Linyang He
Linyang He has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chunyu Ma
Department of Radiology, Gansu Provincial Hospital, Lanzhou, China
2 shared publications - Fuwen Dong
Department of Radiology, Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou, China
2 shared publications - Guohua Cheng
Hangzhou Jianpei Technology Company Ltd., Hangzhou, China
2 shared publications - Hongyan Yao
Department of Radiology, Gansu Provincial Hospital, Lanzhou, China
2 shared publications - Sheng Zhou
Department of Radiology, Gansu Provincial Hospital, China
2 shared publications - Xiaofei Chen
Department of Radiology, Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou, China
2 shared publications
Latest Publications
- Open Access
- 28 March 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Multimedia Computing, Communications, and Applications
- Vol. 22 (8) , 1-19
SVGS: Single-View to 3D Object Editing via Gaussian Splatting
Text-driven 3D scene editing has attracted considerable interest due to its convenience and user-friendliness. However, methods that rely on implicit 3D representations, such as Neural Radiance Fields (NeRF), while effective in rendering complex scenes, are hindered by slow processing speeds and limited control over specific regions of the scene. Moreover, existing approaches, including Instruct-NeRF2NeRF and GaussianEditor, which utilize multi-view editing strategies, frequently produce inconsistent results across different views when executing text instructions. This inconsistency can adversely affect the overall performance of the model, complicating the task of balancing the consistency of editing results with editing efficiency. To address these challenges, we propose a novel method termed Single-View to 3D Object Editing via Gaussian Splatting (SVGS), which is a single-view text-driven editing technique based on 3D Gaussian Splatting (3DGS). Specifically, in response to text instructions, we introduce a single-view editing strategy grounded in multi-view diffusion models, which reconstructs 3D scenes by leveraging only those views that yield consistent editing results. Additionally, we employ sparse 3D Gaussian Splatting as the 3D representation, which significantly enhances editing efficiency. We conducted a comparative analysis of SVGS against existing baseline methods across various scene settings, and the results indicate that SVGS outperforms its counterparts in both editing capability and processing speed, representing a significant advancement in 3D editing technology. For further details, please visit our project page at: https://amateurc.github.io/svgs.github.io/ .
- 28 March 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Multimedia Computing, Communications, and Applications
- Vol. 22 (8) , 1-19
Open AccessSVGS: Single-View to 3D Object Editing via Gaussian Splatting
Text-driven 3D scene editing has attracted considerable interest due to its convenience and user-friendliness. However, methods that rely on implicit 3D representations, such as Neural Radiance Fields (NeRF), while effective in rendering complex scenes, are hindered by slow processing speeds and limited control over specific regions of the scene. Moreover, existing approaches, including Instruct-NeRF2NeRF and GaussianEditor, which utilize multi-view editing strategies, frequently produce inconsistent results across different views when executing text instructions. This inconsistency can adversely affect the overall performance of the model, complicating the task of balancing the consistency of editing results with editing efficiency. To address these challenges, we propose a novel method termed Single-View to 3D Object Editing via Gaussian Splatting (SVGS), which is a single-view text-driven editing technique based on 3D Gaussian Splatting (3DGS). Specifically, in response to text instructions, we introduce a single-view editing strategy grounded in multi-view diffusion models, which reconstructs 3D scenes by leveraging only those views that yield consistent editing results. Additionally, we employ sparse 3D Gaussian Splatting as the 3D representation, which significantly enhances editing efficiency. We conducted a comparative analysis of SVGS against existing baseline methods across various scene settings, and the results indicate that SVGS outperforms its counterparts in both editing capability and processing speed, representing a significant advancement in 3D editing technology. For further details, please visit our project page at: https://amateurc.github.io/svgs.github.io/ .
