Weiwen Zheng
Research Subjects
Weiwen Zheng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jia Weng
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication - Jisheng Lin
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication - Peining Zhu
Guangdong Tianxin Electric Power Engineering Testing Co., Ltd., Guangzhou 510663, China
1 shared publication - Wanxun Li
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication - Weijie Chen
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication - Yuequ Lin
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication
Latest Publications
- Open Access
Research on Stability of Dam Substation on Inclined Soft Soil Foundation Reinforced by Pile Foundation
For the construction of dam substations in coastal or mountainous areas, inclined soft soil foundations are very common. The unique engineering characteristics of inclined soft soil foundations can bring great difficulties to the construction of dam substations. In this paper, a pile foundation reinforcement dam slope model on an inclined soft soil foundation is established; the influence of different pile spacings, the pile length, and the soft soil foundation angle on the slope safety factor is studied; and the failure mechanism and stability of pile-supported dam slope foundation are analyzed. The research results indicate that pile foundation reinforcement can reduce the deformation of the dam slope foundation and improve stability. The pile layout has an important impact on stability, but a change in the pile spacing has little effect on the settlement surface at the bottom of the dam slope. The pile length has a significant impact on the safety of the slope within a certain range. The main stress area of the pile is 0–2 m above the pile, and its main deformation is the lateral deformation of the upper part of the pile. The research results of this article can provide parameter support and theoretical guidance for the construction of dam substations.
Open AccessResearch on Stability of Dam Substation on Inclined Soft Soil Foundation Reinforced by Pile Foundation
For the construction of dam substations in coastal or mountainous areas, inclined soft soil foundations are very common. The unique engineering characteristics of inclined soft soil foundations can bring great difficulties to the construction of dam substations. In this paper, a pile foundation reinforcement dam slope model on an inclined soft soil foundation is established; the influence of different pile spacings, the pile length, and the soft soil foundation angle on the slope safety factor is studied; and the failure mechanism and stability of pile-supported dam slope foundation are analyzed. The research results indicate that pile foundation reinforcement can reduce the deformation of the dam slope foundation and improve stability. The pile layout has an important impact on stability, but a change in the pile spacing has little effect on the settlement surface at the bottom of the dam slope. The pile length has a significant impact on the safety of the slope within a certain range. The main stress area of the pile is 0–2 m above the pile, and its main deformation is the lateral deformation of the upper part of the pile. The research results of this article can provide parameter support and theoretical guidance for the construction of dam substations.