Valeriy Plis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Valeriy Plis has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrii Boiko
Odesa Polytechnic National University
1 shared publication - Daniil Tokarchuk
Odesa Polytechnic National University
1 shared publication - Mykhailo Shabovta1 shared publication
Odessa National Polytechnic University
1 shared publication- Pavlo Brem
Odesa Polytechnic National University
1 shared publication - Yevgen Sokolov
Odesa Polytechnic National University
1 shared publication
Latest Publications
- Open Access
- 7 May 2026
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 2(96),p. 18-29
МАТЕМАТИЧНЕ МОДЕЛЮВАННЯ АСИНХРОННОГО ЕЛЕКТРОПРИВОДУ НАМОТУВАЛЬНОГО ПРИСТРОЮ
У статті розглянуто процес математичного моделювання асинхронного електропривода намотувального пристрою, що є ключовою складовою технологічної лінії з виробництва кабельної продукції. Основну увагу приділено особливостям роботи електропривода в умовах змінної динаміки системи, пов’язаної зі зміною моменту інерції, радіуса намотки та навантаження протягом робочого циклу. Окреслено необхідність підтримання стабільного натягу кабелю та синхронізації швидкості намотування з іншими етапами виробничої лінії, що визначає якість та надійність готової продукції. Запропоновано узагальнену математичну модель електромеханічної системи, побудовану на основі рівнянь у координатах α–β з урахуванням принципів векторного керування та сучасних підходів до регулювання частоти й моменту. Модель дозволяє врахувати взаємодію електричних і механічних параметрів системи, що забезпечує достовірне відтворення реальних режимів роботи та створює основу для подальшої оптимізації системи керування. У ході дослідження отримано перехідні процеси пуску електропривода, зміни режимів у момент переходу між шарами намотки, а також поведінку системи протягом усього циклу роботи. Проведено аналіз впливу змінних навантажень та параметрів барабана на швидкість, момент і струми статора. Побудовані графіки зміни основних параметрів системи у часі дали змогу оцінити динамічні властивості привода. Показано, що застосування адаптивного регулятора швидкості дозволяє підтримувати стабільні робочі характеристики, мінімізувати перевантаження та забезпечити енергоефективність функціонування системи. Результати моделювання підтверджують доцільність використання розробленої моделі для практичних рішень у високоточних технологічних процесах, де необхідний сталий контроль натягу кабелю. Водночас підкреслюється можливість інтеграції моделі у сучасні цифрові системи керування, що відкриває перспективи для модернізації існуючих виробничих ліній та створення нових енергоефективних рішень.
- 7 May 2026
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 2(96),p. 18-29
Open AccessМАТЕМАТИЧНЕ МОДЕЛЮВАННЯ АСИНХРОННОГО ЕЛЕКТРОПРИВОДУ НАМОТУВАЛЬНОГО ПРИСТРОЮ
У статті розглянуто процес математичного моделювання асинхронного електропривода намотувального пристрою, що є ключовою складовою технологічної лінії з виробництва кабельної продукції. Основну увагу приділено особливостям роботи електропривода в умовах змінної динаміки системи, пов’язаної зі зміною моменту інерції, радіуса намотки та навантаження протягом робочого циклу. Окреслено необхідність підтримання стабільного натягу кабелю та синхронізації швидкості намотування з іншими етапами виробничої лінії, що визначає якість та надійність готової продукції. Запропоновано узагальнену математичну модель електромеханічної системи, побудовану на основі рівнянь у координатах α–β з урахуванням принципів векторного керування та сучасних підходів до регулювання частоти й моменту. Модель дозволяє врахувати взаємодію електричних і механічних параметрів системи, що забезпечує достовірне відтворення реальних режимів роботи та створює основу для подальшої оптимізації системи керування. У ході дослідження отримано перехідні процеси пуску електропривода, зміни режимів у момент переходу між шарами намотки, а також поведінку системи протягом усього циклу роботи. Проведено аналіз впливу змінних навантажень та параметрів барабана на швидкість, момент і струми статора. Побудовані графіки зміни основних параметрів системи у часі дали змогу оцінити динамічні властивості привода. Показано, що застосування адаптивного регулятора швидкості дозволяє підтримувати стабільні робочі характеристики, мінімізувати перевантаження та забезпечити енергоефективність функціонування системи. Результати моделювання підтверджують доцільність використання розробленої моделі для практичних рішень у високоточних технологічних процесах, де необхідний сталий контроль натягу кабелю. Водночас підкреслюється можливість інтеграції моделі у сучасні цифрові системи керування, що відкриває перспективи для модернізації існуючих виробничих ліній та створення нових енергоефективних рішень.
