Takaaki Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takaaki Sato has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Junji Tagami
Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 254 Phaya Thai Rd, Wang Mai, Pathum Wan, Bangkok, 10330, Thailand; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
7 shared publications- Yasushi Shimada
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
6 shared publications Tomohiro Takagaki
Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Asahi University
5 shared publicationsToru Nikaido
Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Asahi University
5 shared publicationsMasaomi Ikeda
Department of Oral Biomedical Engineering, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo
4 shared publications- Tomoko Tabata
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan
4 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (1) , 40-43
Effect of ion implantation on adhesion to zirconia material
Purpose: This study was designed to investigate the effect of silicon (Si) ion implantation on the strength of zirconia bonding to resin cement.Methods: Si ions were implanted in a sintered zirconia plate at an acceleration energy of 50 or 100 keV. The implantation dose was divided into four subgroups of 1 × 1013, 1 × 1014, 1 × 1015, or 1 × 1016 ions/cm2. A total of nine groups were set up, including a control group. Stainless steel rods were bonded to the zirconia plates using resin cement and subjected to tensile bond strength testing. Other plates were subjected to surface roughness measurement and elemental analyses.Results: In the tensile bond strength test, some groups exhibited significantly higher values than the control group. The surface roughness measured using a confocal laser scanning microscope showed no significant differences in any group compared with the control group. The elemental analyses showed that X-ray photoelectron spectroscopy was able to detect Si ions that could not be detected by energy-dispersive X-ray spectroscopy.Conclusion: Despite the limitations of this study, it proved possible to implant Si ions into zirconia materials. It was also suggested that the strength of zirconia bonding to resin cement could be improved by irradiation.
- 1 January 2026
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 68 (1) , 40-43
Open AccessEffect of ion implantation on adhesion to zirconia material
Purpose: This study was designed to investigate the effect of silicon (Si) ion implantation on the strength of zirconia bonding to resin cement.Methods: Si ions were implanted in a sintered zirconia plate at an acceleration energy of 50 or 100 keV. The implantation dose was divided into four subgroups of 1 × 1013, 1 × 1014, 1 × 1015, or 1 × 1016 ions/cm2. A total of nine groups were set up, including a control group. Stainless steel rods were bonded to the zirconia plates using resin cement and subjected to tensile bond strength testing. Other plates were subjected to surface roughness measurement and elemental analyses.Results: In the tensile bond strength test, some groups exhibited significantly higher values than the control group. The surface roughness measured using a confocal laser scanning microscope showed no significant differences in any group compared with the control group. The elemental analyses showed that X-ray photoelectron spectroscopy was able to detect Si ions that could not be detected by energy-dispersive X-ray spectroscopy.Conclusion: Despite the limitations of this study, it proved possible to implant Si ions into zirconia materials. It was also suggested that the strength of zirconia bonding to resin cement could be improved by irradiation.
- Open Access
- 25 January 2025
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 44 (1) , 52-59
The influence of phosphoric acid and primer treatment on the evaluation of the adhesive resin cement/enamel interface
This study evaluated the influence of phosphoric acid and primer on enamel bonding performance using Panavia V5. Ground bovine enamels were assigned: using K-etchant syringe and Tooth Primer (CT), using K-etchant syringe (PA), using Tooth Primer (TP), neither K-etchant syringe nor Tooth Primer was used (NC). The micro-tensile bond strength values of CT and PA were significantly higher than TP. After thermal cycling, the values were higher in CT and PA. In the leakage test, line-shaped signal pattern at the adhesive interface was detected in NC, and the signal was partially detected in PA and TP. Observation of the adhesive interface after acid and base challenge confirmed tooth-like structures in groups except NC. Large spaces were observed between the enamel and cement in NC. Limited in this study, the lack of application of phosphoric acid or Tooth Primer may affect the enamel bonding performance.
- 25 January 2025
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 44 (1) , 52-59
Open AccessThe influence of phosphoric acid and primer treatment on the evaluation of the adhesive resin cement/enamel interface
This study evaluated the influence of phosphoric acid and primer on enamel bonding performance using Panavia V5. Ground bovine enamels were assigned: using K-etchant syringe and Tooth Primer (CT), using K-etchant syringe (PA), using Tooth Primer (TP), neither K-etchant syringe nor Tooth Primer was used (NC). The micro-tensile bond strength values of CT and PA were significantly higher than TP. After thermal cycling, the values were higher in CT and PA. In the leakage test, line-shaped signal pattern at the adhesive interface was detected in NC, and the signal was partially detected in PA and TP. Observation of the adhesive interface after acid and base challenge confirmed tooth-like structures in groups except NC. Large spaces were observed between the enamel and cement in NC. Limited in this study, the lack of application of phosphoric acid or Tooth Primer may affect the enamel bonding performance.
