GCGuohua Cheng

Guohua Cheng

*This is an algorithmically generated author record based on publicly available information.

Guohua Cheng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic measurement of X-ray radiographic parameters based on cascaded HRNet model from the supraspinatus outlet radiographs

    by Yuwen Zheng, Yuhua Wu, Xiaofei Chen, Ping Wang, Fuwen Dong, Linyang He, Qing Su, Guohua Cheng, Chunyu Ma, Hongyan Yao, et al.

    Background: Rotator cuff injury is a common cause of shoulder pain. Precise and efficient measurement of morphological parameters is necessary in the clinical diagnosis and evaluation of shoulder disorders. However, manual measurement is a time-consuming and labor-intensive task, with low inter-observer reliability. The automatic measurement of radiographic parameters in supraspinatus outlet radiographs has not been reported yet. Thus, the objective of this study was to use a cascaded High-Resolution Net (HRNet) model based on deep learning (DL) algorithms to automatically measure morphological parameters from supraspinatus outlet radiographs and assess its performance. It was intended for use in early screening of patients with rotator cuff disease and to guide them to further consultation. Methods: This cross-sectional study collected 1,668 supraspinatus outlet radiographs from the picture archiving and communication system of Gansu Provincial Hospital of Traditional Chinese Medicine and the Affiliated Hospital of Gansu University of Chinese Medicine. Among them, 521 images were provided for test datasets and 1,147 images were provided for a model training dataset and validation dataset. Landmarks were annotated for acromio-humeral interval (AHI), acromial tilt (AT), and 3 lines in Park’s acromial classification (line huo-acrf, line acro-acro1, and line huo-acro1). R4 radiologist reviewed the means of 3 radiologists as a reference standard. Model performance was assessed by calculating the percentage of correct key points (PCK), intra-class correlation coefficients (ICCs), Pearson’s correlation coefficients, mean absolute error, and root mean square error. The reliability of R1, R2, R3, AI with R4 and inter-observer reliability of R1, R2, and R3 for acromial morphology classification were assessed by Cohen’s kappa coefficient. Results: Within the 3-mm threshold, the PCK of the model ranged from 74% to 100%. Compared to the reference standard, the model had reliable measurement of AHI, AT, line huo-acrf, line acro-acro1, line huo-acro1 (ICC =0.73–0.94) and moderate reliability of acromial morphology classification (k=0.50–0.56). Conclusions: The cascaded HRNet developed in this study can automatically measure morphological parameters of the shoulder. It may aid early clinical screening for shoulder disorders and assist physicians in treatment decisions.


  • Performance evaluation of a deep learning-based cascaded HRNet model for automatic measurement of X-ray imaging parameters of lumbar sagittal curvature

    by Yuhua Wu, Xiaofei Chen, Fuwen Dong, Linyang He, Guohua Cheng, Yuwen Zheng, Chunyu Ma, Hongyan Yao, Sheng Zhou

    Purpose To develop a deep learning-based cascaded HRNet model, in order to automatically measure X-ray imaging parameters of lumbar sagittal curvature and to evaluate its prediction performance. Methods A total of 3730 lumbar lateral digital radiography (DR) images were collected from picture archiving and communication system (PACS). Among them, 3150 images were randomly selected as the training dataset and validation dataset, and 580 images as the test dataset. The landmarks of the lumbar curve index (LCI), lumbar lordosis angle (LLA), sacral slope (SS), lumbar lordosis index (LLI), and the posterior edge tangent angle of the vertebral body (PTA) were identified and marked. The measured results of landmarks on the test dataset were compared with the mean values of manual measurement as the reference standard. Percentage of correct key-points (PCK), intra-class correlation coefficient (ICC), Pearson correlation coefficient (r), mean absolute error (MAE), mean square error (MSE), root-mean-square error (RMSE), and Bland–Altman plot were used to evaluate the performance of the cascade HRNet model. Results The PCK of the cascaded HRNet model was 97.9–100% in the 3 mm distance threshold. The mean differences between the reference standard and the predicted values for LCI, LLA, SS, LLI, and PTA were 0.43 mm, 0.99°, 1.11°, 0.01 mm, and 0.23°, respectively. There were strong correlation and consistency of the five parameters between the cascaded HRNet model and manual measurements (ICC = 0.989–0.999, R = 0.991–0.999, MAE = 0.63–1.65, MSE = 0.61–4.06, RMSE = 0.78–2.01). Conclusion The cascaded HRNet model based on deep learning algorithm could accurately identify the sagittal curvature-related landmarks on lateral lumbar DR images and automatically measure the relevant parameters, which is of great significance in clinical application.