TTTomoko Tabata

Tomoko Tabata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomoko Tabata has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Yasushi Shimada

    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    6 shared publications
  • Takaaki Sato

    Department of Oral Biomedical Engineering, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo

    4 shared publications
  • Masaomi Ikeda

    Department of Oral Biomedical Engineering, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo

    3 shared publications
  • Yasunori Sumi

    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan

    3 shared publications
  • Yasushi Shimada

    Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan

    3 shared publications
  • Alireza Sadr

    Department of Restorative Dentistry, University of Washington, Seattle, WA 98195, USA

    2 shared publications

Latest Publications

  • Open Access

    Remineralization-Related Effects of Multi-Ion Cements on Demineralized Dentin

    by Zijuan Du, Tomoko Tabata, Masayuki Otsuki, Noriko Hiraishi, Chen Zeng, Yasunori Sumi, Yasushi Shimada

  • Open Access

    Shear Bond Strength of Orthodontic Brackets on Demineralized Enamel Before and After Application of a Resin Infiltrant Remineralizing Agent: An In Vitro Study

    by Ahmed Almahrul, Ikuo Yonemitsu, Tomoko Tabata, Masaomi Ikeda, Yuka Tanaka-Takemura, Yasushi Shimada, Takashi Ono

    Background/Objectives: We evaluated whether resin infiltration treatment of demineralized enamel improves shear bond strength (SBS). Methods: Thirty permanent bovine incisor teeth were assigned randomly into three groups (n = 10 per group): control group, demineralized enamel pretreated with ICON® resin infiltrant (Exp1 group), and demineralized enamel without pretreatment (Exp2). Demineralization was induced using a pH 4.5 solution for 21 days and was monitored using swept-source optical coherence tomography on days 0, 7, 14, and 21. The lesion depth (LD) was quantified and evaluated using ImageJ software. In the Exp1 group, ICON® was applied prior to bracket bonding; no pretreatment was applied in the Exp2 group. In all groups, brackets were bonded using Super-Bond/Clear fluoride-free self-cure adhesive resin (4-META/MMA-TBB, Sun Medical) following Phosphoric acid (65%; Red Activator, Sun Medical). After debonding, enamel surfaces were evaluated to determine the adhesive remnant index (ARI). Results: No significant difference (p = 0.631) was noted in LD between Exp1 and Exp2 groups. The SBS values significantly differed (p < 0.05) between the control (4.1 ± 1.0 MPa) and Exp1 (5.5 ± 1.4 MPa) groups and between the Exp1 and Exp2 (3.8 ± 1.3 MPa) groups. However, SBS did not differ significantly between the control and Exp2 groups. Furthermore, ARI scores showed no significant difference between the control and Exp1 groups, whereas the Exp2 group recorded significantly elevated ARI scores relative to the control group (p = 0.0127). Conclusions: These findings suggest that resin infiltration with ICON® may improve bracket adhesion on demineralized enamel.

  • Open Access

    Marginal adaptation analysis of CAD/CAM resin crown with non-invasive methods

    by Chen Zeng, Tomoko Tabata, Rena Takahashi, Masaomi Ikeda, Junichi Shinagawa, Hisaichi Nakagawa, Yumi Tsuchida, Shunsuke Takano, Yasunori Sumi, Yasushi Shimada

    Objectives: This study compared the silicone replica method with swept-source optical coherence tomography (SS-OCT) to analyze marginal adaptation and investigated the effect of the light incidence angle of SS-OCT on measurement precision. Materials and methods: A typodont-prepared mandibular right first molar was scanned using an intraoral scanner (Trios 3). Fourteen crowns were fabricated from CAD/CAM resin blocks (Katana Avencia P) using a 5-axis milling machine (DWX-50). Marginal adaptation at the buccal, lingual, mesial, and distal points was assessed using the silicone replica method and SS-OCT at light incidence angles of 60°, 75°, and 90°. Statistical comparisons were performed using two-way analysis of variance (ANOVA) and t-tests with Bonferroni correction, and t-tests at a significance level of 0.05. Results: At 60°, SS-OCT showed significantly larger marginal discrepancies than the silicone replica method at the buccal, lingual, and mesial points (p < 0.05). At 75°, only the lingual point showed a significantly larger value than the silicone replica method (p < 0.05). At 90°, no significant differences were observed between the SS-OCT and silicone replica methods (p > 0.05). Marginal discrepancy values increased as the angle changed from 90° to 75° to 60°, with significant differences between 60° and 75° and between 60° and 90° at the buccal and lingual points (p < 0.05). Conclusions: SS-OCT is a viable alternative to the silicone replica method for assessing marginal adaptation at an incidence angle of 90 °. Clinical relevance: SS-OCT, a non-invasive method, has the potential to be applied clinically for evaluating marginal fit in indirect restorations in vivo.


