Abhinav Uppal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abhinav Uppal has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Brian L. Wuerstle
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications- Gert Cauwenberghs
University of California, San Diego
2 shared publications Kuldeep Mahato
Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications- Min Suk Lee
University of California San Diego, San Diego, CA, USA
2 shared publications - Muyang Lin
Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications - Patrick P. Mercier
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications
Latest Publications
- Open Access
- 10 September 2026
- Published by Springer Nature in Research Square
Analog Neuromorphic Systems for Implantable Neural Interfaces
With the increasing popularity of brain-machine interfaces for a variety of motor disorders and fundamental neuroscientific experiments, there is also a growth in new sensors with increasing number of parallel channels to sense brain activity. Hence, there is an urgent need to manage the exploding datarate and power dissipation of these devices. Analog neuromorphic computing promises to be a natural candidate for bringing intelligence to implantable neural interfaces, thus only needing to transmit sparse information gleaned from the raw neural recordings. Neuromorphic event-driven sampling can reduce datarate at the source producing spikes that can natively be processed by low-power, sparsely activated spiking neural networks (SNN), that detect events of interest such as epileptic seizures or occurrence of biological action potentials (AP). This work compares popular neuromorphic analog-spike converters (ASC) in terms of their robustness to interference and shows delta modulation to be superior to integrate and fire modes of spike generation. Further, a new type of delta modulation inspired by high threshold bursting neurons in the hippocampus is shown to extend the tradeoff between compression ratio and data fidelity for conventional delta modulation. Measured results from fabricated integrated circuits show excellent data compression rates far exceeding those of conventional analog digital converter with Nyquist sampling. Further, mixed-signal, clockless SNNs interfaced with this bursting ASC are shown to be able to classify the generated spikes to detect AP events with high accuracy while dissipating scant energy.
- 10 September 2026
- Published by Springer Nature in Research Square
Open AccessAnalog Neuromorphic Systems for Implantable Neural Interfaces
With the increasing popularity of brain-machine interfaces for a variety of motor disorders and fundamental neuroscientific experiments, there is also a growth in new sensors with increasing number of parallel channels to sense brain activity. Hence, there is an urgent need to manage the exploding datarate and power dissipation of these devices. Analog neuromorphic computing promises to be a natural candidate for bringing intelligence to implantable neural interfaces, thus only needing to transmit sparse information gleaned from the raw neural recordings. Neuromorphic event-driven sampling can reduce datarate at the source producing spikes that can natively be processed by low-power, sparsely activated spiking neural networks (SNN), that detect events of interest such as epileptic seizures or occurrence of biological action potentials (AP). This work compares popular neuromorphic analog-spike converters (ASC) in terms of their robustness to interference and shows delta modulation to be superior to integrate and fire modes of spike generation. Further, a new type of delta modulation inspired by high threshold bursting neurons in the hippocampus is shown to extend the tradeoff between compression ratio and data fidelity for conventional delta modulation. Measured results from fabricated integrated circuits show excellent data compression rates far exceeding those of conventional analog digital converter with Nyquist sampling. Further, mixed-signal, clockless SNNs interfaced with this bursting ASC are shown to be able to classify the generated spikes to detect AP events with high accuracy while dissipating scant energy.
- Open Access
- 1 November 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (5) , 3929-3935
An efficient continuous-tone procedure for the study of frequency discrimination
This paper describes a method of gathering experimental data for the study of frequency discrimination. The method is efficient in terms of participant time, is easy to deploy on an online platform to gather behavioral responses, and allows simultaneous measurement of brain activity without contamination from onset responses. The participant hears a continuous tone within each block, with frequency steps at predetermined intervals, and is invited to respond “up” or “down” to these steps by pressing one of two keys. The magnitude of the steps varies according to a predetermined schedule (constant-stimuli, not adaptive) from large (easy) to small (hard), and the discrimination threshold is derived from a psychometric function fitted to the responses to this sequence. Comparison with earlier published procedures shows that the new method yields comparable thresholds, albeit less variable and slightly lower, and thus presumably closer to sensory limits.
