Thomas Lehmeier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Lehmeier has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Martin März
Institute for Power Electronics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 90429 Nuremberg, Germany
2 shared publications - Yan Zhou
Institute of Power Electronics, Friedrich-Alexander-Universitt Erlangen-Nrnberg, Nrnberg, Germany
2 shared publications - Adrian Amler
Institute of Power Electronics at Friedrich-Alexander-Universitt Erlangen-Nrnberg, Nrnberg, Germany
1 shared publication
Latest Publications
- Open Access
- 12 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 5303-5318
Four-Level TCM-Operated Inverter With Full Soft-Switching Capability Using a Hybrid Si+SiC Configuration
Triangular current mode (TCM) modulation is a promising technique for achieving zero-voltage switching (ZVS) in dc–ac power inverters, which already inherently offers a high output voltage quality without a sine-wave filter. Despite slightly higher conduction losses than hard-switched inverters using conventional pulsewidth modulation (PWM), TCM-operated inverters achieve outstanding efficiency by significantly reducing switching losses, especially under low-load conditions. However, TCM faces the challenge of a wide variation in switching frequency throughout the fundamental cycle, which is often managed by suspending TCM operation near zero-crossings to prevent exceeding frequency limits. This article introduces a novel multilevel TCM inverter topology featuring two cascaded stages and an asymmetrically subdivided dc-link. For optimized cost and performance, the two stages employ a hybrid configuration using silicon carbide (SiC) mosfets in the high-frequency stage and Si IGBTs in the low-frequency stage. This design reduces the voltage stress on all power semiconductors and ensures full soft-switching capability even near voltage zero-crossings without excessive switching frequency fluctuations. The effectiveness of the presented topology is maximized when paired with a control algorithm that ensures continuous soft-switching across all devices and manages the necessary voltage control for the subdivided dc-link. A single-phase 2 kW hardware demonstrator with a 1.5 kV dc-link was designed and implemented to validate this concept, incorporating the proposed control algorithm. The demonstrator achieves a peak efficiency of more than 98.6% at nominal load, demonstrating the effectiveness of the full soft-switching capability provided by the new topology.
- 12 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 5303-5318
Open AccessFour-Level TCM-Operated Inverter With Full Soft-Switching Capability Using a Hybrid Si+SiC Configuration
Triangular current mode (TCM) modulation is a promising technique for achieving zero-voltage switching (ZVS) in dc–ac power inverters, which already inherently offers a high output voltage quality without a sine-wave filter. Despite slightly higher conduction losses than hard-switched inverters using conventional pulsewidth modulation (PWM), TCM-operated inverters achieve outstanding efficiency by significantly reducing switching losses, especially under low-load conditions. However, TCM faces the challenge of a wide variation in switching frequency throughout the fundamental cycle, which is often managed by suspending TCM operation near zero-crossings to prevent exceeding frequency limits. This article introduces a novel multilevel TCM inverter topology featuring two cascaded stages and an asymmetrically subdivided dc-link. For optimized cost and performance, the two stages employ a hybrid configuration using silicon carbide (SiC) mosfets in the high-frequency stage and Si IGBTs in the low-frequency stage. This design reduces the voltage stress on all power semiconductors and ensures full soft-switching capability even near voltage zero-crossings without excessive switching frequency fluctuations. The effectiveness of the presented topology is maximized when paired with a control algorithm that ensures continuous soft-switching across all devices and manages the necessary voltage control for the subdivided dc-link. A single-phase 2 kW hardware demonstrator with a 1.5 kV dc-link was designed and implemented to validate this concept, incorporating the proposed control algorithm. The demonstrator achieves a peak efficiency of more than 98.6% at nominal load, demonstrating the effectiveness of the full soft-switching capability provided by the new topology.
- Open Access
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2505-2521
Three-Phase ARCP Inverter Using Soft-Switching With a Single Shared Inductor
Soft-switching in power inverters for drive and grid applications can both enhance the efficiency by reducing switching losses and improve electromagnetic interference (EMI) due to lower switching speeds with their associated $\mathrm{d}v/\mathrm{d}t$ . An advantageous topology is the well-known auxiliary resonant commutated pole (ARCP) inverter. The development of such power electronic inverters often focuses on reducing weight, volume, and cost. Considering a three-phase ARCP system, this article presents a novel single shared inductor $(\mathrm{S}^{2}\mathrm{I})$ -ARCP approach to reduce the passive component count in the auxiliary circuit from three to one. The simultaneous use of the shared inductor by more than one phase must be detected and avoided by the control algorithm. A frequency analysis of such occurrences is performed, and a method for avoiding them by shifting the switching edges is presented. The proposed $\mathrm{S}^{2}\mathrm{I}$ -ARCP topology together with an appropriate control algorithm is implemented and validated at 10 kW with an 800 V dc-link. Efficiency measurement results indicated a significant loss reduction under soft-switching operation by more than 38% compared with hard-switching, with a peak efficiency value of 99.58%. It is demonstrated that a mere adjustment in the control signal generation can save two resonant inductors without significant disadvantages.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2505-2521
Open AccessThree-Phase ARCP Inverter Using Soft-Switching With a Single Shared Inductor
Soft-switching in power inverters for drive and grid applications can both enhance the efficiency by reducing switching losses and improve electromagnetic interference (EMI) due to lower switching speeds with their associated $\mathrm{d}v/\mathrm{d}t$ . An advantageous topology is the well-known auxiliary resonant commutated pole (ARCP) inverter. The development of such power electronic inverters often focuses on reducing weight, volume, and cost. Considering a three-phase ARCP system, this article presents a novel single shared inductor $(\mathrm{S}^{2}\mathrm{I})$ -ARCP approach to reduce the passive component count in the auxiliary circuit from three to one. The simultaneous use of the shared inductor by more than one phase must be detected and avoided by the control algorithm. A frequency analysis of such occurrences is performed, and a method for avoiding them by shifting the switching edges is presented. The proposed $\mathrm{S}^{2}\mathrm{I}$ -ARCP topology together with an appropriate control algorithm is implemented and validated at 10 kW with an 800 V dc-link. Efficiency measurement results indicated a significant loss reduction under soft-switching operation by more than 38% compared with hard-switching, with a peak efficiency value of 99.58%. It is demonstrated that a mere adjustment in the control signal generation can save two resonant inductors without significant disadvantages.