- 1 January 2026
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- p. 14-25
Simplified Modeling of a Thyristor Asynchronous Electric Drive
The paper develops a simplified model of an asynchronous electric drive with a thyristor voltage converter, focused on the balance between calculation accuracy and computational efficiency. The output voltage of the converter is represented by a set of harmonics supplied to the asynchronous motor, which eliminates the need for detailed modeling of the switching processes of each switch. This approach allows using both a full motor model and an approximate one, preserving the symmetry of the machine and the main characteristics of the studied modes. Special attention is paid to modeling the supply voltage source and developing methods for determining the stator current phase. Two approaches are considered: determining the equivalent phase by the active and reactive components of the equivalent resistance and calculating the instantaneous phase by the projections of phase currents and voltages. Structural diagrams of models for calculating static characteristics and dynamic modes, including starting, reversing, and changing the control angles of the switches, are presented. The proposed model allows you to study the dynamics of currents and torques during polyharmonic power supply, taking into account the influence of higher harmonics and phase shifts, and also integrates with automation systems. The results of the work demonstrate that simplified models of an asynchronous thyristor electric drive can be an effective tool for both analysis and syn-thesis of thyristor electromechanical systems. Keywords: asynchronous electric drive, electromechanical system, thyristor converter, modeling, simplified model, critical energy infrastructure, external negative impacts, hierarchical modeling.
- 1 January 2026
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- p. 14-25
Simplified Modeling of a Thyristor Asynchronous Electric Drive
The paper develops a simplified model of an asynchronous electric drive with a thyristor voltage converter, focused on the balance between calculation accuracy and computational efficiency. The output voltage of the converter is represented by a set of harmonics supplied to the asynchronous motor, which eliminates the need for detailed modeling of the switching processes of each switch. This approach allows using both a full motor model and an approximate one, preserving the symmetry of the machine and the main characteristics of the studied modes. Special attention is paid to modeling the supply voltage source and developing methods for determining the stator current phase. Two approaches are considered: determining the equivalent phase by the active and reactive components of the equivalent resistance and calculating the instantaneous phase by the projections of phase currents and voltages. Structural diagrams of models for calculating static characteristics and dynamic modes, including starting, reversing, and changing the control angles of the switches, are presented. The proposed model allows you to study the dynamics of currents and torques during polyharmonic power supply, taking into account the influence of higher harmonics and phase shifts, and also integrates with automation systems. The results of the work demonstrate that simplified models of an asynchronous thyristor electric drive can be an effective tool for both analysis and syn-thesis of thyristor electromechanical systems. Keywords: asynchronous electric drive, electromechanical system, thyristor converter, modeling, simplified model, critical energy infrastructure, external negative impacts, hierarchical modeling.
- Open Access
- 29 January 2024
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 4(87),p. 197-208
ТЕСТУВАННЯ МІКРОПРОЦЕСОРНИХ ТЕРМІНАЛІВ РЕЛЕЙНОГО ЗАХИСТУ В РОЗРАХУНКОВИХ РЕЖИМАХ
Цифровізація у електроенергетиці є невід’ємною частиною цифрової економіки. Не менш важливим завданням при підготовці фахівців електротехнічних спеціальностей є цифровізація освітнього процесу. Для її вирішення потрібне впровадження програмних комплексів, із застосуванням яких майбутні фахівці зможуть моделювати об’єкти електроенергетичної системи, але на більш комфортній та безпечній платформі. Необхідно проведення дослідження функціональних можливостей мікропроцесорних терміналів релейного захисту та автоматизації шляхом їх комп’ютерного моделювання з урахуванням поведінки захистів у характерних для елемента, що захищається режимах роботи. У роботі розглянуто питання моделювання цифрового пристрою релейного захисту на прикладі струмої відсічки для асинхронного електродвигуна напругою 6 кВ при трифазному короткому замиканні з можливістю перегляду результатів моделювання. Синтезовані: імітаційна модель схеми струмової відсічки асинхронного двигуна; субсистема, що дозволяє моделювати коротке замикання асинхронного двигуна при регульованих уставках струму і часу. У ході проведення експерименту на моделі є можливість розрахувати параметри спрацьовування захистів мікропроцесорного терміналу і перевірити правильність роботи захистів, а також вивчення нормальних та аварійних режимів роботи об’єкта, що захищається. Оцінка результатів моделювання дозволяє забезпечити налаштування мікропроцесорного захисту. Спільне використання розробленої моделі та експериментального стенду дозволяють досягти найповнішого дослідження функціональних можливостей мікропроцесорних пристроїв релейного захисту. Порівняння результатів експериментів з моделями дозволяє стверджувати, що розбіжності між розрахунковими та експериментальними даними не перевищують 4–6 %, в статичних режимах, та 12–14 %, в динамічних режимах.