- 1 November 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (5) , 3929-3935
Open AccessAn efficient continuous-tone procedure for the study of frequency discrimination
This paper describes a method of gathering experimental data for the study of frequency discrimination. The method is efficient in terms of participant time, is easy to deploy on an online platform to gather behavioral responses, and allows simultaneous measurement of brain activity without contamination from onset responses. The participant hears a continuous tone within each block, with frequency steps at predetermined intervals, and is invited to respond “up” or “down” to these steps by pressing one of two keys. The magnitude of the steps varies according to a predetermined schedule (constant-stimuli, not adaptive) from large (easy) to small (hard), and the discrimination threshold is derived from a psychometric function fitted to the responses to this sequence. Comparison with earlier published procedures shows that the new method yields comparable thresholds, albeit less variable and slightly lower, and thus presumably closer to sensory limits.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 18 (19373333) , 5-25
Earable Multimodal Sensing and Stimulation: A Prospective Toward Unobtrusive Closed-Loop Biofeedback
The human ear has emerged as a bidirectional gateway to the brain's and body's signals. Recent advances in around-the-ear and in-ear sensors have enabled the assessment of biomarkers and physiomarkers derived from brain and cardiac activity using ear-electroencephalography (ear-EEG), photoplethysmography (ear-PPG), and chemical sensing of analytes from the ear, with ear-EEG having been taken beyond-the-lab to outer space. Parallel advances in non-invasive and minimally invasive brain stimulation techniques have leveraged the ear's access to two cranial nerves to modulate brain and body activity. The vestibulocochlear nerve stimulates the auditory cortex and limbic system with sound, while the auricular branch of the vagus nerve indirectly but significantly couples to the autonomic nervous system and cardiac output. Acoustic and current mode stimuli delivered using discreet and unobtrusive earables are an active area of research, aiming to make biofeedback and bioelectronic medicine deliverable outside of the clinic, with remote and continuous monitoring of therapeutic responsivity and long-term adaptation. Leveraging recent advances in ear-EEG, transcutaneous auricular vagus nerve stimulation (taVNS), and unobtrusive acoustic stimulation, we review accumulating evidence that combines their potential into an integrated earable platform for closed-loop multimodal sensing and neuromodulation, towards personalized and holistic therapies that are near, in- and around-the-ear.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 18 (19373333) , 5-25
Earable Multimodal Sensing and Stimulation: A Prospective Toward Unobtrusive Closed-Loop Biofeedback
The human ear has emerged as a bidirectional gateway to the brain's and body's signals. Recent advances in around-the-ear and in-ear sensors have enabled the assessment of biomarkers and physiomarkers derived from brain and cardiac activity using ear-electroencephalography (ear-EEG), photoplethysmography (ear-PPG), and chemical sensing of analytes from the ear, with ear-EEG having been taken beyond-the-lab to outer space. Parallel advances in non-invasive and minimally invasive brain stimulation techniques have leveraged the ear's access to two cranial nerves to modulate brain and body activity. The vestibulocochlear nerve stimulates the auditory cortex and limbic system with sound, while the auricular branch of the vagus nerve indirectly but significantly couples to the autonomic nervous system and cardiac output. Acoustic and current mode stimuli delivered using discreet and unobtrusive earables are an active area of research, aiming to make biofeedback and bioelectronic medicine deliverable outside of the clinic, with remote and continuous monitoring of therapeutic responsivity and long-term adaptation. Leveraging recent advances in ear-EEG, transcutaneous auricular vagus nerve stimulation (taVNS), and unobtrusive acoustic stimulation, we review accumulating evidence that combines their potential into an integrated earable platform for closed-loop multimodal sensing and neuromodulation, towards personalized and holistic therapies that are near, in- and around-the-ear.
- Top Cited PapersOpen Access
- 28 September 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1307-1320
In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.
- 28 September 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1307-1320
Top Cited PapersOpen AccessIn-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.