Orhan Ayas
Orhan Ayas has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alaeddin Acar
Department of Neurosurgery, Kulu State Hospital, Konya, Turkey
2 shared publications - Abuzer Uludağ
Orthopaedics, Adiyaman University Faculty of Medicine, Adiyaman, TUR
1 shared publication - Hacı Bayram Tosun
Orthopaedics, Istanbul Medipol University, Istanbul, TUR
1 shared publication - Hüseyin Kürüm
Elazığ Fethi Sekin Training and Research Hospital, Elazığ, Turkey
1 shared publication - Oğuz Kaya
Department of Orthopedics and Traumatology, Elazig Fethi Sekin City Hospital, Elazig 23280, Turkey
1 shared publication - Sancar Serbest
Department of Orthopaedics and Traumatology, Kırıkkale University Faculty of Medicine Hospital, Kırıkkale, Türkiye
1 shared publication
Latest Publications
- 1 July 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (7) , e172
Letter to the Editor Regarding “Proton Pump Inhibitors Are Associated With Increased Risk of Site-Specific Nonunion After Open Reduction Internal Fixation”
An abstract is unavailable. This article is available as a PDF only.
- 1 July 2026
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 40 (7) , e172
Letter to the Editor Regarding “Proton Pump Inhibitors Are Associated With Increased Risk of Site-Specific Nonunion After Open Reduction Internal Fixation”
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 17 March 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10 (1) , e90242
Critical Limitations in Comparing ChatGPT and DeepSeek for Orthopedic Assessment
We read with great interest the study by Anusitviwat et al [1], which compared the performance of ChatGPT and DeepSeek in orthopedic examinations. While the study provides timely insights into the utility of Large Language Models (LLMs) in medical education, we identified specific methodological and terminological limitations that warrant clarification to ensure the validity and reproducibility of the findings. Misinterpretation of Reliability Statistics The authors state that the "interrater reliability between the two LLMs" was evaluated using the Cohen κ coefficient [1]. Mathematically, measuring the agreement between two independent raters (inter-rater) yields a single coefficient. However, the results report two separate values: κ=0.81 for ChatGPT and κ=0.78 for DeepSeek [1]. This finding, combined with the methodology stating questions were input on "separate days [1], indicates that the study actually measured intra-model consistency (test-retest reliability) rather than the agreement between the models. Labeling internal consistency as "interrater reliability" is terminologically inaccurate and misrepresents the statistical relationship between the two models. Linguistic Ambiguity and Generalizability The manuscript does not specify the language of the input MCQs (Thai or English) used in the assessments. This omission is critical, as the impact of input language on LLM performance is well-documented. For instance, Noda et al (2024) [2] demonstrated that GPT-4V's accuracy on the Japanese Otolaryngology Board Examination significantly improved from 24.7% (Japanese input) to 47.3% when translated into English. This finding underscores that models optimized for English exhibit distinct performance disparities in non-English languages. Without clarifying whether the assessments were administered in the local language or English, it is impossible to determine if the reported accuracy gap between ChatGPT (80.4%) and DeepSeek (74.2%) stems from medical reasoning capabilities or linguistic processing proficiency. Reproducibility and Interface Transparency The methodology reports the use of "Reason" and "DeepThink" functions but does not explicitly state whether the models were accessed via Web User Interfaces (UI) or Application Programming Interfaces (API) [1]. This distinction is vital for reproducibility. Web UIs are subject to opaque updates and lack the stability of controlled API environments. Without defining the access method and the specific prompt structures used, the experimental conditions cannot be replicated. Risk of Data Contamination The authors note that the MCQs "have been used in orthopedic examinations for more than 5 years". This longevity significantly increases the risk of data contamination, as older items likely exist in public repositories within LLM training corpora, potentially conflating memorization with reasoning. To ensure validity, recent benchmarks employ private datasets (Busch et al [3]) or questions post-dating the model’s training cut-off (Noda et al [2]). The absence of such controls in this study undermines the internal validity of the comparison Data Reporting Discrepancy Finally, we noted a minor discrepancy in Table 2. In the "Pelvic and spine injury" category (n=19), the accuracy for the Reason function is listed as 16 (68.8%) [1]. Mathematically, 16 out of 19 corresponds to approximately 84.2%, not 68.8%. We respectfully invite the authors to clarify this value to ensure the precision of the tabulated data.
