Ze Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ze Cai has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hang Gao
Beihang University
2 shared publications - Kai Zhang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications - Linlin Yuan
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
2 shared publications - Wenfeng Fan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
2 shared publications - Hongyu Pei
Institute of Large-scale Scientific Facility and Center for Zero Magnetic Field Science and the School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
1 shared publication
Latest Publications
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.
- Open Access
Analysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
Open AccessAnalysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Real-Time In Situ Quantum Feedback Control of Electron Spin in Atomic Spin Gyroscopes
The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Real-Time In Situ Quantum Feedback Control of Electron Spin in Atomic Spin Gyroscopes
The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.