Min Suk Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Min Suk Lee has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Gert Cauwenberghs
University of California, San Diego
4 shared publications - Akshay Paul
Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
3 shared publications - Patrick P. Mercier
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
3 shared publications - Yuchen Xu
Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
3 shared publications - Abhinav Uppal
University of California, San Diego
2 shared publications Brian L. Wuerstle
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (5) , 1-9
Multiplexed Crossbar GFET Array With BioADC for Multi-Modal Aptamer-Based Sensing
We aimed to develop a scalable, low-power graphene field-effect transistor (GFET) crossbar array integrated with a neural-interface system-on-chip (NISoC), termed the GFET-NISoC platform, for multiplexed, real-time biomolecular sensing, including ultra-sensitive detection of Pb2+ using a G-quadruplex ssDNA aptamer. A 12×12 GFET crossbar array was fabricated using a multilayer dielectric stack and optimized graphene transfer. Characterization was performed using both benchtop instrumentation and a low-power NISoC front-end supporting current- and voltage-clamp modes. Ionic strength, pH, and Pb2+ dose-response measurements were obtained from functionalized arrays. The platform demonstrated uniform Dirac behavior, reversible pH-dependent conductance, predictable ionic-strength responses, and femtomolar-level Pb2+ detection with strong selectivity over Ca2+ and Co2+. The GFET-NISoC system enables multiplexed, multi-modal sensing at sub-μW power levels and provides a promising foundation for wearable or point-of-care chemical and biomolecular monitoring.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (5) , 1-9
Multiplexed Crossbar GFET Array With BioADC for Multi-Modal Aptamer-Based Sensing
We aimed to develop a scalable, low-power graphene field-effect transistor (GFET) crossbar array integrated with a neural-interface system-on-chip (NISoC), termed the GFET-NISoC platform, for multiplexed, real-time biomolecular sensing, including ultra-sensitive detection of Pb2+ using a G-quadruplex ssDNA aptamer. A 12×12 GFET crossbar array was fabricated using a multilayer dielectric stack and optimized graphene transfer. Characterization was performed using both benchtop instrumentation and a low-power NISoC front-end supporting current- and voltage-clamp modes. Ionic strength, pH, and Pb2+ dose-response measurements were obtained from functionalized arrays. The platform demonstrated uniform Dirac behavior, reversible pH-dependent conductance, predictable ionic-strength responses, and femtomolar-level Pb2+ detection with strong selectivity over Ca2+ and Co2+. The GFET-NISoC system enables multiplexed, multi-modal sensing at sub-μW power levels and provides a promising foundation for wearable or point-of-care chemical and biomolecular monitoring.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 18 (19373333) , 5-25
Earable Multimodal Sensing and Stimulation: A Prospective Toward Unobtrusive Closed-Loop Biofeedback
The human ear has emerged as a bidirectional gateway to the brain's and body's signals. Recent advances in around-the-ear and in-ear sensors have enabled the assessment of biomarkers and physiomarkers derived from brain and cardiac activity using ear-electroencephalography (ear-EEG), photoplethysmography (ear-PPG), and chemical sensing of analytes from the ear, with ear-EEG having been taken beyond-the-lab to outer space. Parallel advances in non-invasive and minimally invasive brain stimulation techniques have leveraged the ear's access to two cranial nerves to modulate brain and body activity. The vestibulocochlear nerve stimulates the auditory cortex and limbic system with sound, while the auricular branch of the vagus nerve indirectly but significantly couples to the autonomic nervous system and cardiac output. Acoustic and current mode stimuli delivered using discreet and unobtrusive earables are an active area of research, aiming to make biofeedback and bioelectronic medicine deliverable outside of the clinic, with remote and continuous monitoring of therapeutic responsivity and long-term adaptation. Leveraging recent advances in ear-EEG, transcutaneous auricular vagus nerve stimulation (taVNS), and unobtrusive acoustic stimulation, we review accumulating evidence that combines their potential into an integrated earable platform for closed-loop multimodal sensing and neuromodulation, towards personalized and holistic therapies that are near, in- and around-the-ear.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 18 (19373333) , 5-25
Earable Multimodal Sensing and Stimulation: A Prospective Toward Unobtrusive Closed-Loop Biofeedback
The human ear has emerged as a bidirectional gateway to the brain's and body's signals. Recent advances in around-the-ear and in-ear sensors have enabled the assessment of biomarkers and physiomarkers derived from brain and cardiac activity using ear-electroencephalography (ear-EEG), photoplethysmography (ear-PPG), and chemical sensing of analytes from the ear, with ear-EEG having been taken beyond-the-lab to outer space. Parallel advances in non-invasive and minimally invasive brain stimulation techniques have leveraged the ear's access to two cranial nerves to modulate brain and body activity. The vestibulocochlear nerve stimulates the auditory cortex and limbic system with sound, while the auricular branch of the vagus nerve indirectly but significantly couples to the autonomic nervous system and cardiac output. Acoustic and current mode stimuli delivered using discreet and unobtrusive earables are an active area of research, aiming to make biofeedback and bioelectronic medicine deliverable outside of the clinic, with remote and continuous monitoring of therapeutic responsivity and long-term adaptation. Leveraging recent advances in ear-EEG, transcutaneous auricular vagus nerve stimulation (taVNS), and unobtrusive acoustic stimulation, we review accumulating evidence that combines their potential into an integrated earable platform for closed-loop multimodal sensing and neuromodulation, towards personalized and holistic therapies that are near, in- and around-the-ear.