- Open Access
- 1 February 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1425-1438
Automatic measurement of X-ray radiographic parameters based on cascaded HRNet model from the supraspinatus outlet radiographs
Background: Rotator cuff injury is a common cause of shoulder pain. Precise and efficient measurement of morphological parameters is necessary in the clinical diagnosis and evaluation of shoulder disorders. However, manual measurement is a time-consuming and labor-intensive task, with low inter-observer reliability. The automatic measurement of radiographic parameters in supraspinatus outlet radiographs has not been reported yet. Thus, the objective of this study was to use a cascaded High-Resolution Net (HRNet) model based on deep learning (DL) algorithms to automatically measure morphological parameters from supraspinatus outlet radiographs and assess its performance. It was intended for use in early screening of patients with rotator cuff disease and to guide them to further consultation. Methods: This cross-sectional study collected 1,668 supraspinatus outlet radiographs from the picture archiving and communication system of Gansu Provincial Hospital of Traditional Chinese Medicine and the Affiliated Hospital of Gansu University of Chinese Medicine. Among them, 521 images were provided for test datasets and 1,147 images were provided for a model training dataset and validation dataset. Landmarks were annotated for acromio-humeral interval (AHI), acromial tilt (AT), and 3 lines in Park’s acromial classification (line huo-acrf, line acro-acro1, and line huo-acro1). R4 radiologist reviewed the means of 3 radiologists as a reference standard. Model performance was assessed by calculating the percentage of correct key points (PCK), intra-class correlation coefficients (ICCs), Pearson’s correlation coefficients, mean absolute error, and root mean square error. The reliability of R1, R2, R3, AI with R4 and inter-observer reliability of R1, R2, and R3 for acromial morphology classification were assessed by Cohen’s kappa coefficient. Results: Within the 3-mm threshold, the PCK of the model ranged from 74% to 100%. Compared to the reference standard, the model had reliable measurement of AHI, AT, line huo-acrf, line acro-acro1, line huo-acro1 (ICC =0.73–0.94) and moderate reliability of acromial morphology classification (k=0.50–0.56). Conclusions: The cascaded HRNet developed in this study can automatically measure morphological parameters of the shoulder. It may aid early clinical screening for shoulder disorders and assist physicians in treatment decisions.
- 1 February 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1425-1438
Open AccessAutomatic measurement of X-ray radiographic parameters based on cascaded HRNet model from the supraspinatus outlet radiographs
Background: Rotator cuff injury is a common cause of shoulder pain. Precise and efficient measurement of morphological parameters is necessary in the clinical diagnosis and evaluation of shoulder disorders. However, manual measurement is a time-consuming and labor-intensive task, with low inter-observer reliability. The automatic measurement of radiographic parameters in supraspinatus outlet radiographs has not been reported yet. Thus, the objective of this study was to use a cascaded High-Resolution Net (HRNet) model based on deep learning (DL) algorithms to automatically measure morphological parameters from supraspinatus outlet radiographs and assess its performance. It was intended for use in early screening of patients with rotator cuff disease and to guide them to further consultation. Methods: This cross-sectional study collected 1,668 supraspinatus outlet radiographs from the picture archiving and communication system of Gansu Provincial Hospital of Traditional Chinese Medicine and the Affiliated Hospital of Gansu University of Chinese Medicine. Among them, 521 images were provided for test datasets and 1,147 images were provided for a model training dataset and validation dataset. Landmarks were annotated for acromio-humeral interval (AHI), acromial tilt (AT), and 3 lines in Park’s acromial classification (line huo-acrf, line acro-acro1, and line huo-acro1). R4 radiologist reviewed the means of 3 radiologists as a reference standard. Model performance was assessed by calculating the percentage of correct key points (PCK), intra-class correlation coefficients (ICCs), Pearson’s correlation coefficients, mean absolute error, and root mean square error. The reliability of R1, R2, R3, AI with R4 and inter-observer reliability of R1, R2, and R3 for acromial morphology classification were assessed by Cohen’s kappa coefficient. Results: Within the 3-mm threshold, the PCK of the model ranged from 74% to 100%. Compared to the reference standard, the model had reliable measurement of AHI, AT, line huo-acrf, line acro-acro1, line huo-acro1 (ICC =0.73–0.94) and moderate reliability of acromial morphology classification (k=0.50–0.56). Conclusions: The cascaded HRNet developed in this study can automatically measure morphological parameters of the shoulder. It may aid early clinical screening for shoulder disorders and assist physicians in treatment decisions.