- Open Access
- 1 January 2025
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 25 (1) , 5-9
Comparing gap between dentin and composite using optical coherence tomography and leakage test
Purpose: The study aimed to compare the gap formation between dentin and resin composite using optical coherence tomography (OCT) and the leakage test.Methods: Three cavities were prepared for each bovine tooth (coronal, cervical, and root). Cavities were filled by Scotchbond Universal Plus Adhesive and Filtek Supreme Flowable Restorative. After 24 h storage in water, the interface was analyzed at the bottom of the cavity using OCT. They were then cut and immersed in 50% ammoniacal silver nitrate (AgNO3) solution and photo-development solution for a leakage test. Next, energy-dispersive X-ray spectroscopy (EDS) assessed the cavity bottom interface. Two-dimensional (2D) images of both devices were analyzed to calculate the sealed interface percentage (SI%). The mean SI% values for adhesive were statistically analyzed by multiple comparisons using the Kruskal-Wallis test followed by Dunn's test with Bonferroni correction, with the significance level set at α = 0.05.Results: No significant differences were observed among the three sites for either OCT (P < 0.05) or EDS (P < 0.05). Significant differences were observed between OCT and EDS at each site (P = 0.005, P < 0.001, P = 0.004, respectively). When comparing OCT and EDS, EDS detected significantly more white lines (lower SI%) in all locations.Conclusion: The OCT device showed different detection results compared to the conventional EDS-based leakage method. On the other hand, there was no significant difference in the measurements across different sites of the tooth with either method.
- 1 January 2025
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 25 (1) , 5-9
Open AccessComparing gap between dentin and composite using optical coherence tomography and leakage test
Purpose: The study aimed to compare the gap formation between dentin and resin composite using optical coherence tomography (OCT) and the leakage test.Methods: Three cavities were prepared for each bovine tooth (coronal, cervical, and root). Cavities were filled by Scotchbond Universal Plus Adhesive and Filtek Supreme Flowable Restorative. After 24 h storage in water, the interface was analyzed at the bottom of the cavity using OCT. They were then cut and immersed in 50% ammoniacal silver nitrate (AgNO3) solution and photo-development solution for a leakage test. Next, energy-dispersive X-ray spectroscopy (EDS) assessed the cavity bottom interface. Two-dimensional (2D) images of both devices were analyzed to calculate the sealed interface percentage (SI%). The mean SI% values for adhesive were statistically analyzed by multiple comparisons using the Kruskal-Wallis test followed by Dunn's test with Bonferroni correction, with the significance level set at α = 0.05.Results: No significant differences were observed among the three sites for either OCT (P < 0.05) or EDS (P < 0.05). Significant differences were observed between OCT and EDS at each site (P = 0.005, P < 0.001, P = 0.004, respectively). When comparing OCT and EDS, EDS detected significantly more white lines (lower SI%) in all locations.Conclusion: The OCT device showed different detection results compared to the conventional EDS-based leakage method. On the other hand, there was no significant difference in the measurements across different sites of the tooth with either method.
- 2 August 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (8) , 1-13
Degree of conversion and interfacial adaptation of touch-cure resin cement polymerized by self-curing or dual-curing with reduced light
Objectives The first aim of this study was to determine whether there is a difference in degree of conversion (DC) of touch-cure cements polymerized by self-curing with adhesive or dual-curing under reduced light. The second aim was to compare interfacial adaptation of zirconia restoration cemented using touch-cure cements self-cured or dual-cured by reduced light. Methods The DC of touch-cure resin cements with adhesive was measured continuously using Fourier transform infrared spectrometry. Experimental groups differed depending on touch-cure cement. Each group had three subgroups of polymerization method. For subgroup 1, the DC was measured by self-curing. For subgroups 2 and 3, the DCs were measured by dual-curing with reduced light penetrating 3 mm and 1 mm zirconia blocks, respectively. For interfacial adaptation evaluation, Class I cavity was prepared on an extracted third molar, and zirconia restoration was fabricated. The restoration was cemented using the same cement. Groups and subgroups for interfacial adaptation were the same as those of the DC measurement. After thermo-cycling, interfacial adaptation at the tooth-restoration interface was evaluated using swept-source optical coherence tomography imaging. Results The DC of touch-cure cement differed depending on the measurement time, resin cement, and polymerization method (p < 0.05). Interfacial adaptation was different depending on the resin cement and polymerization method (p < 0.05). Conclusion For touch-cure cement, light-curing with higher irradiance presented a higher DC and superior interfacial adaptation than light-curing with lower irradiance or self-curing. Clinical relevance Although some adhesives accelerate the self-curing of touch-cure cement, light-curing for touch-cure cement is necessary for zirconia cementation.
