Seyedamin Hashemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seyedamin Hashemi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Delaram Tamjid Shabestari
Biological Design Program, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publications- Hamed Arami
Materials Science and Engineering, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publications Layla Khalifehzadeh
Chemical Engineering, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publicationsMaryam Golshahi
Biological Design Program, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publicationsMostafa Sajjadi
Biological Design Program, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publicationsNaghmeh Shahraki
Biological Design Program, School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA
2 shared publications
Latest Publications
- Open Access
- 7 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0328374
Behavioral relevance of category selectivity revealed by human ECoG data
Object recognition is a crucial brain function that involves a complex interplay between various brain regions. However, the behavioral relevance of functional interactions between these regions remains largely unexplored. In this study, we examined the functional interactions between different brain regions during object recognition using intracranial electrocorticography (ECoG) recordings in subjects diagnosed with pharmacologically intractable epilepsy. We computed the phase locking value (PLV) between different brain areas and its category selectivity, and assessed its behavioral relevance by comparing correctly and incorrectly performed trials. Our results revealed that phase locking between brain regions varies across different object categories and that this variability significantly influences the perceptual behavior of subjects. Importantly, we found that the behavioral relevance of these interactions is spatially organized, with the high behaviorally relevant connections being longer for the frontal lobe and shorter for the occipital lobe. These findings underscore the unique roles of different brain areas in object recognition and pave the way for more nuanced explorations of the interplay between brain regions in object recognition and other cognitive functions.
- 7 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0328374
Open AccessBehavioral relevance of category selectivity revealed by human ECoG data
Object recognition is a crucial brain function that involves a complex interplay between various brain regions. However, the behavioral relevance of functional interactions between these regions remains largely unexplored. In this study, we examined the functional interactions between different brain regions during object recognition using intracranial electrocorticography (ECoG) recordings in subjects diagnosed with pharmacologically intractable epilepsy. We computed the phase locking value (PLV) between different brain areas and its category selectivity, and assessed its behavioral relevance by comparing correctly and incorrectly performed trials. Our results revealed that phase locking between brain regions varies across different object categories and that this variability significantly influences the perceptual behavior of subjects. Importantly, we found that the behavioral relevance of these interactions is spatially organized, with the high behaviorally relevant connections being longer for the frontal lobe and shorter for the occipital lobe. These findings underscore the unique roles of different brain areas in object recognition and pave the way for more nuanced explorations of the interplay between brain regions in object recognition and other cognitive functions.
- Open Access
- 25 July 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (33) , 26660-26672
Designing parylene coating for implantable brain–machine interfaces
This study investigates synergistic pre- and post-deposition treatments to systematically optimize adhesion and stability of parylene coatings for long-term implantable brain–machine interfaces.
- 25 July 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (33) , 26660-26672
Open AccessDesigning parylene coating for implantable brain–machine interfaces
This study investigates synergistic pre- and post-deposition treatments to systematically optimize adhesion and stability of parylene coatings for long-term implantable brain–machine interfaces.
- 12 July 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (19)
Ultra‐Sensitive Wireless Capacitive Nanocomposite‐Based Pressure Sensors for Health Monitoring
Wireless pressure sensing plays a crucial role in a wide range of applications, including robotics, wearables, and health monitoring. These sensors are of particular interest in healthcare, especially for monitoring physiological pressures such as intraocular, blood, bladder, and intracranial pressure (ICP), offering significant potential for clinical use. However, improving the sensitivity and in vivo performance of these sensors remains a key challenge. In this paper, a novel approach is introduced to enhance the sensitivity of wireless capacitive pressure sensors by utilizing a nanocomposite dielectric layer. Biocompatible zinc oxide (ZnO) nanoparticles are incorporated into styrene‐ethylene‐butylene‐styrene (SEBS) at different concentrations to fabricate a nanocomposite pyramid‐structured dielectric layer. Sensors with a 0.7%‐ZnO (v/v) nanocomposite dielectric layer exhibit a 4.3‐fold improvement in sensitivity compared to ones with a pure SEBS dielectric layer. The sensitivity of the fabricated sensors reaches a notably high value of 45 MHz mmHg⁻¹ within the pressure range of up to 25 mmHg. Additionally, a new pickup probe is developed that extends the wireless reading distance by 40% over conventional probes. Furthermore, in vivo studies are conducted, demonstrating reliable detection of ICP changes in murine models. This design enables wireless sensing without complex electronics, offering enhanced sensitivity, stability, and clinical potential.
- 12 July 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (19)
Ultra‐Sensitive Wireless Capacitive Nanocomposite‐Based Pressure Sensors for Health Monitoring
Wireless pressure sensing plays a crucial role in a wide range of applications, including robotics, wearables, and health monitoring. These sensors are of particular interest in healthcare, especially for monitoring physiological pressures such as intraocular, blood, bladder, and intracranial pressure (ICP), offering significant potential for clinical use. However, improving the sensitivity and in vivo performance of these sensors remains a key challenge. In this paper, a novel approach is introduced to enhance the sensitivity of wireless capacitive pressure sensors by utilizing a nanocomposite dielectric layer. Biocompatible zinc oxide (ZnO) nanoparticles are incorporated into styrene‐ethylene‐butylene‐styrene (SEBS) at different concentrations to fabricate a nanocomposite pyramid‐structured dielectric layer. Sensors with a 0.7%‐ZnO (v/v) nanocomposite dielectric layer exhibit a 4.3‐fold improvement in sensitivity compared to ones with a pure SEBS dielectric layer. The sensitivity of the fabricated sensors reaches a notably high value of 45 MHz mmHg⁻¹ within the pressure range of up to 25 mmHg. Additionally, a new pickup probe is developed that extends the wireless reading distance by 40% over conventional probes. Furthermore, in vivo studies are conducted, demonstrating reliable detection of ICP changes in murine models. This design enables wireless sensing without complex electronics, offering enhanced sensitivity, stability, and clinical potential.