- 17 March 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10 (1) , e90242
Open AccessCritical Limitations in Comparing ChatGPT and DeepSeek for Orthopedic Assessment
We read with great interest the study by Anusitviwat et al [1], which compared the performance of ChatGPT and DeepSeek in orthopedic examinations. While the study provides timely insights into the utility of Large Language Models (LLMs) in medical education, we identified specific methodological and terminological limitations that warrant clarification to ensure the validity and reproducibility of the findings. Misinterpretation of Reliability Statistics The authors state that the "interrater reliability between the two LLMs" was evaluated using the Cohen κ coefficient [1]. Mathematically, measuring the agreement between two independent raters (inter-rater) yields a single coefficient. However, the results report two separate values: κ=0.81 for ChatGPT and κ=0.78 for DeepSeek [1]. This finding, combined with the methodology stating questions were input on "separate days [1], indicates that the study actually measured intra-model consistency (test-retest reliability) rather than the agreement between the models. Labeling internal consistency as "interrater reliability" is terminologically inaccurate and misrepresents the statistical relationship between the two models. Linguistic Ambiguity and Generalizability The manuscript does not specify the language of the input MCQs (Thai or English) used in the assessments. This omission is critical, as the impact of input language on LLM performance is well-documented. For instance, Noda et al (2024) [2] demonstrated that GPT-4V's accuracy on the Japanese Otolaryngology Board Examination significantly improved from 24.7% (Japanese input) to 47.3% when translated into English. This finding underscores that models optimized for English exhibit distinct performance disparities in non-English languages. Without clarifying whether the assessments were administered in the local language or English, it is impossible to determine if the reported accuracy gap between ChatGPT (80.4%) and DeepSeek (74.2%) stems from medical reasoning capabilities or linguistic processing proficiency. Reproducibility and Interface Transparency The methodology reports the use of "Reason" and "DeepThink" functions but does not explicitly state whether the models were accessed via Web User Interfaces (UI) or Application Programming Interfaces (API) [1]. This distinction is vital for reproducibility. Web UIs are subject to opaque updates and lack the stability of controlled API environments. Without defining the access method and the specific prompt structures used, the experimental conditions cannot be replicated. Risk of Data Contamination The authors note that the MCQs "have been used in orthopedic examinations for more than 5 years". This longevity significantly increases the risk of data contamination, as older items likely exist in public repositories within LLM training corpora, potentially conflating memorization with reasoning. To ensure validity, recent benchmarks employ private datasets (Busch et al [3]) or questions post-dating the model’s training cut-off (Noda et al [2]). The absence of such controls in this study undermines the internal validity of the comparison Data Reporting Discrepancy Finally, we noted a minor discrepancy in Table 2. In the "Pelvic and spine injury" category (n=19), the accuracy for the Reason function is listed as 16 (68.8%) [1]. Mathematically, 16 out of 19 corresponds to approximately 84.2%, not 68.8%. We respectfully invite the authors to clarify this value to ensure the precision of the tabulated data.
- Open Access
- 14 September 2023
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 29, e942154-1-e942154-11
Comparative Study of Minimally Invasive Plate Osteosynthesis (MIPO) and Intramedullary Nailing (IMN) for Treating Extraarticular Distal Tibial Fractures: Clinical and Radiological Outcomes
Treatment of extra-articular distal tibial fractures is problematic owing to limited soft tissue cover, poor vascularity of the location, and adjacency to the ankle, and thus continues to be controversial. This study aimed to compare clinical and radiological outcomes in 69 patients with extra-articular distal tibia fractures treated with minimally invasive plate osteosynthesis (MIPO) and an interlocking intramedullary nail (IMN). Sixty-nine patients, with mean of age 39.8±18.3 years, were retrospectively evaluated. Thirty-five patients were treated with IMN, and 34 patients were treated with MIPO. Clinical and radiological outcomes were evaluated. The average follow-up was 13.3±6 months and union time was 16.2±5.4 weeks. Nonunion was observed in only 4.3% of patients treated with MIPO (P=0.114). Non-acceptable malalignment of extremity was observed in 4.3% of patients with IMN and 7.2% of patients with MIPO. There were no significant differences in union time, nonunion, surgical timing, operating time, malalignment, and complications between groups (P>0.05). The mean American Orthopaedic Foot and Ankle Society (AOFAS) surgery score was 95.8±5 in IMN and 91.9±14.3 in MIPO. AOFAS, Tenny-Wiss radiological, and Ovadia-Beals clinical scores were better in IMN than MIPO (P=0.019, P=0.03, P=0.02, respectively). Mean time of full weight-bearing and of return to daily life with IMN was significantly shorter than with MIPO (P<0.001). IMN and MIPO methods are reliable and effective methods with similar good results in the surgical treatment of extra-articular distal tibia fractures. However, IMN may be preferred for early full weight-bearing and early return to daily life (P<0.001).
- 14 September 2023
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 29, e942154-1-e942154-11
Open AccessComparative Study of Minimally Invasive Plate Osteosynthesis (MIPO) and Intramedullary Nailing (IMN) for Treating Extraarticular Distal Tibial Fractures: Clinical and Radiological Outcomes
Treatment of extra-articular distal tibial fractures is problematic owing to limited soft tissue cover, poor vascularity of the location, and adjacency to the ankle, and thus continues to be controversial. This study aimed to compare clinical and radiological outcomes in 69 patients with extra-articular distal tibia fractures treated with minimally invasive plate osteosynthesis (MIPO) and an interlocking intramedullary nail (IMN). Sixty-nine patients, with mean of age 39.8±18.3 years, were retrospectively evaluated. Thirty-five patients were treated with IMN, and 34 patients were treated with MIPO. Clinical and radiological outcomes were evaluated. The average follow-up was 13.3±6 months and union time was 16.2±5.4 weeks. Nonunion was observed in only 4.3% of patients treated with MIPO (P=0.114). Non-acceptable malalignment of extremity was observed in 4.3% of patients with IMN and 7.2% of patients with MIPO. There were no significant differences in union time, nonunion, surgical timing, operating time, malalignment, and complications between groups (P>0.05). The mean American Orthopaedic Foot and Ankle Society (AOFAS) surgery score was 95.8±5 in IMN and 91.9±14.3 in MIPO. AOFAS, Tenny-Wiss radiological, and Ovadia-Beals clinical scores were better in IMN than MIPO (P=0.019, P=0.03, P=0.02, respectively). Mean time of full weight-bearing and of return to daily life with IMN was significantly shorter than with MIPO (P<0.001). IMN and MIPO methods are reliable and effective methods with similar good results in the surgical treatment of extra-articular distal tibia fractures. However, IMN may be preferred for early full weight-bearing and early return to daily life (P<0.001).