    An Open‐Source, Reproducible MRI Data Acquisition and Reconstruction Workflow Using Pulseq: Multi‐Site and Cross‐Vendor Validation

    by Qingping Chen, Thomas H. M. Roos, Amaya Murguia, Yuhai Xie, Zheng Liu, Pengcheng Xu, Shohei Fujita, Sebastian Littin, Yogesh Rathi, Jiayu Zhu, et al.

    Purpose: Reproducibility in MRI is limited by variability in data acquisition, formatting, and reconstruction across sites and vendors. This work aimed to mitigate these challenges through an open‐source, vendor‐independent workflow originally developed for the 2023–24 ISMRM Repeat It with Me: Reproducibility Team Challenge . Methods: Pulseq, extended with advanced features including LABELs and Sequence Definitions for k‐space description and execution instructions, was used to harmonize data acquisition. Pulseq‐generated raw k‐space data were converted into the MRD format using these metadata. Open‐source, vendor‐independent image reconstruction and post‐processing were performed with Gadgetron. Additionally, vendor‐native online reconstructions on Siemens platforms (ICE and OpenRecon) were enabled for Pulseq‐based sequences. The workflow was validated using MPRAGE and EPI protocols in phantoms and in vivo across nine scanners from five sites and four vendors. Vendor‐native acquisition and reconstruction protocols were executed for comparison. Results: Pulseq‐based sequences executed successfully on all systems, with all data converted and reconstructed without errors. Pulseq‐based, Gadgetron‐reconstructed images showed good agreement with corresponding vendor‐native images across scanners; however, qualitative and quantitative differences remained. Despite detailed natural‐language descriptions and meticulous console configuration, vendor‐native protocols introduced subtle but notable cross‐platform differences in sequence execution and reconstruction. In contrast, the proposed workflow achieved highly consistent sequence execution via Pulseq and standardized reconstruction through Gadgetron across scanners. Conclusion: We established an open‐source MRI workflow that harmonizes data acquisition, formatting, and reconstruction across sites and vendors. This workflow represents a critical step toward fully open and reproducible MRI, facilitating transparency, standardization, and collaboration across the research community.


  • Open Access

    pTx‐Pulseq in hybrid sequences: Accessible and advanced hybrid open‐source MRI sequences on Philips scanners

    by Thomas H. M. Roos, Edwin Versteeg, Mark Gosselink, Hans Hoogduin, Kyung Min Nam, Nicolas Boulant, Vincent Gras, Franck Mauconduit, Dennis W. J. Klomp, Jeroen C. W. Siero, et al.

    Purpose: To enhance the accessibility of advanced pulse sequences, or parts thereof, through the open‐source Pulseq framework. This work extends the Pulseq framework to Philips MRI systems and incorporates dynamic parallel‐transmit (pTx) capabilities within the constraints of the existing Pulseq format. This enables the hybrid use of Pulseq sequences within the native vendor's scans, leveraging the combined strengths of both approaches. We showcase a new possibility of these techniques: the use of a portable cross‐vendor universal pulse (UP) excitation in a native scan.Methods: pTx‐Pulseq was implemented to add full dynamic pTx within the Pulseq specification. We developed a Pulseq interpreter for Philips systems, supporting both Pulseq‐only and hybrid sequences. The hybrid mode was used to integrate a UP from the PASTeUR package into a vendor's native scan. Simulation experiments, safety validations, field measurements, and imaging experiments in phantom and in vivo were conducted to verify the interpreter's and UP's functionality.Results: The interpreter executed Pulseq sequences on a Philips 7T system, accurately reproducing gradient waveforms and dynamic pTx sequences. The real‐time safety systems operated correctly. Phantom and in vivo scans demonstrated comparable image quality to native sequences, validating the effectiveness of the interpreter and the successful cross‐vendor use of universal pulses.Conclusion: The successful cross‐vendor application of a universal pulse through pTx‐Pulseq in a hybrid sequence demonstrates how advanced MRI techniques can be made accessible. This not only highlights the flexibility and extensibility of Pulseq but also sets the stage for rapid clinical translation of innovative imaging techniques.


