Catalina Baas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Catalina Baas has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ala'A Farkouh
Department of Urology, Loma Linda University Health, Loma Linda, California, USA
2 shared publications - D. Daniel Baldwin
Department of Urology, Loma Linda University Health, Loma Linda, USA
2 shared publications - Daniel R. Peverini
Department of Urology, Loma Linda University Health, Loma Linda, California, USA
2 shared publications - John C. Hartman
Department of Urology, Loma Linda University Health, Loma Linda, California, USA
2 shared publications - Ricky Chen
Department of Urology, Loma Linda University Health, Loma Linda, California, USA
2 shared publications - Akin S. Amasyali
Department of Urology, Loma Linda University Health, Loma Linda, California, USA
1 shared publication
Latest Publications
- 7 February 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (3) , 228-233
Not All Flat-Panel C-Arms Are Created Equal: A Comparison of Three Major Manufacturers
Introduction: Flat-Panel Detector C-arms (FC) are reported to reduce radiation exposure and improve image quality compared to conventional image intensifier C-arms (CC). The purpose of this study was to compare radiation exposure and image quality between three commonly used FCs. Materials and Methods: A cadaver model was placed in prone position to simulate percutaneous nephrolithotomy. We compared three FCs: OEC Elite CFD from GE HealthCare, Zenition 70 from Philips, and Ziehm Vision RFD from Ziehm Imaging. To measure the radiation dose, optically stimulated luminescence dosimeters (OSLDs) were utilized during five 300-second trials, conducted under three settings: automatic exposure control (AEC), AEC with low dose (LD), and LD with the lowest pulse rate (LDLP). Ten blinded urologists evaluated image quality. Data was statistically analyzed using ANOVA and Tukey’s B post-hoc tests. Results: In the AEC setting, the Philips C-arm demonstrated lower ventral OSLD exposure (42,446 mrad) compared to both the GE (51,076 mrad) and Ziehm (83,178 mrad; p<0.001). Similarly, in the LD setting, the Philips C-arm resulted in less ventral OSLD exposure (25,926 mrad) than both Ziehm (30,956 mrad) and GE (38,209 mrad; p<0.001). Meanwhile, in the LDLP setting, the Ziehm C-arm showed less ventral OSLD exposure (4,019 mrad) than both GE (7,418 mrad) and Philips (8,229 mrad; p<0.001). All three manufacturers received adequate image quality ratings at the AEC and LD settings. However, at LDLP, the Ziehm C-arm received inadequate ratings in 8% of images, while both GE and Philips received 100% adequate ratings (p=0.016). Conclusions: Radiation produced by flat-panel C-arms varies dramatically, with the highest exposure (Ziehm) being almost double the lowest (Philips) in AEC. Improved picture quality at the lowest settings may come at the cost of increased radiation dose. Surgeons should carefully select the machine and settings to minimize radiation exposure while still preserving image quality.
- 7 February 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (3) , 228-233
Not All Flat-Panel C-Arms Are Created Equal: A Comparison of Three Major Manufacturers
Introduction: Flat-Panel Detector C-arms (FC) are reported to reduce radiation exposure and improve image quality compared to conventional image intensifier C-arms (CC). The purpose of this study was to compare radiation exposure and image quality between three commonly used FCs. Materials and Methods: A cadaver model was placed in prone position to simulate percutaneous nephrolithotomy. We compared three FCs: OEC Elite CFD from GE HealthCare, Zenition 70 from Philips, and Ziehm Vision RFD from Ziehm Imaging. To measure the radiation dose, optically stimulated luminescence dosimeters (OSLDs) were utilized during five 300-second trials, conducted under three settings: automatic exposure control (AEC), AEC with low dose (LD), and LD with the lowest pulse rate (LDLP). Ten blinded urologists evaluated image quality. Data was statistically analyzed using ANOVA and Tukey’s B post-hoc tests. Results: In the AEC setting, the Philips C-arm demonstrated lower ventral OSLD exposure (42,446 mrad) compared to both the GE (51,076 mrad) and Ziehm (83,178 mrad; p<0.001). Similarly, in the LD setting, the Philips C-arm resulted in less ventral OSLD exposure (25,926 mrad) than both Ziehm (30,956 mrad) and GE (38,209 mrad; p<0.001). Meanwhile, in the LDLP setting, the Ziehm C-arm showed less ventral OSLD exposure (4,019 mrad) than both GE (7,418 mrad) and Philips (8,229 mrad; p<0.001). All three manufacturers received adequate image quality ratings at the AEC and LD settings. However, at LDLP, the Ziehm C-arm received inadequate ratings in 8% of images, while both GE and Philips received 100% adequate ratings (p=0.016). Conclusions: Radiation produced by flat-panel C-arms varies dramatically, with the highest exposure (Ziehm) being almost double the lowest (Philips) in AEC. Improved picture quality at the lowest settings may come at the cost of increased radiation dose. Surgeons should carefully select the machine and settings to minimize radiation exposure while still preserving image quality.
