Jerome Aicart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jerome Aicart has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Julie Mougin
Adjointe au directeur en charge des technologies hydrogène, CEA/LITEN
4 shared publications Lucas Champelovier
3 shared publicationsM. Petitjean
3 shared publications- Alexander Surrey
Sunfire GmbH Dresden Germany
2 shared publications Bastien Gervasoni
2 shared publications- Brigitte Gonzalez2 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 277
Stabilizing lifetime syngas production of thermoneutral H2O-CO2 co-electrolysis
- 21 September 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 277
Open AccessStabilizing lifetime syngas production of thermoneutral H2O-CO2 co-electrolysis
- Open Access
- 16 July 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 258
Manufacturing and long-term potentio-galvanostatic operation of high temperature electrolysis stacks in the 10-to-20 kWDC power range
- 16 July 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 258
Open AccessManufacturing and long-term potentio-galvanostatic operation of high temperature electrolysis stacks in the 10-to-20 kWDC power range
- Open Access
- 9 April 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 231
Lifespan evaluation and benchmarking of novel high temperature electrolysis stack prototypes scalable for industrialization
- 9 April 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 231
Open AccessLifespan evaluation and benchmarking of novel high temperature electrolysis stack prototypes scalable for industrialization
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Modeling and experimental validation of high temperature steam and carbon dioxide co-electrolysis
Modélisation et validation expérimentale d'un co-électrolyseur de la vapeur d'eau et du dioxyde de carbone à haute température: Cette étude porte sur la co-électrolyse de H2O et CO2 à 800°C dans une cellule à oxydessolides. Un modèle détaillé a été développé afin de rendre compte des phénomènesélectrochimiques, chimiques, thermiques et de transferts de matière, et introduisant unereprésentation macroscopique du mécanisme de co-électrolyse. Il permet d’estimer lesperformances et les compositions en sortie de cellule. Un protocole expérimental, visant àvalider les principales hypothèses de ce modèle, a été appliqué à deux types de cellulecommerciale à cathode support. À partir de courbes de polarisations, obtenues en électrolyseet en co-électrolyse, ainsi que d’analyses gaz, les densités de courant d’échange, illustrant lescinétiques électrochimiques, ont pu être estimées, et le mécanisme proposé a pu être validé.L’analyse des simulations a permis l’identification des processus limitant la co-électrolyse, laproposition de voies d’optimisation et l’établissement des cartographies de fonctionnement.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Modeling and experimental validation of high temperature steam and carbon dioxide co-electrolysis
Modélisation et validation expérimentale d'un co-électrolyseur de la vapeur d'eau et du dioxyde de carbone à haute température: Cette étude porte sur la co-électrolyse de H2O et CO2 à 800°C dans une cellule à oxydessolides. Un modèle détaillé a été développé afin de rendre compte des phénomènesélectrochimiques, chimiques, thermiques et de transferts de matière, et introduisant unereprésentation macroscopique du mécanisme de co-électrolyse. Il permet d’estimer lesperformances et les compositions en sortie de cellule. Un protocole expérimental, visant àvalider les principales hypothèses de ce modèle, a été appliqué à deux types de cellulecommerciale à cathode support. À partir de courbes de polarisations, obtenues en électrolyseet en co-électrolyse, ainsi que d’analyses gaz, les densités de courant d’échange, illustrant lescinétiques électrochimiques, ont pu être estimées, et le mécanisme proposé a pu être validé.L’analyse des simulations a permis l’identification des processus limitant la co-électrolyse, laproposition de voies d’optimisation et l’établissement des cartographies de fonctionnement.
- Open Access
- 26 March 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 677
Assessing co-electrolysis stability with metal-supported solid oxide cells under dynamic current conditions
- 26 March 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 677
Open AccessAssessing co-electrolysis stability with metal-supported solid oxide cells under dynamic current conditions
- Open Access
- 7 February 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 141, 1165-1171
Design, laboratory characterization, factory acceptance tests and installation of a 2.6 MW High temperature steam electrolyser in a refinery
- 7 February 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 141, 1165-1171
Open AccessDesign, laboratory characterization, factory acceptance tests and installation of a 2.6 MW High temperature steam electrolyser in a refinery
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 93, 562-573
Component analysis of a 25-cell stack following 6.7 kh of high temperature electrolysis
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 93, 562-573
Component analysis of a 25-cell stack following 6.7 kh of high temperature electrolysis
- 1 October 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (10) , 104511
Development of a Versatile and Reversible Multi-Stack Solid Oxide Cell System Towards Operation Strategies Optimization
Solid oxide cell technology is currently rapidly industrializing. To investigate operational strategies, CEA-Liten has designed and assembled a four-stack reversible solid oxide cell (rSOC) toolbox system. Each stack comprised 25 cathode-supported cells with a 100 cm2 active area, amounting to a nominal electrolysis module power of approximately 13 kWDC at −1 A cm−2. Most of the present work reports on preliminary functional validation carried out in a two-stack configuration. Thermal losses have been quantified and their sources identified. While the hotbox is showing high intrinsic performances, the overall losses increased twofold when pass-through piping and current connections are taken into account. Module fluid distribution was verified to be homogeneous, and did not affect nominal stack operation. A test sequence of 3.5 kh is presented. Over the first 1.1 kh, the stacks behavior was similar to that of stack tested on a bench, indicating adequate control of the system. However, continued testing highlighted that stack degradation was significantly increased. A detailed analysis of efficiency was then conducted after thermal stabilization and in the nominal four-stack configuration. A maximum efficiency of 79%LHV was recorded when steam generation was excluded.
