Adam Trepczynski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adam Trepczynski has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Allan Maas
Research and Development, Aesculap AG, 78532 Tuttlingen, Germany
2 shared publications - Philipp Damm
Julius Wolff Institute, Charite Universitatsmedizin Berlin Campus Charite Mitte: Charite Universitatsmedizin Berlin, Berlin, GERMANY
2 shared publications - Seyyed Hamed Hosseini Nasab
Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
2 shared publications - Thomas M. Grupp
Aesculap AG, Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Munich, Germany
2 shared publications - William R. Taylor
Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
2 shared publications Dominik Deppe
Julius Wolff Institute, Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 31 January 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (2) , 173
Machine Learning-Based Estimation of Knee Joint Mechanics from Kinematic and Neuromuscular Inputs: A Proof-of-Concept Using the CAMS-Knee Datasets
This study explores the feasibility of estimating tibiofemoral joint contact forces using deep learning models trained on in vivo biomechanical data. Leveraging the comprehensive CAMS-Knee datasets, we developed and evaluated two machine learning network architectures, a bidirectional Long Short-Term-Memory Network with a Multilayer Perceptron (biLSTM-MLP) and a Temporal Convolutional Network (TCN) model, to predict medial and lateral knee contact forces (KCFs) across various activities of daily living. Using a leave-one-subject-out validation approach, the biLSTM-MLP model achieved root mean square errors (RMSEs) as low as 0.16 body weight (BW) and Pearson correlation coefficients up to 0.98 for the total KCF () during walking. Although the prediction of individual force components showed slightly lower accuracy, the model consistently demonstrated high predictive accuracy and strong temporal coherence. In contrast to the biLSTM-MLP model, the TCN model showed more variable performance across force components and activities. Leave-one-feature-out analyses underscored the dominant role of lower-limb kinematics and ground reaction forces in driving model accuracy, while EMG features contributed only marginally to the overall predictive performance. Collectively, these findings highlight deep learning as a scalable and reliable alternative to traditional musculoskeletal simulations for personalized knee load estimation, establishing a foundation for future research on larger and more heterogeneous populations.- 31 January 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (2) , 173
Open AccessMachine Learning-Based Estimation of Knee Joint Mechanics from Kinematic and Neuromuscular Inputs: A Proof-of-Concept Using the CAMS-Knee Datasets
This study explores the feasibility of estimating tibiofemoral joint contact forces using deep learning models trained on in vivo biomechanical data. Leveraging the comprehensive CAMS-Knee datasets, we developed and evaluated two machine learning network architectures, a bidirectional Long Short-Term-Memory Network with a Multilayer Perceptron (biLSTM-MLP) and a Temporal Convolutional Network (TCN) model, to predict medial and lateral knee contact forces (KCFs) across various activities of daily living. Using a leave-one-subject-out validation approach, the biLSTM-MLP model achieved root mean square errors (RMSEs) as low as 0.16 body weight (BW) and Pearson correlation coefficients up to 0.98 for the total KCF () during walking. Although the prediction of individual force components showed slightly lower accuracy, the model consistently demonstrated high predictive accuracy and strong temporal coherence. In contrast to the biLSTM-MLP model, the TCN model showed more variable performance across force components and activities. Leave-one-feature-out analyses underscored the dominant role of lower-limb kinematics and ground reaction forces in driving model accuracy, while EMG features contributed only marginally to the overall predictive performance. Collectively, these findings highlight deep learning as a scalable and reliable alternative to traditional musculoskeletal simulations for personalized knee load estimation, establishing a foundation for future research on larger and more heterogeneous populations. - Open Access
- 24 September 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 192, 112980
Knee contact force alone is insufficient to validate joint mechanics in musculoskeletal models
- 24 September 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 192, 112980
Open AccessKnee contact force alone is insufficient to validate joint mechanics in musculoskeletal models
- Open Access
- 12 October 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1284091
Lower-limb internal loading and potential consequences for fracture healing
Introduction: Mechanical loading is known to determine the course of bone fracture healing. We hypothesise that lower limb long bone loading differs with knee flexion angle during walking and frontal knee alignment, which affects fracture healing success.Materials and methods: Using our musculoskeletal in silico modelling constrained against in vivo data from patients with instrumented knee implants allowed us to assess internal loads in femur and tibia. These internal forces were associated with the clinical outcome of fracture healing in a relevant cohort of 178 extra-articular femur and tibia fractures in patients using a retrospective approach.Results: Mean peak forces differed with femoral compression (1,330–1,936 N at mid-shaft) amounting to about half of tibial compression (2,299–5,224 N). Mean peak bending moments in the frontal plane were greater in the femur (71–130 Nm) than in the tibia (from 26 to 43 Nm), each increasing proximally. Bending in the sagittal plane showed smaller mean peak bending moments in the femur (−38 to 43 Nm) reaching substantially higher values in the tibia (−63 to −175 Nm) with a peak proximally. Peak torsional moments had opposite directions for the femur (−13 to −40 Nm) versus tibia (15–48 Nm) with an increase towards the proximal end in both. Femoral fractures showed significantly lower scores in the modified Radiological Union Scale for Tibia (mRUST) at last follow-up (p < 0.001) compared to tibial fractures. Specifically, compression (r = 0.304), sagittal bending (r = 0.259), and frontal bending (r = −0.318) showed strong associations (p < 0.001) to mRUST at last follow-up. This was not the case for age, body weight, or localisation alone.Discussion: This study showed that moments in femur and tibia tend to decrease towards their distal ends. Tibial load components were influenced by knee flexion angle, especially at push-off, while static frontal alignment played a smaller role. Our results indicate that femur and tibia are loaded differently and thus require adapted fracture fixation considering load components rather than just overall load level.
- 12 October 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1284091
Open AccessLower-limb internal loading and potential consequences for fracture healing
Introduction: Mechanical loading is known to determine the course of bone fracture healing. We hypothesise that lower limb long bone loading differs with knee flexion angle during walking and frontal knee alignment, which affects fracture healing success.Materials and methods: Using our musculoskeletal in silico modelling constrained against in vivo data from patients with instrumented knee implants allowed us to assess internal loads in femur and tibia. These internal forces were associated with the clinical outcome of fracture healing in a relevant cohort of 178 extra-articular femur and tibia fractures in patients using a retrospective approach.Results: Mean peak forces differed with femoral compression (1,330–1,936 N at mid-shaft) amounting to about half of tibial compression (2,299–5,224 N). Mean peak bending moments in the frontal plane were greater in the femur (71–130 Nm) than in the tibia (from 26 to 43 Nm), each increasing proximally. Bending in the sagittal plane showed smaller mean peak bending moments in the femur (−38 to 43 Nm) reaching substantially higher values in the tibia (−63 to −175 Nm) with a peak proximally. Peak torsional moments had opposite directions for the femur (−13 to −40 Nm) versus tibia (15–48 Nm) with an increase towards the proximal end in both. Femoral fractures showed significantly lower scores in the modified Radiological Union Scale for Tibia (mRUST) at last follow-up (p < 0.001) compared to tibial fractures. Specifically, compression (r = 0.304), sagittal bending (r = 0.259), and frontal bending (r = −0.318) showed strong associations (p < 0.001) to mRUST at last follow-up. This was not the case for age, body weight, or localisation alone.Discussion: This study showed that moments in femur and tibia tend to decrease towards their distal ends. Tibial load components were influenced by knee flexion angle, especially at push-off, while static frontal alignment played a smaller role. Our results indicate that femur and tibia are loaded differently and thus require adapted fracture fixation considering load components rather than just overall load level.