- 2 August 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (8) , 1-13
Degree of conversion and interfacial adaptation of touch-cure resin cement polymerized by self-curing or dual-curing with reduced light
Objectives The first aim of this study was to determine whether there is a difference in degree of conversion (DC) of touch-cure cements polymerized by self-curing with adhesive or dual-curing under reduced light. The second aim was to compare interfacial adaptation of zirconia restoration cemented using touch-cure cements self-cured or dual-cured by reduced light. Methods The DC of touch-cure resin cements with adhesive was measured continuously using Fourier transform infrared spectrometry. Experimental groups differed depending on touch-cure cement. Each group had three subgroups of polymerization method. For subgroup 1, the DC was measured by self-curing. For subgroups 2 and 3, the DCs were measured by dual-curing with reduced light penetrating 3 mm and 1 mm zirconia blocks, respectively. For interfacial adaptation evaluation, Class I cavity was prepared on an extracted third molar, and zirconia restoration was fabricated. The restoration was cemented using the same cement. Groups and subgroups for interfacial adaptation were the same as those of the DC measurement. After thermo-cycling, interfacial adaptation at the tooth-restoration interface was evaluated using swept-source optical coherence tomography imaging. Results The DC of touch-cure cement differed depending on the measurement time, resin cement, and polymerization method (p < 0.05). Interfacial adaptation was different depending on the resin cement and polymerization method (p < 0.05). Conclusion For touch-cure cement, light-curing with higher irradiance presented a higher DC and superior interfacial adaptation than light-curing with lower irradiance or self-curing. Clinical relevance Although some adhesives accelerate the self-curing of touch-cure cement, light-curing for touch-cure cement is necessary for zirconia cementation.
- Open Access
- 25 May 2023
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 42 (3) , 311-318
Influence of different tooth etchants on bur-cut and uncut enamel
This study aimed to evaluate the effect of pre-etching for two-step self-etch adhesive bonding to bur-cut and uncut enamel. Bur-cut and uncut enamel surfaces were assigned to surface treatments of no etchant (CT), Enamel Conditioner (EC; Shofu, Kyoto, Japan), or K-etchant syringe (KE; Kuraray Noritake Dental, Tokyo, Japan). The bonded samples were thermal cycled and evaluated by microshear bond strength (μSBS). The adhesive interface after acid-base challenge and the conditioned enamel surfaces were morphologically analyzed using scanning electron microscopy (SEM). For bur-cut enamel, EC and KE pre-etching significantly improved μSBS. For uncut enamel, KE showed higher μSBS than EC. SEM observation revealed that only KE removed the prismless layer of the uncut enamel surface. EC could improve enamel bonding and appears to be a substitute for phosphoric acid, especially for bur-cut enamel. However, uncut enamel could not be effectively conditioned by EC with a lower bond strength than KE.
- 25 May 2023
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 42 (3) , 311-318
Open AccessInfluence of different tooth etchants on bur-cut and uncut enamel
This study aimed to evaluate the effect of pre-etching for two-step self-etch adhesive bonding to bur-cut and uncut enamel. Bur-cut and uncut enamel surfaces were assigned to surface treatments of no etchant (CT), Enamel Conditioner (EC; Shofu, Kyoto, Japan), or K-etchant syringe (KE; Kuraray Noritake Dental, Tokyo, Japan). The bonded samples were thermal cycled and evaluated by microshear bond strength (μSBS). The adhesive interface after acid-base challenge and the conditioned enamel surfaces were morphologically analyzed using scanning electron microscopy (SEM). For bur-cut enamel, EC and KE pre-etching significantly improved μSBS. For uncut enamel, KE showed higher μSBS than EC. SEM observation revealed that only KE removed the prismless layer of the uncut enamel surface. EC could improve enamel bonding and appears to be a substitute for phosphoric acid, especially for bur-cut enamel. However, uncut enamel could not be effectively conditioned by EC with a lower bond strength than KE.