- 1 October 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (10) , 104511
Development of a Versatile and Reversible Multi-Stack Solid Oxide Cell System Towards Operation Strategies Optimization
Solid oxide cell technology is currently rapidly industrializing. To investigate operational strategies, CEA-Liten has designed and assembled a four-stack reversible solid oxide cell (rSOC) toolbox system. Each stack comprised 25 cathode-supported cells with a 100 cm2 active area, amounting to a nominal electrolysis module power of approximately 13 kWDC at −1 A cm−2. Most of the present work reports on preliminary functional validation carried out in a two-stack configuration. Thermal losses have been quantified and their sources identified. While the hotbox is showing high intrinsic performances, the overall losses increased twofold when pass-through piping and current connections are taken into account. Module fluid distribution was verified to be homogeneous, and did not affect nominal stack operation. A test sequence of 3.5 kh is presented. Over the first 1.1 kh, the stacks behavior was similar to that of stack tested on a bench, indicating adequate control of the system. However, continued testing highlighted that stack degradation was significantly increased. A detailed analysis of efficiency was then conducted after thermal stabilization and in the nominal four-stack configuration. A maximum efficiency of 79%LHV was recorded when steam generation was excluded.
- 21 February 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 60, 531-539
Lifespan evaluation of two 30-cell electrolyte-supported stacks for hydrogen production by high temperature electrolysis
- 21 February 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 60, 531-539
Lifespan evaluation of two 30-cell electrolyte-supported stacks for hydrogen production by high temperature electrolysis
- Open Access
- 3 October 2023
- Published by Wiley in Fuel Cells
- Vol. 23 (6) , 463-473
Benchmark study of performances and durability between different stack technologies for high temperature electrolysis
In the current landscape of high temperature electrolysis, mainly two solid oxide cell (SOC) technologies are being used: electrolyte‐supported and cathode‐supported SOCs. The geometrical differences, namely the thickness of the electrolyte, can lead to vastly different operating temperatures. Since most phenomena affecting performance and durability remain thermally activated, comparing stack technologies can be a difficult endeavor at best.While the most visible goal of the European project MultiPLHY consists of Sunfire GmbH building the first multi‐megawatt solid oxide electrolyzer, a work package is being dedicated to stack testing in a laboratory environment. A harmonized protocol was first elaborated to allow comparing different stack technologies. It includes the recording of performance maps, several galvanostatic steps in thermoneutral conditions, as well as load point and thermal cycles. Subsequently, Sunfire operated a pile‐up of two 30‐cell electrolyte‐supported stacks for over 8200 h, while a 25‐cell cathode‐supported stack was tested at CEA for 6800 h.The present article aims at presenting the findings gathered during the implementation of the protocol. This benchmark study puts forward performance maps as well as voltage and stack temperature profiles over time, and discusses some of the difficulties inherent to long‐term testing.
- 3 October 2023
- Published by Wiley in Fuel Cells
- Vol. 23 (6) , 463-473
Open AccessBenchmark study of performances and durability between different stack technologies for high temperature electrolysis
In the current landscape of high temperature electrolysis, mainly two solid oxide cell (SOC) technologies are being used: electrolyte‐supported and cathode‐supported SOCs. The geometrical differences, namely the thickness of the electrolyte, can lead to vastly different operating temperatures. Since most phenomena affecting performance and durability remain thermally activated, comparing stack technologies can be a difficult endeavor at best.While the most visible goal of the European project MultiPLHY consists of Sunfire GmbH building the first multi‐megawatt solid oxide electrolyzer, a work package is being dedicated to stack testing in a laboratory environment. A harmonized protocol was first elaborated to allow comparing different stack technologies. It includes the recording of performance maps, several galvanostatic steps in thermoneutral conditions, as well as load point and thermal cycles. Subsequently, Sunfire operated a pile‐up of two 30‐cell electrolyte‐supported stacks for over 8200 h, while a 25‐cell cathode‐supported stack was tested at CEA for 6800 h.The present article aims at presenting the findings gathered during the implementation of the protocol. This benchmark study puts forward performance maps as well as voltage and stack temperature profiles over time, and discusses some of the difficulties inherent to long‐term testing.