An Open‐Source, Reproducible MRI Data Acquisition and Reconstruction Workflow Using Pulseq: Multi‐Site and Cross‐Vendor Validation
Open Access
- 6 August 2026
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2721-2738
Abstract
Purpose: Reproducibility in MRI is limited by variability in data acquisition, formatting, and reconstruction across sites and vendors. This work aimed to mitigate these challenges through an open‐source, vendor‐independent workflow originally developed for the 2023–24 ISMRM Repeat It with Me: Reproducibility Team Challenge . Methods: Pulseq, extended with advanced features including LABELs and Sequence Definitions for k‐space description and execution instructions, was used to harmonize data acquisition. Pulseq‐generated raw k‐space data were converted into the MRD format using these metadata. Open‐source, vendor‐independent image reconstruction and post‐processing were performed with Gadgetron. Additionally, vendor‐native online reconstructions on Siemens platforms (ICE and OpenRecon) were enabled for Pulseq‐based sequences. The workflow was validated using MPRAGE and EPI protocols in phantoms and in vivo across nine scanners from five sites and four vendors. Vendor‐native acquisition and reconstruction protocols were executed for comparison. Results: Pulseq‐based sequences executed successfully on all systems, with all data converted and reconstructed without errors. Pulseq‐based, Gadgetron‐reconstructed images showed good agreement with corresponding vendor‐native images across scanners; however, qualitative and quantitative differences remained. Despite detailed natural‐language descriptions and meticulous console configuration, vendor‐native protocols introduced subtle but notable cross‐platform differences in sequence execution and reconstruction. In contrast, the proposed workflow achieved highly consistent sequence execution via Pulseq and standardized reconstruction through Gadgetron across scanners. Conclusion: We established an open‐source MRI workflow that harmonizes data acquisition, formatting, and reconstruction across sites and vendors. This workflow represents a critical step toward fully open and reproducible MRI, facilitating transparency, standardization, and collaboration across the research community.Keywords
Funding Information
- National Institutes of Health (R01 EB032378)
- National Institutes of Health (U24 NS120056)
- Deutsche Forschungsgemeinschaft (INST 39 1365‐1)
- European Association of National Metrology Institutes (22HLT02 A4IM)
This publication has 49 references indexed in Scilit:
- Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability studyHuman Brain Mapping, 2020
- Pulseq: A rapid and hardware-independent pulse sequence prototyping frameworkMagnetic Resonance in Medicine, 2016
- ISMRM Raw data format: A proposed standard for MRI raw datasetsMagnetic Resonance in Medicine, 2016
- Gradient nonlinearity correction to improve apparent diffusion coefficient accuracy and standardization in the american college of radiology imaging network 6698 breast cancer trialJournal of Magnetic Resonance Imaging, 2015
- Pulse sequence programming in a dynamic visual environment: SequenceTreeMagnetic Resonance in Medicine, 2015
- Distributed MRI reconstruction using gadgetron-based cloud computingMagnetic Resonance in Medicine, 2014
- Gadgetron: An open source framework for medical image reconstructionMagnetic Resonance in Medicine, 2012
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Rapid three‐dimensional T1‐weighted MR imaging with the MP‐RAGE sequenceJournal of Magnetic Resonance Imaging, 1991