BTBaikozho R. Tashtanov

Baikozho R. Tashtanov

*This is an algorithmically generated author record based on publicly available information.

Baikozho R. Tashtanov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Early diagnosis of aseptic loosening of hip prosthetic components using acoustic arthrometry

    by Baikozho R. Tashtanov, Vitaliy V. Pavlov, Mikhail A. Rajfeld, Vasily N. Vasyukov, Andrey A. Korytkin, Васюков Василий Николаевич

    Background. One of the main causes of revision hip arthroplasty is aseptic loosening of prosthetic components. A non-invasive method for early detection of this complication is the assessment of prosthesis condition using a triaxial accelerometer — acoustic arthrometry. The aim of the study — to evaluate the potential of acoustic arthrometry for early diagnosis of aseptic loosening of prosthetic components and polyethylene liner wear in hip prostheses. Methods. The study was performed using a custom-designed device for non-invasive registration of vibrational and acoustic oscillations in the area of the implanted joint. Interpretation and analysis of the obtained acoustic signatures were performed using MATLAB software. Acoustic emission recordings were obtained from 120 patients: 40 with diagnosed aseptic loosening of prosthetic components, 40 with polyethylene liner wear, and 40 control patients with no complaints regarding prosthesis function. Predictors of aseptic loosening and polyethylene wear were identified using regression analysis. Results. In a multivariate risk model of polyethylene liner wear, ROC analysis demonstrated optimal sensitivity (91.7%) and specificity (84.6%) of the proposed method. For diagnosing aseptic loosening of prosthetic components, the sensitivity and specificity were 79.5% and 65.8%, respectively. Conclusion. Specific acoustic signatures analyzed using the developed evaluation criteria (Peak, Asymmetry, Width) correlated with radiographic findings and showed high specificity (84.6%) and sensitivity (91.7%). These results support the feasibility of using acoustic arthrometry as a screening tool for early detection of prosthetic component loosening and polyethylene wear.


  • Open Access

    Audiogram of ceramic friction noises in total hip arthroplasty and their relationship with acetabular component position

    by B. R. Tashtanov, V. V. Pavlov, М. А. Райфельд, V. N. Vasyukov, N. B. Baktyyarov, A. A. Korytkin

    Introduction Noise from a total hip replacement's ceramic friction pair is known as hip squeaking. Acoustic arthrometry in total hip replacement (THR) involves using acoustic emission technology to visualize sound characteristics. The objective was to identify the possibility of identifying noises of a THR ceramic friction pair using the acoustic arthrometry and to determine the relationship of noises with the position of the acetabular component. Material and methods The retrospective study included 36 patients who underwent THR with a ceramic bearing pair. Seven patients (19.44 %) reported noise at the site of the THR joint. The patients were divided into two groups based on the noise ( n = 7) and no noise reported ( n = 29). Clinical and radiological parameters were reviewed through online survey considering age, follow-up period, BMI, inclination and anteversion of the acetabular component. Acoustic arthrometry was performed for 10 patients with the pulse height, PEAK, ASYMMETRY and WIDTH measured and compared. Results Comparative analysis of individual clinical and radiological parameters showed no statistically significant differences in the two groups. However, deviations by any of the two criteria in the acetabular component position was 20.7 % in the no-noise group and 57.1 % in the noise reported group ( p = 0.048). Acoustic emission of THR with noise had visual differences in acoustic signature with the mean PEAK measuring 0.492 in the no-noise group and 0.488 in the noise reported group; ASYMMETRY being 0.012 versus 0.015 and WIDTH measuring 479.2 versus 486.5, respectively. Discussion The findings correlated with the results of previous studies and confirmed the relationship between the angles of the implanted acetabular component and the noise. In contrast to previous studies of acoustic arthrometry, the method offered facilitated objective statistical noise assessment in addition to visualization and analysis of acoustic signatures. Conclusion The study demonstrated possibilities of acoustic arthrometry in identification of different states of the ceramic friction pair, characterization of the noise detected and its quantification.

