WYWataru Yamagata

Wataru Yamagata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wataru Yamagata has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Akiko Kitazume

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications
  • Arisa Takeda

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications
  • Dai Inoue

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications
  • Hideyuki Horike

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications
  • Natsuki Miura

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications
  • Shigetaka Yoshinaga

    Department of Gastroenterology and Hepatology Tokyo Metropolitan Tama Medical Center Tokyo Japan

    2 shared publications

Latest Publications

  • Open Access

    Gastroptosis as a Risk Factor of Stent Migration After Endoscopic Ultrasound‐guided Hepaticogastrostomy: A Case Report

    by Wataru Yamagata, Arisa Takeda, Yuki Fuji, Takuya Yokota, Natsuki Miura, Akiko Kitazume, Dai Inoue, Hideyuki Horike, Shigetaka Yoshinaga, Shin Namiki

    Endoscopic ultrasound‐guided hepaticogastrostomy (EUS‐HGS) has become an established, alternative biliary drainage technique for patients with failed or difficult endoscopic retrograde cholangiopancreatography. Stent migration is a particularly serious adverse event of this method. To minimize the risk of migration, preoperative computed tomography (CT) may be used to confirm the distance between the stomach and the liver. We herein report a rare case of stent migration that occurred despite the use of a long stent. Although preoperative CT demonstrated an acceptable hepaticogastric distance, pronounced gastroptosis involving an excessive, downward extension of the stomach during esophagogastroduodenoscopy on postoperative day 3 led to stent migration. This case highlights the importance of recognizing gastroptosis as a potential risk factor of stent migration following EUS‐HGS.

    • 2 March 2026
      • Vol. 6  (1) , e70307
    Open Access

    Gastroptosis as a Risk Factor of Stent Migration After Endoscopic Ultrasound‐guided Hepaticogastrostomy: A Case Report

    by Wataru Yamagata, Arisa Takeda, Yuki Fuji, Takuya Yokota, Natsuki Miura, Akiko Kitazume, Dai Inoue, Hideyuki Horike, Shigetaka Yoshinaga, Shin Namiki

    Endoscopic ultrasound‐guided hepaticogastrostomy (EUS‐HGS) has become an established, alternative biliary drainage technique for patients with failed or difficult endoscopic retrograde cholangiopancreatography. Stent migration is a particularly serious adverse event of this method. To minimize the risk of migration, preoperative computed tomography (CT) may be used to confirm the distance between the stomach and the liver. We herein report a rare case of stent migration that occurred despite the use of a long stent. Although preoperative CT demonstrated an acceptable hepaticogastric distance, pronounced gastroptosis involving an excessive, downward extension of the stomach during esophagogastroduodenoscopy on postoperative day 3 led to stent migration. This case highlights the importance of recognizing gastroptosis as a potential risk factor of stent migration following EUS‐HGS.

  • Open Access

    Evaluation of the mechanical properties of current biliary self-expandable metallic stents: axial and radial force, and axial force zero border

    by Wataru Yamagata, Toshio Fujisawa, Takashi Sasaki, Rei Ishibashi, Tomotaka Saito, Shuntaro Yoshida, Shizuka No, Kouta Inoue, Yousuke Nakai, Naoki Sasahira, et al.

    Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability.Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated.Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types.Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.