Flexible, Stretchable, and MR-Invisible Dielectric Material for Magnetic Resonance Imaging
- 16 October 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (4) , 432-439
Abstract
Flexible, stretchable, and MR-invisible dielectric materials were studied to increase the local magnetic field (B 1 ) and signal-to-noise ratio (SNR) in magnetic resonance imaging. An electromagnetic simulation was performed with different dielectric constants and physical structures to measure the effects on the magnetic field (H) distribution and the specific absorption rate (SAR). After flexible and stretchable dielectric pads composed of silicon carbide (SiC)- and barium titanate (BaTiO 3 )-based polymer mixtures were fabricated, MR imaging tests with two isotropic phantoms and an oxtail sample were performed in a preclinical 7 T scanner (BioSpec scanner, Bruker). The B 1 field intensities and SNR were compared with a reference image. Also, additional noise and image artifacts were evaluated. Simulation results show that wrapping an object with a dielectric material is the most effective method to increase the intensity and uniformity of the H field. The results of MR imaging consistently show a higher B 1 field intensity and SNR when utilizing dielectric materials. An improvement of 25.78% and 18.27% in SNR was observed when SiC- and BaTiO 3 -based dielectric pads were wrapped around an oxtail, respectively. In this work, the first stretchable dielectric materials with MR-invisibility were developed, and their performance was demonstrated with 7 T MR imaging.Keywords
This publication has 56 references indexed in Scilit:
- Dielectric materials in magnetic resonanceConcepts in Magnetic Resonance Part A, 2011
- Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjectsMagnetic Resonance in Medicine, 2011
- Reducing SAR and enhancing cerebral signal‐to‐noise ratio with high permittivity padding at 3 TMagnetic Resonance in Medicine, 2010
- Molecular Weight Dependence of Glassy Dynamics in Linear Polymers RevisitedMacromolecules, 2008
- Specific absorption rate studies of the parallel transmission of inner‐volume excitations at 7TJournal of Magnetic Resonance Imaging, 2008
- Comparison of Different Cardiac MRI Sequences at 1.5 T/3.0 T with Respect to Signal-to-Noise and Contrast-to-Noise Ratios - Initial ExperienceRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Rheological and dielectric studies of aggregation of barium titanate particles suspended in polydimethylsiloxanePolymer, 2000
- Homogeneous Tissue Model Estimates of RF Power Deposition in Human NMR StudiesAnnals of the New York Academy of Sciences, 1992