- 29 January 2024
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 4(87),p. 197-208
Open AccessТЕСТУВАННЯ МІКРОПРОЦЕСОРНИХ ТЕРМІНАЛІВ РЕЛЕЙНОГО ЗАХИСТУ В РОЗРАХУНКОВИХ РЕЖИМАХ
Цифровізація у електроенергетиці є невід’ємною частиною цифрової економіки. Не менш важливим завданням при підготовці фахівців електротехнічних спеціальностей є цифровізація освітнього процесу. Для її вирішення потрібне впровадження програмних комплексів, із застосуванням яких майбутні фахівці зможуть моделювати об’єкти електроенергетичної системи, але на більш комфортній та безпечній платформі. Необхідно проведення дослідження функціональних можливостей мікропроцесорних терміналів релейного захисту та автоматизації шляхом їх комп’ютерного моделювання з урахуванням поведінки захистів у характерних для елемента, що захищається режимах роботи. У роботі розглянуто питання моделювання цифрового пристрою релейного захисту на прикладі струмої відсічки для асинхронного електродвигуна напругою 6 кВ при трифазному короткому замиканні з можливістю перегляду результатів моделювання. Синтезовані: імітаційна модель схеми струмової відсічки асинхронного двигуна; субсистема, що дозволяє моделювати коротке замикання асинхронного двигуна при регульованих уставках струму і часу. У ході проведення експерименту на моделі є можливість розрахувати параметри спрацьовування захистів мікропроцесорного терміналу і перевірити правильність роботи захистів, а також вивчення нормальних та аварійних режимів роботи об’єкта, що захищається. Оцінка результатів моделювання дозволяє забезпечити налаштування мікропроцесорного захисту. Спільне використання розробленої моделі та експериментального стенду дозволяють досягти найповнішого дослідження функціональних можливостей мікропроцесорних пристроїв релейного захисту. Порівняння результатів експериментів з моделями дозволяє стверджувати, що розбіжності між розрахунковими та експериментальними даними не перевищують 4–6 %, в статичних режимах, та 12–14 %, в динамічних режимах.
- 30 June 2023
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- Vol. 37 (113) , 17-25
RESEARCH OF DIGITAL PROTECTION TERMINALS
Due to the development of technologies, the widely used electromechanical relays in the electric power industry have been replaced by multifunctional digital relay protection terminals. For the training of students and electrical personnel of enterprises, new approaches to the creation of experimental stands are needed, which will allow us to study the features of the use of digital protection and fully reveal their capabilities. The purpose of the work is to improve the quality of the knowledge and practical skills received by students in working with digital protection blocks. To achieve the goal, a specialized laboratory stand for testing digital security terminals has been developed. The stand consists of a mathematical model of the protected object and hardware, due to which the model mode parameters are converted into physical signals and fed in real time to a real digital device. The study of the protected element is provided in the characteristic modes of its operation close to real ones by providing a connection between the relay protection terminal and the information model. The equipment used at the stand does not require significant capital investments, and therefore this approach is available to most design and training organizations. Keywords: digital protection terminal, experimental stand, analog-to-digital converter; digital-to-analog converter, mathematical model, induction motor.
- 30 June 2023
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- Vol. 37 (113) , 17-25
RESEARCH OF DIGITAL PROTECTION TERMINALS
Due to the development of technologies, the widely used electromechanical relays in the electric power industry have been replaced by multifunctional digital relay protection terminals. For the training of students and electrical personnel of enterprises, new approaches to the creation of experimental stands are needed, which will allow us to study the features of the use of digital protection and fully reveal their capabilities. The purpose of the work is to improve the quality of the knowledge and practical skills received by students in working with digital protection blocks. To achieve the goal, a specialized laboratory stand for testing digital security terminals has been developed. The stand consists of a mathematical model of the protected object and hardware, due to which the model mode parameters are converted into physical signals and fed in real time to a real digital device. The study of the protected element is provided in the characteristic modes of its operation close to real ones by providing a connection between the relay protection terminal and the information model. The equipment used at the stand does not require significant capital investments, and therefore this approach is available to most design and training organizations. Keywords: digital protection terminal, experimental stand, analog-to-digital converter; digital-to-analog converter, mathematical model, induction motor.