- Open Access
- 1 January 2023
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 23 (2) , 20-23
Diagnosis of occlusal caries using optical coherence tomography in a real clinical situation
Purpose: Optical coherence tomography (OCT) is an imaging device that can create cross-sectional images of tooth structure. This study evaluated the diagnostic performance of dental OCT system for occlusal caries in a real clinical situation.Methods: Twenty-four occlusal locations on 20 teeth were selected from 12 patients (mean age: 39.6 years). Swept-source OCT (SS-OCT) images were taken from the occlusal surfaces to diagnose occlusal enamel caries using the international caries detection and assessment system (ICDAS) grading. Indices of sensitivity and specificity for the detection of superficial enamel demineralization (code 1), distinct enamel demineralization (code 2), and enamel caries (code 3) were calculated from the results of visual inspection and SS-OCT obtained by three dentists with less than 2 years clinical experience.Results: The sensitivity of visual inspection and SS-OCT for enamel demineralization (code 1) were 0.22 and 0.55; for enamel demineralization (code 2) were 0.50 and 0.61; and for enamel caries (code 3) were 0.22 and 0.44, respectively. The specificity of visual inspection and SS-OCT were 0.52 and 0.78, respectively.Conclusion: SS-OCT can provide excellent diagnostic performance for occlusal enamel caries in a real clinical situation.
- 1 January 2023
- Published by Asian Pacific Journal of Dentistry in Asian Pacific Journal of Dentistry
- Vol. 23 (2) , 20-23
Open AccessDiagnosis of occlusal caries using optical coherence tomography in a real clinical situation
Purpose: Optical coherence tomography (OCT) is an imaging device that can create cross-sectional images of tooth structure. This study evaluated the diagnostic performance of dental OCT system for occlusal caries in a real clinical situation.Methods: Twenty-four occlusal locations on 20 teeth were selected from 12 patients (mean age: 39.6 years). Swept-source OCT (SS-OCT) images were taken from the occlusal surfaces to diagnose occlusal enamel caries using the international caries detection and assessment system (ICDAS) grading. Indices of sensitivity and specificity for the detection of superficial enamel demineralization (code 1), distinct enamel demineralization (code 2), and enamel caries (code 3) were calculated from the results of visual inspection and SS-OCT obtained by three dentists with less than 2 years clinical experience.Results: The sensitivity of visual inspection and SS-OCT for enamel demineralization (code 1) were 0.22 and 0.55; for enamel demineralization (code 2) were 0.50 and 0.61; and for enamel caries (code 3) were 0.22 and 0.44, respectively. The specificity of visual inspection and SS-OCT were 0.52 and 0.78, respectively.Conclusion: SS-OCT can provide excellent diagnostic performance for occlusal enamel caries in a real clinical situation.
- Open Access
- 1 January 2023
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 65 (1) , 53-56
Analysis of reaction products on hydroxyapatite created by tooth etchants with different compositions
Purpose: The purpose of this study was to investigate the reaction products formed by application of three tooth etchants to hydroxyapatite.Methods: Tooth etchants with three different compositions, designed for application to teeth before dental adhesive – “ K-etchant GEL” (containing phosphoric acid), “Enamel Conditioner” (containing organic acids), and “Multi Etchant” (containing acidic monomer) – were applied to hydroxyapatite plates.Results: Atomic force microscopy measurements revealed that Multi Etchant formed nano-sized particles on the hydroxyapatite. X-ray diffraction and Fourier transform infrared spectrometer analyses of the powdered hydroxyapatite indicated that Enamel Conditioner produced calcium tartrate whereas K-etchant GEL generated monetite. These results indicated that each etchant reacted with hydroxyapatite in a different way.Conclusion: Not only differences among the etching ability of etchants, but also differences in the reaction compounds they produce may influence bonding performance in clinical practice.
- 1 January 2023
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 65 (1) , 53-56
Open AccessAnalysis of reaction products on hydroxyapatite created by tooth etchants with different compositions
Purpose: The purpose of this study was to investigate the reaction products formed by application of three tooth etchants to hydroxyapatite.Methods: Tooth etchants with three different compositions, designed for application to teeth before dental adhesive – “ K-etchant GEL” (containing phosphoric acid), “Enamel Conditioner” (containing organic acids), and “Multi Etchant” (containing acidic monomer) – were applied to hydroxyapatite plates.Results: Atomic force microscopy measurements revealed that Multi Etchant formed nano-sized particles on the hydroxyapatite. X-ray diffraction and Fourier transform infrared spectrometer analyses of the powdered hydroxyapatite indicated that Enamel Conditioner produced calcium tartrate whereas K-etchant GEL generated monetite. These results indicated that each etchant reacted with hydroxyapatite in a different way.Conclusion: Not only differences among the etching ability of etchants, but also differences in the reaction compounds they produce may influence bonding performance in clinical practice.