- 27 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (1) , 780-786
Nonoverlapped Decoupling Technique With Flexible and Stretchable Dielectric-Loaded Coil Elements for Wearable Multichannel RF Coils
Radio frequency (RF) coils are RF front-end components in magnetic resonance imaging (MRI) system, which serve a significant role in determining image quality. This article introduces a novel decoupling technique using dielectric-loaded coils and evaluates their performance through bench tests, full-wave electromagnetic (EM) simulations, and MR imaging experiments at 9.4 T, thus at the Larmor frequency of 400 MHz. The proposed technique addresses the challenge of coupling between adjacent coil elements in an array and offers potential advantages for wearable multichannel RF coils. The results demonstrate comparable decoupling performance between a dielectric-loaded coil using a nonoverlapping method and a conventional coil with a 20% overlapped decoupling method. MR imaging experiments indicate improvements of 0.86%, 27.72%, and 8.94% in signal-to-noise ratio (SNR) at the near-surface region, center, and overall area encompassing both regions, respectively. Furthermore, the utilization of a dielectric-loaded coil resulted in an 89.8% enhancement in signal uniformity compared to the conventional overlapping technique. The proposed decoupling technique opens new opportunities for the development of flexible and stretchable coil structure toward wearable multichannel RF coils.
- 27 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (1) , 780-786
Nonoverlapped Decoupling Technique With Flexible and Stretchable Dielectric-Loaded Coil Elements for Wearable Multichannel RF Coils
Radio frequency (RF) coils are RF front-end components in magnetic resonance imaging (MRI) system, which serve a significant role in determining image quality. This article introduces a novel decoupling technique using dielectric-loaded coils and evaluates their performance through bench tests, full-wave electromagnetic (EM) simulations, and MR imaging experiments at 9.4 T, thus at the Larmor frequency of 400 MHz. The proposed technique addresses the challenge of coupling between adjacent coil elements in an array and offers potential advantages for wearable multichannel RF coils. The results demonstrate comparable decoupling performance between a dielectric-loaded coil using a nonoverlapping method and a conventional coil with a 20% overlapped decoupling method. MR imaging experiments indicate improvements of 0.86%, 27.72%, and 8.94% in signal-to-noise ratio (SNR) at the near-surface region, center, and overall area encompassing both regions, respectively. Furthermore, the utilization of a dielectric-loaded coil resulted in an 89.8% enhancement in signal uniformity compared to the conventional overlapping technique. The proposed decoupling technique opens new opportunities for the development of flexible and stretchable coil structure toward wearable multichannel RF coils.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (4) , 432-439
Flexible, Stretchable, and MR-Invisible Dielectric Material for Magnetic Resonance Imaging
Flexible, stretchable, and MR-invisible dielectric materials were studied to increase the local magnetic field (B 1 ) and signal-to-noise ratio (SNR) in magnetic resonance imaging. An electromagnetic simulation was performed with different dielectric constants and physical structures to measure the effects on the magnetic field (H) distribution and the specific absorption rate (SAR). After flexible and stretchable dielectric pads composed of silicon carbide (SiC)- and barium titanate (BaTiO 3 )-based polymer mixtures were fabricated, MR imaging tests with two isotropic phantoms and an oxtail sample were performed in a preclinical 7 T scanner (BioSpec scanner, Bruker). The B 1 field intensities and SNR were compared with a reference image. Also, additional noise and image artifacts were evaluated. Simulation results show that wrapping an object with a dielectric material is the most effective method to increase the intensity and uniformity of the H field. The results of MR imaging consistently show a higher B 1 field intensity and SNR when utilizing dielectric materials. An improvement of 25.78% and 18.27% in SNR was observed when SiC- and BaTiO 3 -based dielectric pads were wrapped around an oxtail, respectively. In this work, the first stretchable dielectric materials with MR-invisibility were developed, and their performance was demonstrated with 7 T MR imaging.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (4) , 432-439
Flexible, Stretchable, and MR-Invisible Dielectric Material for Magnetic Resonance Imaging
Flexible, stretchable, and MR-invisible dielectric materials were studied to increase the local magnetic field (B 1 ) and signal-to-noise ratio (SNR) in magnetic resonance imaging. An electromagnetic simulation was performed with different dielectric constants and physical structures to measure the effects on the magnetic field (H) distribution and the specific absorption rate (SAR). After flexible and stretchable dielectric pads composed of silicon carbide (SiC)- and barium titanate (BaTiO 3 )-based polymer mixtures were fabricated, MR imaging tests with two isotropic phantoms and an oxtail sample were performed in a preclinical 7 T scanner (BioSpec scanner, Bruker). The B 1 field intensities and SNR were compared with a reference image. Also, additional noise and image artifacts were evaluated. Simulation results show that wrapping an object with a dielectric material is the most effective method to increase the intensity and uniformity of the H field. The results of MR imaging consistently show a higher B 1 field intensity and SNR when utilizing dielectric materials. An improvement of 25.78% and 18.27% in SNR was observed when SiC- and BaTiO 3 -based dielectric pads were wrapped around an oxtail, respectively. In this work, the first stretchable dielectric materials with MR-invisibility were developed, and their performance was demonstrated with 7 T MR imaging.