  • Open Access

    Comparing gap between dentin and composite using optical coherence tomography and leakage test

    by Abu Hasan Mohammad Khaled, Takaaki Sato, Tomoko Tabata, Mengtian Zhao, Kota Kibe, Masaomi Ikeda, Yasushi Shimada

    Purpose: The study aimed to compare the gap formation between dentin and resin composite using optical coherence tomography (OCT) and the leakage test.Methods: Three cavities were prepared for each bovine tooth (coronal, cervical, and root). Cavities were filled by Scotchbond Universal Plus Adhesive and Filtek Supreme Flowable Restorative. After 24 h storage in water, the interface was analyzed at the bottom of the cavity using OCT. They were then cut and immersed in 50% ammoniacal silver nitrate (AgNO3) solution and photo-development solution for a leakage test. Next, energy-dispersive X-ray spectroscopy (EDS) assessed the cavity bottom interface. Two-dimensional (2D) images of both devices were analyzed to calculate the sealed interface percentage (SI%). The mean SI% values for adhesive were statistically analyzed by multiple comparisons using the Kruskal-Wallis test followed by Dunn's test with Bonferroni correction, with the significance level set at α = 0.05.Results: No significant differences were observed among the three sites for either OCT (P < 0.05) or EDS (P < 0.05). Significant differences were observed between OCT and EDS at each site (P = 0.005, P < 0.001, P = 0.004, respectively). When comparing OCT and EDS, EDS detected significantly more white lines (lower SI%) in all locations.Conclusion: The OCT device showed different detection results compared to the conventional EDS-based leakage method. On the other hand, there was no significant difference in the measurements across different sites of the tooth with either method.

  • Open Access

    Bonding Performance of a New Resin Core System with a Low-Polymerization-Shrinkage Monomer to Root Canal Dentin

    by Takashi Hatayama, Tomoko Tabata, Kota Kibe, Masaomi Ikeda, Yasunori Sumi, Yasushi Shimada

    Resin core build-ups following root canal treatment still have many issues. This study evaluated whether a new low-polymerization-shrinkage resin core system (LC2) could address these issues by assessing its bonding performance to root canal dentin using microtensile bond strength tests and gap formation using swept-source optical coherence tomography (SS-OCT). Twenty-four extracted human lower premolars were used for bonding performance tests, while forty-eight sound extracted human wisdom teeth were used for gap observation. Four systems were compared: Luminous Core LC flow (LC1), LC2, MI Core LC flow (MIC), and Filtek Fill & Core (FFC). Cylindrical cavities were prepared, bonded, and filled with resin cores, and gap formation was evaluated. The results showed significant differences in bond strength between the coronal and apical sides: LC1 (coronal: 29.9 ± 3.8 MPa; apical: 12.4 ± 2.0 MPa), LC2 (coronal: 31.2 ± 3.6 MPa; apical: 17.8 ± 3.6 MPa), MIC (coronal: 28.7 ± 3.8 MPa; apical: 8.8 ± 2.1 MPa), and FFC (coronal: 29.0 ± 4.2 MPa; apical: 9.5 ± 1.9 MPa). LC2 exhibited significantly higher bond strength at the apical side compared to the other systems (p < 0.05). Gap formation was significantly reduced in LC2 (10.9 ± 5.0%) and FFC (11.9 ± 5.0%) compared to LC1 (31.8 ± 10.5%) and MIC (32.0 ± 5.6%) (p < 0.05). These findings suggest that LC2 is advantageous for resin core build-ups, particularly in improving adhesion to root canal dentin and reducing gap formation.


  • Degree of conversion and interfacial adaptation of touch-cure resin cement polymerized by self-curing or dual-curing with reduced light

    by Su Young Lee, Yasushi Shimada, Alireza Sadr, Tomoko Tabata, Takaaki Sato, Ji-Eun Byun, Seung-Hoon Han

    Objectives The first aim of this study was to determine whether there is a difference in degree of conversion (DC) of touch-cure cements polymerized by self-curing with adhesive or dual-curing under reduced light. The second aim was to compare interfacial adaptation of zirconia restoration cemented using touch-cure cements self-cured or dual-cured by reduced light. Methods The DC of touch-cure resin cements with adhesive was measured continuously using Fourier transform infrared spectrometry. Experimental groups differed depending on touch-cure cement. Each group had three subgroups of polymerization method. For subgroup 1, the DC was measured by self-curing. For subgroups 2 and 3, the DCs were measured by dual-curing with reduced light penetrating 3 mm and 1 mm zirconia blocks, respectively. For interfacial adaptation evaluation, Class I cavity was prepared on an extracted third molar, and zirconia restoration was fabricated. The restoration was cemented using the same cement. Groups and subgroups for interfacial adaptation were the same as those of the DC measurement. After thermo-cycling, interfacial adaptation at the tooth-restoration interface was evaluated using swept-source optical coherence tomography imaging. Results The DC of touch-cure cement differed depending on the measurement time, resin cement, and polymerization method (p < 0.05). Interfacial adaptation was different depending on the resin cement and polymerization method (p < 0.05). Conclusion For touch-cure cement, light-curing with higher irradiance presented a higher DC and superior interfacial adaptation than light-curing with lower irradiance or self-curing. Clinical relevance Although some adhesives accelerate the self-curing of touch-cure cement, light-curing for touch-cure cement is necessary for zirconia cementation.