- 3 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 33 (11) , 4104-4118
Performance evaluation of a deep learning-based cascaded HRNet model for automatic measurement of X-ray imaging parameters of lumbar sagittal curvature
Purpose To develop a deep learning-based cascaded HRNet model, in order to automatically measure X-ray imaging parameters of lumbar sagittal curvature and to evaluate its prediction performance. Methods A total of 3730 lumbar lateral digital radiography (DR) images were collected from picture archiving and communication system (PACS). Among them, 3150 images were randomly selected as the training dataset and validation dataset, and 580 images as the test dataset. The landmarks of the lumbar curve index (LCI), lumbar lordosis angle (LLA), sacral slope (SS), lumbar lordosis index (LLI), and the posterior edge tangent angle of the vertebral body (PTA) were identified and marked. The measured results of landmarks on the test dataset were compared with the mean values of manual measurement as the reference standard. Percentage of correct key-points (PCK), intra-class correlation coefficient (ICC), Pearson correlation coefficient (r), mean absolute error (MAE), mean square error (MSE), root-mean-square error (RMSE), and Bland–Altman plot were used to evaluate the performance of the cascade HRNet model. Results The PCK of the cascaded HRNet model was 97.9–100% in the 3 mm distance threshold. The mean differences between the reference standard and the predicted values for LCI, LLA, SS, LLI, and PTA were 0.43 mm, 0.99°, 1.11°, 0.01 mm, and 0.23°, respectively. There were strong correlation and consistency of the five parameters between the cascaded HRNet model and manual measurements (ICC = 0.989–0.999, R = 0.991–0.999, MAE = 0.63–1.65, MSE = 0.61–4.06, RMSE = 0.78–2.01). Conclusion The cascaded HRNet model based on deep learning algorithm could accurately identify the sagittal curvature-related landmarks on lateral lumbar DR images and automatically measure the relevant parameters, which is of great significance in clinical application.
- 3 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 33 (11) , 4104-4118
Performance evaluation of a deep learning-based cascaded HRNet model for automatic measurement of X-ray imaging parameters of lumbar sagittal curvature
Purpose To develop a deep learning-based cascaded HRNet model, in order to automatically measure X-ray imaging parameters of lumbar sagittal curvature and to evaluate its prediction performance. Methods A total of 3730 lumbar lateral digital radiography (DR) images were collected from picture archiving and communication system (PACS). Among them, 3150 images were randomly selected as the training dataset and validation dataset, and 580 images as the test dataset. The landmarks of the lumbar curve index (LCI), lumbar lordosis angle (LLA), sacral slope (SS), lumbar lordosis index (LLI), and the posterior edge tangent angle of the vertebral body (PTA) were identified and marked. The measured results of landmarks on the test dataset were compared with the mean values of manual measurement as the reference standard. Percentage of correct key-points (PCK), intra-class correlation coefficient (ICC), Pearson correlation coefficient (r), mean absolute error (MAE), mean square error (MSE), root-mean-square error (RMSE), and Bland–Altman plot were used to evaluate the performance of the cascade HRNet model. Results The PCK of the cascaded HRNet model was 97.9–100% in the 3 mm distance threshold. The mean differences between the reference standard and the predicted values for LCI, LLA, SS, LLI, and PTA were 0.43 mm, 0.99°, 1.11°, 0.01 mm, and 0.23°, respectively. There were strong correlation and consistency of the five parameters between the cascaded HRNet model and manual measurements (ICC = 0.989–0.999, R = 0.991–0.999, MAE = 0.63–1.65, MSE = 0.61–4.06, RMSE = 0.78–2.01). Conclusion The cascaded HRNet model based on deep learning algorithm could accurately identify the sagittal curvature-related landmarks on lateral lumbar DR images and automatically measure the relevant parameters, which is of great significance in clinical application.