- 26 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (2) , 263-273
A Low-Noise Low-Power 0.001Hz–1kHz Neural Recording System-on-Chip With Sample-Level Duty-Cycling
Advances in brain-machine interfaces and wearable biomedical sensors for healthcare and human-computer interactions call for precision electrophysiology to resolve a variety of biopotential signals across the body that cover a wide range of frequencies, from the mHz-range electrogastrogram (EGG) to the kHz-range electroneurogram (ENG). Existing integrated wearable solutions for minimally invasive biopotential recordings are limited in detection range and accuracy due to trade-offs in bandwidth, noise, input impedance, and power consumption. This article presents a 16-channel wide-band ultra-low-noise neural recording system-on-chip (SoC) fabricated in 65nm CMOS for chronic use in mobile healthcare settings that spans a bandwidth of 0.001 Hz to 1 kHz through a featured sample-level duty-cycling (SLDC) mode. Each recording channel is implemented by a delta-sigma analog-to-digital converter (ADC) achieving 1.0 μ V rms input-referred noise over 1Hz–1kHz bandwidth with a Noise Efficiency Factor (NEF) of 2.93 in continuous operation mode. In SLDC mode, the power supply is duty-cycled while maintaining consistently low input-referred noise levels at ultra-low frequencies (1.1 μ V rms over 0.001Hz–1Hz) and 435 MΩ input impedance. The functionalities of the proposed SoC are validated with two human electrophysiology applications: recording low-amplitude electroencephalogram (EEG) through electrodes fixated on the forehead to monitor brain waves, and ultra-slow-wave electrogastrogram (EGG) through electrodes fixated on the abdomen to monitor digestion.
- 26 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (2) , 263-273
A Low-Noise Low-Power 0.001Hz–1kHz Neural Recording System-on-Chip With Sample-Level Duty-Cycling
Advances in brain-machine interfaces and wearable biomedical sensors for healthcare and human-computer interactions call for precision electrophysiology to resolve a variety of biopotential signals across the body that cover a wide range of frequencies, from the mHz-range electrogastrogram (EGG) to the kHz-range electroneurogram (ENG). Existing integrated wearable solutions for minimally invasive biopotential recordings are limited in detection range and accuracy due to trade-offs in bandwidth, noise, input impedance, and power consumption. This article presents a 16-channel wide-band ultra-low-noise neural recording system-on-chip (SoC) fabricated in 65nm CMOS for chronic use in mobile healthcare settings that spans a bandwidth of 0.001 Hz to 1 kHz through a featured sample-level duty-cycling (SLDC) mode. Each recording channel is implemented by a delta-sigma analog-to-digital converter (ADC) achieving 1.0 μ V rms input-referred noise over 1Hz–1kHz bandwidth with a Noise Efficiency Factor (NEF) of 2.93 in continuous operation mode. In SLDC mode, the power supply is duty-cycled while maintaining consistently low input-referred noise levels at ultra-low frequencies (1.1 μ V rms over 0.001Hz–1Hz) and 435 MΩ input impedance. The functionalities of the proposed SoC are validated with two human electrophysiology applications: recording low-amplitude electroencephalogram (EEG) through electrodes fixated on the forehead to monitor brain waves, and ultra-slow-wave electrogastrogram (EGG) through electrodes fixated on the abdomen to monitor digestion.
- Top Cited PapersOpen Access
- 28 September 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1307-1320
In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.
- 28 September 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1307-1320
Top Cited PapersOpen AccessIn-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.