  • Analysis of cariogenic biofilms by using a swept-source optical coherence tomography in vitro

    by Tomoko Tabata, Hisaichi Nakagawa, Khairul Matin, Masayuki Otsuki, Akira Aoki, Yasunori Sumi, Yasushi Shimada


  • Open Access

    Diagnosis of occlusal caries using optical coherence tomography in a real clinical situation

    by Tomoko Tabata, Hisaichi Nakagawa, Kota Kobayashi, Azusa Takeuchi, Ryohei Fujimori, Keitaro Dohi, Riko Nakamura, Hirotoshi Iwabuchi, Tadamu Gondo, Yukiko Tsuji, et al.

    Purpose: Optical coherence tomography (OCT) is an imaging device that can create cross-sectional images of tooth structure. This study evaluated the diagnostic performance of dental OCT system for occlusal caries in a real clinical situation.Methods: Twenty-four occlusal locations on 20 teeth were selected from 12 patients (mean age: 39.6 years). Swept-source OCT (SS-OCT) images were taken from the occlusal surfaces to diagnose occlusal enamel caries using the international caries detection and assessment system (ICDAS) grading. Indices of sensitivity and specificity for the detection of superficial enamel demineralization (code 1), distinct enamel demineralization (code 2), and enamel caries (code 3) were calculated from the results of visual inspection and SS-OCT obtained by three dentists with less than 2 years clinical experience.Results: The sensitivity of visual inspection and SS-OCT for enamel demineralization (code 1) were 0.22 and 0.55; for enamel demineralization (code 2) were 0.50 and 0.61; and for enamel caries (code 3) were 0.22 and 0.44, respectively. The specificity of visual inspection and SS-OCT were 0.52 and 0.78, respectively.Conclusion: SS-OCT can provide excellent diagnostic performance for occlusal enamel caries in a real clinical situation.


  • Open Access

    Evaluation of Incipient Enamel Caries at Smooth Tooth Surfaces Using SS-OCT

    by Yasushi Shimada, Takaaki Sato, Go Inoue, Hisaichi Nakagawa, Tomoko Tabata, Yuan Zhou, Noriko Hiraishi, Tadamu Gondo, Syunsuke Takano, Kei Ushijima, et al.

    (1) Background: Dental caries, if diagnosed at the initial stage, can be arrested and remineralized by a non-operative therapeutic approach preserving tooth structure. Accurate and reproducible diagnostic procedure is required for the successful management of incipient caries. The aim of this study was to evaluate the diagnostic accuracy of 3D swept-source optical coherence tomography (3D SS-OCT) for enamel caries at smooth tooth surface if the lesion was with remineralization. (2) Methods: Forty-seven tooth surfaces of 24 extracted human teeth visibly with/without enamel caries (ICDAS code 0–3) were selected and used in this study. The tooth surfaces of investigation site were cleaned and visually examined by four dentists. After the visual inspection, SS-OCT scanning was performed onto the enamel surfaces to construct a 3D image. The 2D tomographic images of the investigation site were chosen from the 3D dataset and dynamically displayed in video and evaluated by the examiners. A five-rank scale was used to score the level of enamel caries according to the following; 1: Intact enamel. 2: Noncavitated lesion with remineralization. 3: Superficial noncavitated lesion without remineralization. 4: Deep nonvacitated lesion without remineralization. 5: Enamel lesion with cavitation. Sensitivity and specificity for 3D OCT image and visual inspection were calculated. Diagnostic accuracy of each diagnostic method was calculated using weighted kappa. Statistical significance was defined at p = 0.05. (3) Results: 3D SS-OCT could clearly depict enamel caries at smooth tooth surface as a bright zone, based on the increased backscattering signal. It was noted that 3D SS-OCT showed higher sensitivity for the diagnosis of remineralized lesions and deep enamel lesions without cavitation, as well as cavitated enamel lesions (p < 0.05). No significant difference of specificity was observed between the two diagnostic methods (p > 0.05). Furthermore, 3D SS-OCT showed higher diagnostic accuracy than visual inspection (p < 0.05). (4) Conclusions: Within the limitations of this in vitro study, 3D SS-OCT showed higher diagnostic capacity for smooth surface enamel caries than visual inspection and could also discriminate lesion remineralization of enamel caries.