HGHamid Ghanbari

Hamid Ghanbari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hamid Ghanbari has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    What is innovation?

    by Hamid Ghanbari


  • Open Access

    Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis

    by Sanidhya Singh, Miles Romney Bennett, Chen Chen, Sooyoon Shin, Hamid Ghanbari, Benjamin W Nelson

    Background: Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. Objective: This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. Methods: We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. Results: For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. Conclusions: SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.


  • Open Access

    Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis (Preprint)

    by Sanidhya Singh, Miles Romney Bennett, Chen Chen, Sooyoon Shin, Hamid Ghanbari, Benjamin W Nelson

    BACKGROUND Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. OBJECTIVE This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. METHODS We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. RESULTS For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. CONCLUSIONS SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.

  • Promises and Perils of Consumer Mobile Technologies in Cardiovascular Care

    by Niraj Varma, Janet K. Han, Rod Passman, Lindsey Anne Rosman, Hamid Ghanbari, Peter Noseworthy, Jennifer N. Avari Silva, Abhishek Deshmukh, Prashanthan Sanders, Gerhard Hindricks, et al.


  • Open Access

    Validation of a Deep Learning Algorithm for Continuous, Real‐Time Detection of Atrial Fibrillation Using a Wrist‐Worn Device in an Ambulatory Environment

    by Ming‐Zher Poh, Anthony J. Battisti, Li‐Fang Cheng, Janice Lin, Anil Patwardhan, Ganesh S. Venkataraman, Charles A. Athill, Nimesh S. Patel, Chinmay P. Patel, Christian E. Machado, et al.

    Background: Wearable devices may be useful for identification, quantification and characterization, and management of atrial fibrillation (AF). To date, consumer wrist‐worn devices for AF detection using photoplethysmography‐based algorithms perform only periodic checks when the user is stationary and are US Food and Drug Administration cleared for prediagnostic uses without intended use for clinical decision‐making. There is an unmet need for medical‐grade diagnostic wrist‐worn devices that provide long‐term, continuous AF monitoring. Methods and Results: We evaluated the performance of a wrist‐worn device with lead‐I ECG and continuous photoplethysmography (Verily Study Watch) and photoplethysmography‐based convolutional neural network for AF detection and burden estimation in a prospective multicenter study that enrolled 117 patients with paroxysmal AF. A 14‐day continuous ECG monitor (Zio XT) served as the reference device to evaluate algorithm sensitivity and specificity for detection of AF in 15‐minute intervals. A total of 91 857 intervals were contributed by 111 subjects with evaluable reference and test data (18.3 h/d median watch wear time). The watch was 96.1% sensitive (95% CI, 92.7%–98.0%) and 98.1% specific (95% CI, 97.2%–99.1%) for interval‐level AF detection. Photoplethysmography‐derived AF burden estimation was highly correlated with the reference device burden ( R 2 =0.986) with a mean difference of 0.8% (95% limits of agreement, −6.6% to 8.2%). Conclusions: Continuous monitoring using a photoplethysmography‐based convolutional neural network incorporated in a wrist‐worn device has clinical‐grade performance for AF detection and burden estimation. These findings suggest that monitoring can be performed with wrist‐worn wearables for diagnosis and clinical management of AF. Registration Information: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04546763.


  • Open Access

    Episodes of Atrial Fibrillation and Symptoms: A Temporal Analysis

    by Hamid Ghanbari, Daniel Whibley, H. Immo Lehmann, Zhi Li, Anna Kratz, Daniel J. Clauw, Brahmajee K. Nallamothu


  • Open Access

    Letter from the Deputy Editor

    by Hamid Ghanbari

  • Open Access

    Letter from the Deputy Editor

    by Hamid Ghanbari

  • Open Access

    Predicting atrial fibrillation episodes with rapid ventricular rates associated with low levels of activity

    by Zhi Li, Kevin M. Wheelock, Sangeeta Lathkar-Pradhan, Hakan Oral, Daniel J. Clauw, Pujitha Gunaratne, Jonathan Gryak, Kayvan Najarian, Brahmajee K. Nallamothu, Hamid Ghanbari

    Rapid and irregular ventricular rates (RVR) are an important consequence of atrial fibrillation (AF). Raw accelerometry data in combination with electrocardiogram (ECG) data have the potential to distinguish inappropriate from appropriate tachycardia in AF. This can allow for the development of a just-in-time intervention for clinical treatments of AF events. The objective of this study is to develop a machine learning algorithm that can distinguish episodes of AF with RVR that are associated with low levels of activity. This study involves 45 patients with persistent or paroxysmal AF. The ECG and accelerometer data were recorded continuously for up to 3 weeks. The prediction of AF episodes with RVR and low activity was achieved using a deterministic probabilistic finite-state automata (DPFA)-based approach. Rapid and irregular ventricular rate (RVR) is defined as having heart rates (HR) greater than 110 beats per minute (BPM) and high activity is defined as greater than 0.75 quantile of the activity level. The AF events were annotated using the FDA-cleared BeatLogic algorithm. Various time intervals prior to the events were used to determine the longest prediction intervals for predicting AF with RVR episodes associated with low levels of activity. Among the 961 annotated AF events, 292 met the criterion for RVR episode. There were 176 and 116 episodes with low and high activity levels respectively. Out of the 961 AF episodes, 770 (80.1%) were used in the training data set and the remaining 191 intervals were held out for testing. The model was able to predict AF with RVR and low activity up to 4.5 min before the events. The mean prediction performance gradually decreased as the time to events increased. The overall Area under the ROC Curve (AUC) for the model lies within the range of 0.67–0.78. The DPFA algorithm can predict AF with RVR associated with low levels of activity up to 4.5 min before the onset of the event. This would enable the development of just-in-time interventions that could reduce the morbidity and mortality associated with AF and other similar arrhythmias.


  • Open Access

    Letter from the Deputy Editor

    by Hamid Ghanbari