- 1 January 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (1) , 53-59
Time Efficiency and Performance of Single-Use vs Reusable Cystoscopes: A Randomized Benchtop and Simulated Clinical Assessment
Introduction A flexible cystoscope is an indispensable tool for urologists, facilitating a variety of procedures in both the operating room and at bedside. Single-use cystoscopes offer benefits including accessibility and decreased burden for reprocessing. The aims of this study were to compare time efficiency and performance of single-use and reusable cystoscopes. Methods Ten new AmbuⓇ aScopeTM 4 Cysto single-use and two Olympus CYF-5 reusable cystoscopes were compared in simulated bedside cystoscopy and benchtop testing. Ten urologists performed simulated cystoscopy using both cystoscopes in a randomized order. Times for supply-gathering, setup, cystoscopy, cleanup, and cumulative time were recorded, followed by a Likert feedback survey. For benchtop assessment, physical, optical, and functional specifications were assessed and compared between cystoscopes. Results The single-use cystoscope demonstrated shorter supply-gathering, setup, cleanup, and cumulative times (824 vs 1231s; p<0.05) but a comparable cystoscopy time to the reusable cystoscope (202 vs 212s; p=0.322). The single-use cystoscope had a higher image resolution but a narrower field of view. Upward deflection was greater for the single-use cystoscope (214.50° vs 199.45°; p<0.001) but required greater force (2.5x). Working channel diameter and irrigation rate were greater in the reusable cystoscope. While the single-use cystoscope lacked tumor enhancing optical features, it had higher Likert scale scores for Time Efficiency and Overall Satisfaction. Conclusion The single-use cystoscope demonstrates comparable benchtop performance and superior time efficiency compared to reusable cystoscopes. However, the reusable cystoscope has superior optical versatility and flow rate. Knowledge of these differences allow for optimal cystoscope selection based on procedure indication.
- 1 January 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (1) , 53-59
Time Efficiency and Performance of Single-Use vs Reusable Cystoscopes: A Randomized Benchtop and Simulated Clinical Assessment
Introduction A flexible cystoscope is an indispensable tool for urologists, facilitating a variety of procedures in both the operating room and at bedside. Single-use cystoscopes offer benefits including accessibility and decreased burden for reprocessing. The aims of this study were to compare time efficiency and performance of single-use and reusable cystoscopes. Methods Ten new AmbuⓇ aScopeTM 4 Cysto single-use and two Olympus CYF-5 reusable cystoscopes were compared in simulated bedside cystoscopy and benchtop testing. Ten urologists performed simulated cystoscopy using both cystoscopes in a randomized order. Times for supply-gathering, setup, cystoscopy, cleanup, and cumulative time were recorded, followed by a Likert feedback survey. For benchtop assessment, physical, optical, and functional specifications were assessed and compared between cystoscopes. Results The single-use cystoscope demonstrated shorter supply-gathering, setup, cleanup, and cumulative times (824 vs 1231s; p<0.05) but a comparable cystoscopy time to the reusable cystoscope (202 vs 212s; p=0.322). The single-use cystoscope had a higher image resolution but a narrower field of view. Upward deflection was greater for the single-use cystoscope (214.50° vs 199.45°; p<0.001) but required greater force (2.5x). Working channel diameter and irrigation rate were greater in the reusable cystoscope. While the single-use cystoscope lacked tumor enhancing optical features, it had higher Likert scale scores for Time Efficiency and Overall Satisfaction. Conclusion The single-use cystoscope demonstrates comparable benchtop performance and superior time efficiency compared to reusable cystoscopes. However, the reusable cystoscope has superior optical versatility and flow rate. Knowledge of these differences allow for optimal cystoscope selection based on procedure indication.