Ming-Xin Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ming-Xin Lee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chin-Yu Lin
China Medical University
2 shared publications - Fu-Jen Kao
Institute of Biophotonics, National Yang-Ming University, 155, Sec 2, Linong Street, Taipei, Taipei City, 11221, TAIWAN
2 shared publications - Guan-Yu Zhuo
Institute of Biophotonics, College of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
2 shared publications - Wei-Hsun Wang
Institute of Translational Medicine and New Drug Development, China Medical University 2 , Taichung 404328, Taiwan
2 shared publications - Wei-Liang Chen
Center for Condensed Matter Sciences, National Taiwan University 3 , Taipei 10617, Taiwan
2 shared publications Chun-Yu Chou
Karlsruhe Institute of Technology (KIT)-Optics & Photonics 3 , Kaiserstraße 12 76131 Karlsruhe, Germany
1 shared publication
Latest Publications
- Open Access
- 30 April 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026107
Investigating cartilage-related diseases by polarization-resolved second harmonic generation (P-SHG) imaging
Establishing quantitative parameters for differentiating between healthy and diseased cartilage tissues by examining collagen fibril degradation patterns facilitates the understanding of tissue characteristics during disease progression. These findings could also complement existing clinical methods used to diagnose cartilage-related diseases. In this study, cartilage samples from normal, osteoarthritis (OA), and rheumatoid arthritis (RA) tissues were prepared and analyzed using polarization-resolved second harmonic generation (P-SHG) imaging and quantitative image texture analysis. The enhanced molecular contrast obtained from this approach is expected to aid in distinguishing between healthy and diseased cartilage tissues. P-SHG image analysis revealed distinct parameters in the cartilage samples, reflecting variations in collagen fibril arrangement and organization across different pathological states. Normal tissues exhibited distinct χ33/χ31 values compared with those of OA and RA, indicating collagen type transition and cartilage erosion with chondrocyte swelling, respectively. Compared with those of normal tissues, OA samples demonstrated a higher degree of linear polarization, suggesting increased tissue birefringence due to the deposition of type-I collagen in the extracellular matrix. The distribution of the planar orientation of collagen fibrils revealed a more directional orientation in the OA samples, associated with increased type-I collagen, while the RA samples exhibited a heterogeneous molecular orientation. This study revealed that the imaging technique, the quantitative analysis of the images, and the derived parameters presented in this study could be used as a reference for disease diagnostics, providing a clear understanding of collagen fibril degradation in cartilage.
- 30 April 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026107
Open AccessInvestigating cartilage-related diseases by polarization-resolved second harmonic generation (P-SHG) imaging
Establishing quantitative parameters for differentiating between healthy and diseased cartilage tissues by examining collagen fibril degradation patterns facilitates the understanding of tissue characteristics during disease progression. These findings could also complement existing clinical methods used to diagnose cartilage-related diseases. In this study, cartilage samples from normal, osteoarthritis (OA), and rheumatoid arthritis (RA) tissues were prepared and analyzed using polarization-resolved second harmonic generation (P-SHG) imaging and quantitative image texture analysis. The enhanced molecular contrast obtained from this approach is expected to aid in distinguishing between healthy and diseased cartilage tissues. P-SHG image analysis revealed distinct parameters in the cartilage samples, reflecting variations in collagen fibril arrangement and organization across different pathological states. Normal tissues exhibited distinct χ33/χ31 values compared with those of OA and RA, indicating collagen type transition and cartilage erosion with chondrocyte swelling, respectively. Compared with those of normal tissues, OA samples demonstrated a higher degree of linear polarization, suggesting increased tissue birefringence due to the deposition of type-I collagen in the extracellular matrix. The distribution of the planar orientation of collagen fibrils revealed a more directional orientation in the OA samples, associated with increased type-I collagen, while the RA samples exhibited a heterogeneous molecular orientation. This study revealed that the imaging technique, the quantitative analysis of the images, and the derived parameters presented in this study could be used as a reference for disease diagnostics, providing a clear understanding of collagen fibril degradation in cartilage.
- 25 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (13)
Calibrated χ(2)-tensor polarization-resolved second harmonic generation microscopy for precise tissue imaging
Polarization-resolved second harmonic generation (P-SHG) microscopy is commonly used to analyze the second-order susceptibility, χ(2), tensor, which enables the calculation of the molecular structure of harmonophores. However, despite extensive research on type I collagen, the measured χ(2) ratios vary considerably among published values, which raises the question of whether P-SHG imaging is universally applicable to all tissues containing harmonophores. In this work, we propose that the deviation of χ(2) ratios is primarily due to ignoring the molecular tilt angle and chirality in image analysis. To confirm our hypothesis, we present an analytical model based on C6 symmetry that takes into account these two factors. We also introduce an imaging scheme that splits SHG into X- and Y-polarized image components for χ(2) tensor analysis. Our approach effectively improves the precision of determining χ(2) ratios, depending on how much the two factors affect the P-SHG signals.
- 25 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (13)
Calibrated χ(2)-tensor polarization-resolved second harmonic generation microscopy for precise tissue imaging
Polarization-resolved second harmonic generation (P-SHG) microscopy is commonly used to analyze the second-order susceptibility, χ(2), tensor, which enables the calculation of the molecular structure of harmonophores. However, despite extensive research on type I collagen, the measured χ(2) ratios vary considerably among published values, which raises the question of whether P-SHG imaging is universally applicable to all tissues containing harmonophores. In this work, we propose that the deviation of χ(2) ratios is primarily due to ignoring the molecular tilt angle and chirality in image analysis. To confirm our hypothesis, we present an analytical model based on C6 symmetry that takes into account these two factors. We also introduce an imaging scheme that splits SHG into X- and Y-polarized image components for χ(2) tensor analysis. Our approach effectively improves the precision of determining χ(2) ratios, depending on how much the two factors affect the P-SHG signals.