- Open Access
Evaluation of Incipient Enamel Caries at Smooth Tooth Surfaces Using SS-OCT
(1) Background: Dental caries, if diagnosed at the initial stage, can be arrested and remineralized by a non-operative therapeutic approach preserving tooth structure. Accurate and reproducible diagnostic procedure is required for the successful management of incipient caries. The aim of this study was to evaluate the diagnostic accuracy of 3D swept-source optical coherence tomography (3D SS-OCT) for enamel caries at smooth tooth surface if the lesion was with remineralization. (2) Methods: Forty-seven tooth surfaces of 24 extracted human teeth visibly with/without enamel caries (ICDAS code 0–3) were selected and used in this study. The tooth surfaces of investigation site were cleaned and visually examined by four dentists. After the visual inspection, SS-OCT scanning was performed onto the enamel surfaces to construct a 3D image. The 2D tomographic images of the investigation site were chosen from the 3D dataset and dynamically displayed in video and evaluated by the examiners. A five-rank scale was used to score the level of enamel caries according to the following; 1: Intact enamel. 2: Noncavitated lesion with remineralization. 3: Superficial noncavitated lesion without remineralization. 4: Deep nonvacitated lesion without remineralization. 5: Enamel lesion with cavitation. Sensitivity and specificity for 3D OCT image and visual inspection were calculated. Diagnostic accuracy of each diagnostic method was calculated using weighted kappa. Statistical significance was defined at p = 0.05. (3) Results: 3D SS-OCT could clearly depict enamel caries at smooth tooth surface as a bright zone, based on the increased backscattering signal. It was noted that 3D SS-OCT showed higher sensitivity for the diagnosis of remineralized lesions and deep enamel lesions without cavitation, as well as cavitated enamel lesions (p < 0.05). No significant difference of specificity was observed between the two diagnostic methods (p > 0.05). Furthermore, 3D SS-OCT showed higher diagnostic accuracy than visual inspection (p < 0.05). (4) Conclusions: Within the limitations of this in vitro study, 3D SS-OCT showed higher diagnostic capacity for smooth surface enamel caries than visual inspection and could also discriminate lesion remineralization of enamel caries.
Open AccessEvaluation of Incipient Enamel Caries at Smooth Tooth Surfaces Using SS-OCT
(1) Background: Dental caries, if diagnosed at the initial stage, can be arrested and remineralized by a non-operative therapeutic approach preserving tooth structure. Accurate and reproducible diagnostic procedure is required for the successful management of incipient caries. The aim of this study was to evaluate the diagnostic accuracy of 3D swept-source optical coherence tomography (3D SS-OCT) for enamel caries at smooth tooth surface if the lesion was with remineralization. (2) Methods: Forty-seven tooth surfaces of 24 extracted human teeth visibly with/without enamel caries (ICDAS code 0–3) were selected and used in this study. The tooth surfaces of investigation site were cleaned and visually examined by four dentists. After the visual inspection, SS-OCT scanning was performed onto the enamel surfaces to construct a 3D image. The 2D tomographic images of the investigation site were chosen from the 3D dataset and dynamically displayed in video and evaluated by the examiners. A five-rank scale was used to score the level of enamel caries according to the following; 1: Intact enamel. 2: Noncavitated lesion with remineralization. 3: Superficial noncavitated lesion without remineralization. 4: Deep nonvacitated lesion without remineralization. 5: Enamel lesion with cavitation. Sensitivity and specificity for 3D OCT image and visual inspection were calculated. Diagnostic accuracy of each diagnostic method was calculated using weighted kappa. Statistical significance was defined at p = 0.05. (3) Results: 3D SS-OCT could clearly depict enamel caries at smooth tooth surface as a bright zone, based on the increased backscattering signal. It was noted that 3D SS-OCT showed higher sensitivity for the diagnosis of remineralized lesions and deep enamel lesions without cavitation, as well as cavitated enamel lesions (p < 0.05). No significant difference of specificity was observed between the two diagnostic methods (p > 0.05). Furthermore, 3D SS-OCT showed higher diagnostic accuracy than visual inspection (p < 0.05). (4) Conclusions: Within the limitations of this in vitro study, 3D SS-OCT showed higher diagnostic capacity for smooth surface enamel caries than visual inspection and could also discriminate lesion remineralization of enamel caries.
- 25 July 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (4) , 903-910
Effect of repair systems on dentin bonding performance
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 25 July 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (4) , 903-910
Effect of repair systems on dentin bonding performance
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies