Latest Publications
- 1 January 2025
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- Vol. 43 (119) , 61-69
Analysis of the Features of Implementing Differential Protections of Extra High Voltage Power Transmission Lines
Nowadays, there is a need for constant analysis of the operation of relay protection and improvement of the principles of its implementation, due to the fact that microprocessor technologies are rapidly developing and being implemented in relay protection. The purpose of the research is to develop directions for improving protection and ensuring the correct operation of differential-phase protection of 750 kV lines based on microprocessor devices. Therefore, the objectives of this study are an in-depth analysis of the principle of operation of this protection and determining directions for solving the problem. The scientific value is to actualize the problem for improving the algorithm of operation of differential-phase high-frequency protection of extra-high voltage lines. The practical significance of the research lies in increasing the efficiency of relay protection of the country's power system. There is used the method of analysis of the available scientific and technical literature to identify the problem in this paper. There are considered both existing protections and the principles of their operation, as well as new theoretical and experimental models of protections that have not yet been implemented. The characteristics of protections and the features of the scope of application are analyzed. Difficulties were identified in implementing the differential phase protection algorithm in microprocessor terminals specifically for long extra-high voltage lines of 330-750 kV. Lines of this voltage have a large capacitive component, which leads to the appearance of complex transients. These processes affect both the value of the measured parameters and the quality of the signal transmitted over the high-frequency channel. All this affects the selectivity of operation and increases the time of protection operation, thereby reducing the stability of the power system. The result of the research is confirmation of the relevance of the problem and the determination that an effective way to solve this problem is to build a mathematical model of the research object for further in-depth consideration. There was established that the problem of implementing microprocessor protection of extra-high voltage lines is not solved based on the analysis of scientific and technical literature. New directions in solving this problem are proposed by improving the algorithm of protection to ensure the stability of the unified power system of Ukraine. There is established that an effective way to solve this problem is to build a mathematical model of a specific extra-high voltage line of Ukraine and study the operation of a new method of protecting such lines. Keywords: relay protection, differential protection, differential-phase protection, high-frequency protection, extra-high voltage line, transients, short circuits, modeling, power system.
- 1 January 2025
- Published by Odessa Polytechnic National University in ELECTRICAL AND COMPUTER SYSTEMS
- Vol. 43 (119) , 61-69
Analysis of the Features of Implementing Differential Protections of Extra High Voltage Power Transmission Lines
Nowadays, there is a need for constant analysis of the operation of relay protection and improvement of the principles of its implementation, due to the fact that microprocessor technologies are rapidly developing and being implemented in relay protection. The purpose of the research is to develop directions for improving protection and ensuring the correct operation of differential-phase protection of 750 kV lines based on microprocessor devices. Therefore, the objectives of this study are an in-depth analysis of the principle of operation of this protection and determining directions for solving the problem. The scientific value is to actualize the problem for improving the algorithm of operation of differential-phase high-frequency protection of extra-high voltage lines. The practical significance of the research lies in increasing the efficiency of relay protection of the country's power system. There is used the method of analysis of the available scientific and technical literature to identify the problem in this paper. There are considered both existing protections and the principles of their operation, as well as new theoretical and experimental models of protections that have not yet been implemented. The characteristics of protections and the features of the scope of application are analyzed. Difficulties were identified in implementing the differential phase protection algorithm in microprocessor terminals specifically for long extra-high voltage lines of 330-750 kV. Lines of this voltage have a large capacitive component, which leads to the appearance of complex transients. These processes affect both the value of the measured parameters and the quality of the signal transmitted over the high-frequency channel. All this affects the selectivity of operation and increases the time of protection operation, thereby reducing the stability of the power system. The result of the research is confirmation of the relevance of the problem and the determination that an effective way to solve this problem is to build a mathematical model of the research object for further in-depth consideration. There was established that the problem of implementing microprocessor protection of extra-high voltage lines is not solved based on the analysis of scientific and technical literature. New directions in solving this problem are proposed by improving the algorithm of protection to ensure the stability of the unified power system of Ukraine. There is established that an effective way to solve this problem is to build a mathematical model of a specific extra-high voltage line of Ukraine and study the operation of a new method of protecting such lines. Keywords: relay protection, differential protection, differential-phase protection, high-frequency protection, extra-high voltage line, transients, short circuits, modeling, power system.
