stiffness changes.Methods: We developed a rapid MRE sequence that uses 2D segmented gradient‐echo spiral readout to encode 40 Hz harmonic vibrations and generate stiffness maps within 625 ms. We demonstrate the use of this technique as a rapid test for shear wave amplitudes and overall MRE image quality and as a method for monitoring respiration‐induced stiffness changes in the liver in comparison to 3D MRE and ultrasound‐based time‐harmonic elastography.Results: Subsecond MRE allowed monitoring of increasing shear wave amplitudes in the liver with increasing levels of external stimulation within a single breath‐hold. Furthermore, the technique detected respiration‐induced changes in liver stiffness with peak values (1.83 ± 0.22 m/s) at end‐inspiration, followed by softer values during forced abdominal pressure (1.60 ± 0.22 m/s) and end‐expiration (1.49 ± 0.22 m/s). The effects of inspiration and expiration were confirmed by time‐harmonic elastography.Conclusion: Our results suggest that subsecond MRE of the liver is useful for checking MRE driver settings and monitoring breathing‐induced changes in liver stiffness in near real time.