  • Open Access

    Feasibility of strong diffusion encoding and fast readout using a plug‐and‐play head gradient insert at 7 T

    by G. C. Arends, E. Versteeg, A. De Luca, F. Marc, T. H. M. Roos, D. W. J. Klomp, M. Froeling, J. C. W. Siero, C. M. W. Tax

    Purpose: Diffusion weighting is achieved by the application of external field gradients typically for tens of milliseconds, during which the signal also substantially decays due to inherent T2 relaxation. Employing strong gradients will shorten the echo time (TE) and increase the signal‐to‐noise ratio. This study demonstrates a proof‐of‐principle of using an ultrastrong head gradient insert for diffusion MRI at 7 T.Methods: A lightweight (45 kg) single‐axis gradient coil operating in the z‐direction was interfaced with a 7 T system and operated as an additional fourth‐gradient axis to the whole‐body gradient setup. Several diffusion MRI experiments were conducted to compare acquisitions taken with a gradient insert operating at full capacity (200 mT/m and 1300 T/m/s) to those using conventional gradient strengths (40–80 mT/m and 200 T/m/s).Results: A shorter TE of (28.8, 32.4, 38.5, 48.7) ms was achieved using the insert gradient at full capability for readout and diffusion encoding, compared to (49.7, 54.5, 65.9, 85.5) ms (80 mT/m) or (59.9, 68.8, 88.3, 120.9) ms (40 mT/m) for b = (0, 500, 1000, 3000, 10 000) s/mm2 using conventional gradient strength. A SNR increase for all b‐value acquisitions was observed. When using strong gradients for readout, TE was shortened by 20 ms, and a lower degree of geometrical distortions was observed.Conclusion: The results illustrate a successful proof‐of‐concept for performing diffusion MRI using a plug‐and‐play head gradient insert at 7 T. Use of low‐cost gradient inserts could make advanced diffusion MRI experiments more widely available.


  • Open Access

    Open-source Pulseq sequences on Philips MRI scanners

    by Thomas H. M. Roos, Edwin Versteeg, Dennis W. J. Klomp, Jeroen C. W. Siero, Jannie P. Wijnen

    Purpose: This work aims to address the limitations faced by researchers in developing and sharing new MRI sequences by implementing an interpreter for the open-source MRI pulse sequence format, Pulseq, on a Philips MRI scanner. Methods: The implementation involved modifying a few source code files to create a Pulseq interpreter for the Philips MRI system. Validation experiments were conducted using simulations and phantom scans performed on a 7T Achieva MRI system. The observed sequence and waveforms were compared to the intended ones, and the gradient waveforms produced by the scanner were verified using a field camera. Image reconstruction was performed using the raw k-space samples acquired from both the native vendor environment and the Pulseq interpreter. Results: The reconstructed images obtained through the Pulseq implementation were found to be comparable to those obtained through the native implementation. The performance of the Pulseq interpreter was assessed by profiling the CPU utilization of the MRI spectrometer, showing minimal resource utilization for certain sequences. Conclusion: The successful implementation of the Pulseq interpreter on the Philips MRI scanner demonstrates the feasibility of utilizing Pulseq sequences on Philips MRI scanners. This provides an open-source platform for MRI sequence development, facilitating collaboration among researchers and accelerating scientific progress in the field of MRI.

  • Open Access

    Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit kT‐point pulses and Fourier phase‐encoded DREAMB1+ mapping

    by Bobby A. Runderkamp, Thomas Roos, Wietske van der Zwaag, Gustav J. Strijkers, Matthan W. A. Caan, Aart J. Nederveen

    Purpose: To obtain homogeneous signal throughout the human liver at 7 T. Flip angle (FA) shimming in 7T whole‐liver imaging was performed through parallel‐transmit kT‐point pulses based on subject‐specific multichannel absolute maps from Fourier phase‐encoded dual refocusing echo acquisition mode (PE‐DREAM).Methods: The optimal number of Fourier phase‐encoding steps for PE‐DREAM mapping was determined for a 7T eight‐channel parallel‐transmission system. FA shimming experiments were performed in the liver of 7 healthy subjects with varying body mass index. In these subjects, first shimming and Fourier PE‐DREAM mapping were performed. Subsequently, three small‐flip‐angle 3D gradient‐echo scans were acquired, comparing a circularly polarized (CP) mode, a phase shim, and a kT‐point pulse. Resulting homogeneity was assessed and compared with estimated FA maps and distributions.Results: Fourier PE‐DREAM with 13 phase‐encoding steps resulted in a good tradeoff between accuracy and scan time. Lower coefficient of variation values (average [min‐max] across subjects) of the estimated FA in the volume of interest were observed using kT‐points (7.4 [6.6%–8.0%]), compared with phase shimming (18.8 [12.9%–23.4%], p < 0.001) and CP (43.2 [39.4%–47.1%], p < 0.001). kT‐points delivered whole‐liver images with the nominal FA and the highest degree of homogeneity. CP and phase shimming resulted in either inaccurate or imprecise FA distributions. Here, locations having suboptimal FA in the estimated FA maps corresponded to liver areas suffering from inconsistent signal intensity and T1‐weighting in the gradient‐echo scans.Conclusion: Homogeneous whole‐liver 3D gradient‐echo acquisitions at 7 T can be obtained with eight‐channel kT‐point pulses calculated based on subject‐specific multichannel absolute Fourier PE‐DREAM maps.