Latest Publications

  • Open Access

    Long‐Term Performance and Bulk‐Isotope Effects in Methane Clumped‐Isotope Measurements Using a 253 Ultra HR‐IRMS

    by Naizhong Zhang, Alexis Gilbert, Mayuko Nakagawa, Jakub Surma, Jan G. C. Meissner, Joachim Mohn, Stefano M. Bernasconi, Yuichiro Ueno, Naohiro Yoshida

    Rationale: Changes in instrument condition over time may affect methane clumped‐isotope measurements, requiring long‐term monitoring of calibration performance. Whether the 253 Ultra calibration framework remains valid over multiyear operation and applicable across natural bulk‐isotope compositions, particularly to low‐δD methane with weak 12 CH 2 D 2 signals, has not been systematically evaluated. Methods: Long‐term performance of the Science Tokyo 253 Ultra was evaluated from 2019 to 2026 using reference‐gas zero tests, repeated working‐gas measurements, and independently prepared equilibrated methane gases. Equilibrated gases with different δ 13 C and δD compositions were used to test for possible bulk‐isotope dependence in Δ 13 CH₃D and Δ 12 CH 2 D 2 measurements. External consistency was assessed using nine shared methane gases measured across seven laboratories with 253 Ultra HR‐IRMS, Panorama HR‐IRMS, and mid‐infrared laser spectroscopy. Results: Reference and working gases showed no temporal drift, and equilibrated gases measured from 2021 to 2026 remained consistent with the calibration framework established in 2020. No systematic dependence of Δ 13 CH₃D or Δ 12 CH 2 D 2 on either δ 13 C or δD was resolved, including for equilibrium gases with δD values as low as −335‰. Science Tokyo measurements were generally consistent with results from other laboratories across a wide range of bulk‐isotope compositions and nonequilibrium clumped‐isotope signatures. Conclusions: The calibration framework established for methane clumped‐isotope measurements with the Science Tokyo 253 Ultra HR‐IRMS remained stable and applicable over multiple analytical campaigns. Validation measurements and interlaboratory comparisons demonstrated consistent results across a broad range of methane bulk‐isotope compositions, without the need for campaign‐specific or additional bulk‐isotope–dependent corrections, with δD values extending down to −335‰.

  • Triple oxygen isotopes of modern terrestrial mammalian tooth enamel – New implications for paleoenvironmental and physiological research

    by Dingsu Feng, Jakub Surma, Thomas Tütken, Niklas Löffler, Gisa Heinemann, Gert Tröster, Fabian Zahnow, Daniel Herwartz, Andreas Pack


  • Open Access

    A Dual Inlet System for Laser Spectroscopy of Triple Oxygen Isotopes in Carbonate‐Derived and Air CO2

    by David Bajnai, Andreas Pack, Fiorella Arduin Rode, Malte Seefeld, Jakub Surma, Tommaso Di Rocco

    Analyzing the triple oxygen isotope (Δ′17O) composition of carbonates and air CO2 can provide valuable information about Earth system processes. However, accurately measuring the abundance of the rare 17O‐bearing CO2 isotopologue using isotope ratio mass spectrometry presents significant challenges. Consequently, alternative approaches, such as laser spectroscopy, have been developed. Here, we describe an adaptable dual inlet system for a tunable infrared laser direct absorption spectrometer (TILDAS) that maintains stable instrumental conditions for subsequent sample and reference measurements. We report ∆′17O measurements on three types of samples: reference CO2, CO2 derived from the acid digestion of carbonates, and air CO2. The external repeatability (±1σ) for reference‐sample‐reference bracketing measurements is generally better than ±10 ppm, close to the average internal error of ±6 ppm. Our results demonstrate that laser spectroscopy is a capable technique for measuring triple oxygen isotopes with the precision required to resolve variations in the ∆′17O values of air CO2 and to use the ∆′17O of carbonates for paleothermometry.