Mohd Luqman Mohd Jamil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohd Luqman Mohd Jamil has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Saifuzam Jamri
Universiti Teknikal Malaysia Melaka
2 shared publications - Muhammad Nizam Kamarudin
Universiti Teknikal Malaysia Melaka
2 shared publications - Auzani Jidin
Universiti Teknikal Malaysia Melaka
1 shared publication - How Xuan Yu
Universiti Teknikal Malaysia Melaka
1 shared publication - Jenn Hwai Leong
Universiti Malaysia Perlis
1 shared publication Kwang T. C.
Universiti Teknikal Malaysia Melaka
1 shared publication
Latest Publications
- Open Access
- 1 December 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (4) , 2474-2485
Transient finite-element co-optimization of an asymmetric stator slot-pitch three-phase 12/10 SRM for electric vehicle powertrains
Switched reluctance motors (SRMs) provide a robust, rare-earth-free traction option for electric vehicles, but standard 12/10 configurations suffer from high core losses, direct three-phase incompatibility, and power converter complexity. To overcome these issues, this study proposes an asymmetric three-phase 12/10 SRM featuring alternating 36°/24° stator pole pitches to enable localized short flux paths using a standard 3-phase inverter. Machine dimensions were analytically sized for a 48 V, 471 W drive operating at 3000 rpm using M250-35A electrical steel. A 2D transient finite-element framework co-optimized pole arcs, coil turns, and dynamic switching angles. Electromagnetic performance was systematically benchmarked against conventional 6/4, 12/8, 18/12, and standard six-phase 12/10 topologies. The optimized 12/10 SRM delivers 1.57 Nm rated torque while suppressing torque ripple to 24.7%, outperforming the 6/4 (103.3%) and 6-phase 12/10 (26.1%) baselines. Shortened localized flux paths reduce core losses to 6.5 W, an 80% reduction compared to previous baselines, yielding 91.8% efficiency and 0.072 Nm/A torque-per-ampere at 21.4 A phase RMS current. This configuration halves the required power switches and mitigates driveline vibration, delivering a cost-effective, mechanically robust traction solution for electric vehicles.
- 1 December 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (4) , 2474-2485
Open AccessTransient finite-element co-optimization of an asymmetric stator slot-pitch three-phase 12/10 SRM for electric vehicle powertrains
Switched reluctance motors (SRMs) provide a robust, rare-earth-free traction option for electric vehicles, but standard 12/10 configurations suffer from high core losses, direct three-phase incompatibility, and power converter complexity. To overcome these issues, this study proposes an asymmetric three-phase 12/10 SRM featuring alternating 36°/24° stator pole pitches to enable localized short flux paths using a standard 3-phase inverter. Machine dimensions were analytically sized for a 48 V, 471 W drive operating at 3000 rpm using M250-35A electrical steel. A 2D transient finite-element framework co-optimized pole arcs, coil turns, and dynamic switching angles. Electromagnetic performance was systematically benchmarked against conventional 6/4, 12/8, 18/12, and standard six-phase 12/10 topologies. The optimized 12/10 SRM delivers 1.57 Nm rated torque while suppressing torque ripple to 24.7%, outperforming the 6/4 (103.3%) and 6-phase 12/10 (26.1%) baselines. Shortened localized flux paths reduce core losses to 6.5 W, an 80% reduction compared to previous baselines, yielding 91.8% efficiency and 0.072 Nm/A torque-per-ampere at 21.4 A phase RMS current. This configuration halves the required power switches and mitigates driveline vibration, delivering a cost-effective, mechanically robust traction solution for electric vehicles.
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (4) , 2296-2306
Design and analysis of brushless permanent magnet motor for light electrically powered two-wheeler vehicle
This study provides a comprehensive process of designing an electric motor that will be used for a small two-wheeled electric vehicle. Due to high performance capability in term of power and torque, brushless permanent magnet topology is chosen so that a compromise between size constraint and performance can be met. For an accurate motor design sizing, the design process is initially carried out by determination of power rating that derived from vehicle dynamic calculation. Based on winding factor calculation, fractional-slot 12-slot/10-pole and 9-slot/10-pole motors equipped with non-overlapping winding are chosen and analyzed using finite element analysis (FEA) software. For an optimum electromagnetic performance, parametric optimization is included, mainly on the stator dimension. Despite the performance of both designs improved, only 9-slot motor results a convincing performance as the rated torque is 18% higher than the 12-slot design. For verification purpose, 1-D analytical solution is also included and compared with results deduced by the FEA. According to the analysis, the proposed motor designs are adequately reliable for a light electrically powered electric vehicle application.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (4) , 2296-2306
Open AccessDesign and analysis of brushless permanent magnet motor for light electrically powered two-wheeler vehicle
This study provides a comprehensive process of designing an electric motor that will be used for a small two-wheeled electric vehicle. Due to high performance capability in term of power and torque, brushless permanent magnet topology is chosen so that a compromise between size constraint and performance can be met. For an accurate motor design sizing, the design process is initially carried out by determination of power rating that derived from vehicle dynamic calculation. Based on winding factor calculation, fractional-slot 12-slot/10-pole and 9-slot/10-pole motors equipped with non-overlapping winding are chosen and analyzed using finite element analysis (FEA) software. For an optimum electromagnetic performance, parametric optimization is included, mainly on the stator dimension. Despite the performance of both designs improved, only 9-slot motor results a convincing performance as the rated torque is 18% higher than the 12-slot design. For verification purpose, 1-D analytical solution is also included and compared with results deduced by the FEA. According to the analysis, the proposed motor designs are adequately reliable for a light electrically powered electric vehicle application.