- Open Access
- 29 January 2024
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 4(87),p. 197-208
ТЕСТУВАННЯ МІКРОПРОЦЕСОРНИХ ТЕРМІНАЛІВ РЕЛЕЙНОГО ЗАХИСТУ В РОЗРАХУНКОВИХ РЕЖИМАХ
Цифровізація у електроенергетиці є невід’ємною частиною цифрової економіки. Не менш важливим завданням при підготовці фахівців електротехнічних спеціальностей є цифровізація освітнього процесу. Для її вирішення потрібне впровадження програмних комплексів, із застосуванням яких майбутні фахівці зможуть моделювати об’єкти електроенергетичної системи, але на більш комфортній та безпечній платформі. Необхідно проведення дослідження функціональних можливостей мікропроцесорних терміналів релейного захисту та автоматизації шляхом їх комп’ютерного моделювання з урахуванням поведінки захистів у характерних для елемента, що захищається режимах роботи. У роботі розглянуто питання моделювання цифрового пристрою релейного захисту на прикладі струмої відсічки для асинхронного електродвигуна напругою 6 кВ при трифазному короткому замиканні з можливістю перегляду результатів моделювання. Синтезовані: імітаційна модель схеми струмової відсічки асинхронного двигуна; субсистема, що дозволяє моделювати коротке замикання асинхронного двигуна при регульованих уставках струму і часу. У ході проведення експерименту на моделі є можливість розрахувати параметри спрацьовування захистів мікропроцесорного терміналу і перевірити правильність роботи захистів, а також вивчення нормальних та аварійних режимів роботи об’єкта, що захищається. Оцінка результатів моделювання дозволяє забезпечити налаштування мікропроцесорного захисту. Спільне використання розробленої моделі та експериментального стенду дозволяють досягти найповнішого дослідження функціональних можливостей мікропроцесорних пристроїв релейного захисту. Порівняння результатів експериментів з моделями дозволяє стверджувати, що розбіжності між розрахунковими та експериментальними даними не перевищують 4–6 %, в статичних режимах, та 12–14 %, в динамічних режимах.
- 29 January 2024
- Published by Kherson National Technical University in Вісник Херсонського національного технічного університету
- No. 4(87),p. 197-208
Open AccessТЕСТУВАННЯ МІКРОПРОЦЕСОРНИХ ТЕРМІНАЛІВ РЕЛЕЙНОГО ЗАХИСТУ В РОЗРАХУНКОВИХ РЕЖИМАХ
Цифровізація у електроенергетиці є невід’ємною частиною цифрової економіки. Не менш важливим завданням при підготовці фахівців електротехнічних спеціальностей є цифровізація освітнього процесу. Для її вирішення потрібне впровадження програмних комплексів, із застосуванням яких майбутні фахівці зможуть моделювати об’єкти електроенергетичної системи, але на більш комфортній та безпечній платформі. Необхідно проведення дослідження функціональних можливостей мікропроцесорних терміналів релейного захисту та автоматизації шляхом їх комп’ютерного моделювання з урахуванням поведінки захистів у характерних для елемента, що захищається режимах роботи. У роботі розглянуто питання моделювання цифрового пристрою релейного захисту на прикладі струмої відсічки для асинхронного електродвигуна напругою 6 кВ при трифазному короткому замиканні з можливістю перегляду результатів моделювання. Синтезовані: імітаційна модель схеми струмової відсічки асинхронного двигуна; субсистема, що дозволяє моделювати коротке замикання асинхронного двигуна при регульованих уставках струму і часу. У ході проведення експерименту на моделі є можливість розрахувати параметри спрацьовування захистів мікропроцесорного терміналу і перевірити правильність роботи захистів, а також вивчення нормальних та аварійних режимів роботи об’єкта, що захищається. Оцінка результатів моделювання дозволяє забезпечити налаштування мікропроцесорного захисту. Спільне використання розробленої моделі та експериментального стенду дозволяють досягти найповнішого дослідження функціональних можливостей мікропроцесорних пристроїв релейного захисту. Порівняння результатів експериментів з моделями дозволяє стверджувати, що розбіжності між розрахунковими та експериментальними даними не перевищують 4–6 %, в статичних режимах, та 12–14 %, в динамічних режимах.