Nurhani Aryana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nurhani Aryana has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Fransiska Sri Herwahyu Krismastuti
Research Center for Chemistry, National Research and Innovation Agency, Building 452, Kawasan Puspiptek, Serpong, Tangerang Selatan, Indonesia
2 shared publications- Osi Arutanti
Research Center for Chemistry, National Research and Innovation Agency Building 452, Kawasan Puspiptek, Serpong, Tangerang Selatan, Indonesia
1 shared publication Witta Kartika Restu
Research Center for Chemistry, National Research and Innovation Agency Building 452, Kawasan Puspiptek, Serpong, Tangerang Selatan, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2902 (1)
The preparation of lignin nanoparticles: Comparison between homogenization and ultrasonication treatments following anti-solvent precipitation method
The combination of the anti-solvent precipitation method with mechanical treatments in the production of lignin nanoparticles (LNP) has been performed in several studies. However, literature explaining the effect of different mechanical treatments on the properties of the obtained nanoparticles is still lacking. In this work, two mechanical treatments, namely, homogenization at 12,000 rpm and ultrasonication at 600 W, were carried out after the anti-solvent precipitation method, and their influences on the properties of the obtained LNP were compared. Alkali lignin was used as the starting lignin. The anti-solvent precipitation method was performed by using acetone/water with a ratio of 7:3 as the lignin solvent and water as the anti-solvent. Subsequently, two different mechanical treatments were applied to the resulting solution for 10 min, respectively. The results showed that the ultrasonication treatment after the anti-solvent precipitation method yields LNP with a more negative surface charge (-36.6±0.4 mV) than the homogenization treatment. As the consequence, these LNP have better stability in aqueous solution at room temperature for 3 months. In addition, the ultrasonication treatment generates a higher surface area, small pore size and pore volume, and repeatable and reproducible advantages. The current research showed that this method could effectively control the physicochemical properties of LNP so that it can be adapted to broad applications such as sensors, biocatalysts, and nano-adsorbent in further research.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2902 (1)
Open AccessThe preparation of lignin nanoparticles: Comparison between homogenization and ultrasonication treatments following anti-solvent precipitation method
The combination of the anti-solvent precipitation method with mechanical treatments in the production of lignin nanoparticles (LNP) has been performed in several studies. However, literature explaining the effect of different mechanical treatments on the properties of the obtained nanoparticles is still lacking. In this work, two mechanical treatments, namely, homogenization at 12,000 rpm and ultrasonication at 600 W, were carried out after the anti-solvent precipitation method, and their influences on the properties of the obtained LNP were compared. Alkali lignin was used as the starting lignin. The anti-solvent precipitation method was performed by using acetone/water with a ratio of 7:3 as the lignin solvent and water as the anti-solvent. Subsequently, two different mechanical treatments were applied to the resulting solution for 10 min, respectively. The results showed that the ultrasonication treatment after the anti-solvent precipitation method yields LNP with a more negative surface charge (-36.6±0.4 mV) than the homogenization treatment. As the consequence, these LNP have better stability in aqueous solution at room temperature for 3 months. In addition, the ultrasonication treatment generates a higher surface area, small pore size and pore volume, and repeatable and reproducible advantages. The current research showed that this method could effectively control the physicochemical properties of LNP so that it can be adapted to broad applications such as sensors, biocatalysts, and nano-adsorbent in further research.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2902 (1)
Study on the performance evaluation of testing laboratories based on the reported estimation of measurement uncertainties in Indonesian proficiency testing schemes
Research Center for Chemistry-Indonesian Institute of Sciences (RCChem-LIPI) has organized proficiency testing (PT) schemes for testing laboratories in Indonesia and some other countries. Since 2013, the test results together with their estimation of measurement uncertainties were collected from the participants. Z-score was used to evaluate the performance of participants and the reported measurement uncertainties were used for information purposes only. A little information is available for the competence development in the estimation of measurement uncertainties in developing countries, especially in Indonesia. In addition, through the reported estimation of uncertainties in the PT schemes, they might be over-or underestimated. This paper is aimed to study the estimated measurement uncertainty reported by the participants in Indonesian PT schemes to get a possibility of including the estimation of uncertainty in the future assessment. The participants were requested to perform analysis of the test samples by using their routine methods and report the test results, including their estimation of uncertainties in provided result report form. Performance scores were calculated by zeta-score and were then compared with z-score from the real PT schemes. The relationship between the reported measurement uncertainty with the accreditation status, instrument employed and analytical method selected by the laboratories were observed. From this study, it was found that the reported uncertainties were varied greatly although some participants used the same analytical instrument or analytical method. The over-and underestimated uncertainties reported by some laboratories in comparison with the correlated σpt had affected the zeta-score.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2902 (1)
Open AccessStudy on the performance evaluation of testing laboratories based on the reported estimation of measurement uncertainties in Indonesian proficiency testing schemes
Research Center for Chemistry-Indonesian Institute of Sciences (RCChem-LIPI) has organized proficiency testing (PT) schemes for testing laboratories in Indonesia and some other countries. Since 2013, the test results together with their estimation of measurement uncertainties were collected from the participants. Z-score was used to evaluate the performance of participants and the reported measurement uncertainties were used for information purposes only. A little information is available for the competence development in the estimation of measurement uncertainties in developing countries, especially in Indonesia. In addition, through the reported estimation of uncertainties in the PT schemes, they might be over-or underestimated. This paper is aimed to study the estimated measurement uncertainty reported by the participants in Indonesian PT schemes to get a possibility of including the estimation of uncertainty in the future assessment. The participants were requested to perform analysis of the test samples by using their routine methods and report the test results, including their estimation of uncertainties in provided result report form. Performance scores were calculated by zeta-score and were then compared with z-score from the real PT schemes. The relationship between the reported measurement uncertainty with the accreditation status, instrument employed and analytical method selected by the laboratories were observed. From this study, it was found that the reported uncertainties were varied greatly although some participants used the same analytical instrument or analytical method. The over-and underestimated uncertainties reported by some laboratories in comparison with the correlated σpt had affected the zeta-score.