- Open Access
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 3153-3160
Total power deficit estimation for isolated power system network using H∞ norm method
An isolated electrical network with an independent local distributed generator is very sensitive towards the contingencies between load demand and supply. Although the network system has less complexity in term of structure, its stability condition is crucial due to its stand-alone operating condition. Hence, to monitor the stability of the network, total power deficit is the only variable that can be estimated. This study proposed to utilize the filtering problem to design an estimator that can estimate the total power deficiency. For verification, the design estimator was tested under two cases which are nominal case and parameter uncertainty case. In nominal case, the system parameters are assumed to be known while in parameter uncertainty case the system has contaminated with uncertain parameter where its admissible value is laying in a given polytope. With complying the linear matrix inequality (LMI) constraint, the main objective function of the norm was guaranteed with minimum upper bound. The results show that the dynamical behaviors of designed estimator successfully trace the actual power deficit signal at steady state with minimal estimation error.
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 3153-3160
Open AccessTotal power deficit estimation for isolated power system network using H∞ norm method
An isolated electrical network with an independent local distributed generator is very sensitive towards the contingencies between load demand and supply. Although the network system has less complexity in term of structure, its stability condition is crucial due to its stand-alone operating condition. Hence, to monitor the stability of the network, total power deficit is the only variable that can be estimated. This study proposed to utilize the filtering problem to design an estimator that can estimate the total power deficiency. For verification, the design estimator was tested under two cases which are nominal case and parameter uncertainty case. In nominal case, the system parameters are assumed to be known while in parameter uncertainty case the system has contaminated with uncertain parameter where its admissible value is laying in a given polytope. With complying the linear matrix inequality (LMI) constraint, the main objective function of the norm was guaranteed with minimum upper bound. The results show that the dynamical behaviors of designed estimator successfully trace the actual power deficit signal at steady state with minimal estimation error.
- Open Access
- 1 September 2021
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 23 (3) , 1249-1257
Total power deficiency estimation of isolated power system network using full-state observer method
An isolated electrical network with an independent local distributed generator is very sensitive towards the contingencies between load demand and supply. Although the network system has less complexity in term of structure, its stability condition is crucial due to its stand-alone operating condition. The total power deficit in the network gives the important information related to the dynamical frequency responses which may directly affect the system’s stability level. In this paper, the approach to estimate the total power deficiency for the isolated electrical network was presented by utilized the Luenberger observer method. Although the power deficit is not the state variable in the network mathematical model, the solution of estimation problem was feasible by introducing the new variable using additional dummy system. The simulation was carried out by using MATLAB/Simulink environment and the designed estimator was verified using multifarious load demand changes. The results show that the estimated signal was successfully tracked the expected actual signal with minimum error.
- 1 September 2021
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 23 (3) , 1249-1257
Open AccessTotal power deficiency estimation of isolated power system network using full-state observer method
An isolated electrical network with an independent local distributed generator is very sensitive towards the contingencies between load demand and supply. Although the network system has less complexity in term of structure, its stability condition is crucial due to its stand-alone operating condition. The total power deficit in the network gives the important information related to the dynamical frequency responses which may directly affect the system’s stability level. In this paper, the approach to estimate the total power deficiency for the isolated electrical network was presented by utilized the Luenberger observer method. Although the power deficit is not the state variable in the network mathematical model, the solution of estimation problem was feasible by introducing the new variable using additional dummy system. The simulation was carried out by using MATLAB/Simulink environment and the designed estimator was verified using multifarious load demand changes. The results show that the estimated signal was successfully tracked the expected actual signal with minimum error.
- Open Access
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 10 (3) , 3323-3332
Improved magnetic behavior of hemicycle PM motor via stator modification
This article presents the simple basic sizing approaches to decrease overall weight of motor and improve magnetic characteristics in PM motor. A review on various stator design in PM motor i.e. radial-flux or axial-flux with slotted or non-slotted is presented. As magnetic and electric loading influence the electromagnetic motor performance, modification on stator body are included in investigation for a desired electromagnetic torque performance. Influences of tooth body width sizing and additional stator slots sizing in PM motor equip with hemicycle stator design are carried out. Two designs are included, both having similar semi-circle stator but different in additional slot tooth within and over 180 ○ i.e. Design 2 and 3 respectively. For optimization using 2D-Finite Element Analysis, optimal tooth body sizing and additional stator tooth result the weight significantly reduce by 44%, 5.9 Nm output torque and 30% torque ripple.
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 10 (3) , 3323-3332
Open AccessImproved magnetic behavior of hemicycle PM motor via stator modification
This article presents the simple basic sizing approaches to decrease overall weight of motor and improve magnetic characteristics in PM motor. A review on various stator design in PM motor i.e. radial-flux or axial-flux with slotted or non-slotted is presented. As magnetic and electric loading influence the electromagnetic motor performance, modification on stator body are included in investigation for a desired electromagnetic torque performance. Influences of tooth body width sizing and additional stator slots sizing in PM motor equip with hemicycle stator design are carried out. Two designs are included, both having similar semi-circle stator but different in additional slot tooth within and over 180 ○ i.e. Design 2 and 3 respectively. For optimization using 2D-Finite Element Analysis, optimal tooth body sizing and additional stator tooth result the weight significantly reduce by 44%, 5.9 Nm output torque and 30% torque ripple.