Ye Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ye Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Feng Ouyang
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China; Clinical Research Center for Medical Imaging in Jiangxi Province, Nanchang, China
2 shared publications - Jie Liu
Department of Radiology, First Affiliated Hospital of Nanchang University, Nanchang, China
2 shared publications - Qin Wu
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China; Clinical Research Center for Medical Imaging in Jiangxi Province, Nanchang, China
2 shared publications - Xianjun Zeng
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
2 shared publications - Fuqing Zhou
Department of Radiology, The First Affiliated Hospital, Nanchang University, Nanchang, China
1 shared publication - Laisheng Pan
Department of Neurosurgery, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China 413006210176@.ncu.edu.cn
1 shared publication
Latest Publications
- 11 July 2026
- Published by Springer Nature in European Spine Journal
- p. 1-9
Multimodal MRI features of spinal perimedullary versus dural arteriovenous fistulas: an exploratory analysis
Objective Differentiation between spinal dural arteriovenous fistula (SDAVF) and perimedullary arteriovenous fistula (SPAVF) is crucial for treatment planning, but reliable non-invasive modalities remain limited. This study aimed to identify discriminative multimodal MRI features for differentiating SPAVF from SDAVF. Methods This retrospective study enrolled 34 patients (13 SPAVF, 21 SDAVF) confirmed by digital subtraction angiography (DSA) between January 2016 and December 2025. All patients underwent conventional T2-weighted imaging (T2WI), T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (T2W-SPACE), and contrast-enhanced magnetic resonance angiography (CE-MRA). Two neuroradiologists independently evaluated multimodal imaging characteristics. Diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis with bootstrap resampling. Results SPAVF predominantly demonstrated anterior/posterior spinal artery supply (84.61% vs. 0%, P < 0.001), multiple feeding arteries (61.54% vs. 4.76%, P < 0.001), and caudal venous drainage (53.85% vs. 9.52%, P = 0.004) compared with SDAVF. On T2W-SPACE, SPAVF exhibited significantly larger maximum PFV caliber (5.04 mm vs. 1.74 mm, P < 0.001), partial flow void signal (76.92% vs. 0%, P < 0.001), and pial surface fistula location (100% vs. 0%, P < 0.001). CE-MRA revealed larger fistula caliber in SPAVF (5.22 mm vs. 3.21 mm, P < 0.001). ROC analysis demonstrated excellent discriminatory power for SPACE maximum PFV caliber (AUC, 0.96; 95% CI 0.85–0.99; P < 0.001) and CE-MRA fistula caliber (AUC, 0.92; 95% CI 0.76–0.98; P < 0.001). Conclusion T2W-SPACE and CE-MRA enables accurate non-invasive differentiation of SPAVF from SDAVF. SPACE maximum PFV caliber and CE-MRA fistula caliber serve as robust quantitative biomarkers, providing reliable preoperative guidance and potentially reducing dependence on diagnostic DSA.
- 11 July 2026
- Published by Springer Nature in European Spine Journal
- p. 1-9
Multimodal MRI features of spinal perimedullary versus dural arteriovenous fistulas: an exploratory analysis
Objective Differentiation between spinal dural arteriovenous fistula (SDAVF) and perimedullary arteriovenous fistula (SPAVF) is crucial for treatment planning, but reliable non-invasive modalities remain limited. This study aimed to identify discriminative multimodal MRI features for differentiating SPAVF from SDAVF. Methods This retrospective study enrolled 34 patients (13 SPAVF, 21 SDAVF) confirmed by digital subtraction angiography (DSA) between January 2016 and December 2025. All patients underwent conventional T2-weighted imaging (T2WI), T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (T2W-SPACE), and contrast-enhanced magnetic resonance angiography (CE-MRA). Two neuroradiologists independently evaluated multimodal imaging characteristics. Diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis with bootstrap resampling. Results SPAVF predominantly demonstrated anterior/posterior spinal artery supply (84.61% vs. 0%, P < 0.001), multiple feeding arteries (61.54% vs. 4.76%, P < 0.001), and caudal venous drainage (53.85% vs. 9.52%, P = 0.004) compared with SDAVF. On T2W-SPACE, SPAVF exhibited significantly larger maximum PFV caliber (5.04 mm vs. 1.74 mm, P < 0.001), partial flow void signal (76.92% vs. 0%, P < 0.001), and pial surface fistula location (100% vs. 0%, P < 0.001). CE-MRA revealed larger fistula caliber in SPAVF (5.22 mm vs. 3.21 mm, P < 0.001). ROC analysis demonstrated excellent discriminatory power for SPACE maximum PFV caliber (AUC, 0.96; 95% CI 0.85–0.99; P < 0.001) and CE-MRA fistula caliber (AUC, 0.92; 95% CI 0.76–0.98; P < 0.001). Conclusion T2W-SPACE and CE-MRA enables accurate non-invasive differentiation of SPAVF from SDAVF. SPACE maximum PFV caliber and CE-MRA fistula caliber serve as robust quantitative biomarkers, providing reliable preoperative guidance and potentially reducing dependence on diagnostic DSA.
- 7 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4111-4117
The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis
Objective Spinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM. Methods Retrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients. Results The clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula. Conclusion The CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.
- 7 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4111-4117
The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis
Objective Spinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM. Methods Retrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients. Results The clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula. Conclusion The CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.