  • Open Access

    Safe zone for the acetabular component in the concept of spinopelvic relationships

    by A. V. Peleganchuk, E. N. Turgunov, E. A. Mushkachev, B. R. Tashtanov, V. V. Pavlov, A. A. Korytkin

    «Зона безопасности» ацетабулярного компонента в концепции позвоночно-тазовых взаимоотношений

  • Open Access

    Feasibility of Vibration Arthrometry in Hip Arthroplasty: A Review

    by Baikozho R. Tashtanov, Mikhail A. Rajfeld, Vasily N. Vasyukov, Vitaliy V. Pavlov, Andrey A. Korytkin, Васюков Василий Николаевич

    Background. In recent years, the attention of researchers to the diagnostic method based on acoustic or vibration emission (arthrometry) has increased. The method makes it possible to detect destructive changes in the bearing components of endoprosthesis, thereby predicting their early loosening and taking appropriate preventive measures. The aim of the review is to analyse the degree of development of vibration arthrometry methods and its role in identifying early (pre-radiological) signs of loosening of endoprosthesis components and destructive changes in them (adverse events) after hip arthroplasty. Methods. The information was searched in eLIBRARY, PubMed, Google Scholar, and Crossref electronic databases in Russian and English. The search was performed using the following keywords: acoustic emission, vibration arthrography, vibration arthrometry, hip joint, arthroplasty. The depth of the search: from 1990 to March 2024. Results. A total of 34 literature sources were selected. None of the studied technologies was included in the number of generally accepted medical studies, since all have significant limitations, such as dependence on the density of soft tissues surrounding the endoprosthesis, the unresolved issue of the sensors location. Also, most of the technologies have not been tested in vivo, which would show their real potential for subsequent integration into the medical system. Nevertheless, most experimental studies have demonstrated a positive result in the diagnosis of loosening, destruction of the cement mantle and endoprosthesis components. Conclusions. The advantage of vibration arthrometry as an independent diagnostic method is that it confirms loosening of endoprosthesis components, destruction of the cement mantle and ceramics at early stages before radiographic manifestations of ongoing processes.


  • Processing and analysis of signals for diagnosing the condition of a hip joint endoprosthesis

    by Vasily N. Vasyukov, Mikhail A. Rajfeld, Darya O. Sokolova, Baikozho R. Tashtanov, Vitaly V. Pavlov

    One of the problems associated with hip arthroplasty is that the endoprosthesis is subjected to significant mechanical loads, which can lead to its destruction. Revision surgeries aimed at determining the condition of the prosthesis are complex and expensive, in addition, they are asso-ciated with the need for the patient to arrive at a medical facility and be hospitalized. An approach to diagnosing a hip endoprosthesis during the patient's normal life is proposed, based on the analysis of vibration and sound oscillations taken from the body surface using a device developed for this purpose based on a three-axis accelerometer. The device for recording vibration and sound oscillations has small dimensions and weight, is fixed on the ilium and practically does not limit the patient's movements during signal recording. The signals are recorded in digital form on a memory card, which, after measurements are taken, can be removed from the device and used to transfer the recording to a computer for processing and analysis. Analysis of the records of signals obtained experimentally allowed to identify signs of various defects (partial abrasion of the polyethylene liner, complete abrasion of the liner and loosening of the prosthesis stem in the area of its attachment to the femur). Statistics are proposed for making a decision when testing hypotheses about the presence/absence of these defects. The results of the experiments are presented.


  • Open Access

    The potential utility of phage therapy in the treatment of periprosthetic infection caused by multidrug-resistant pathogens: a review

    by Taalaibek Sheraliev, Alexander Samokhin, Baikozho Tashtanov, Andrey Korytkin, Vitaliy Pavlov

    Background. One of the main and most costly problems in large joint arthroplasty associated with socially significant losses is periprosthetic infection. Of particular importance is periprosthetic joint infection (PJI) caused by antibiotic-resistant pathogens and followed by the worst treatment results. Currently, when antibiotic-resistant pathogens are spreading rapidly, particularly in health facilities, researchers are constantly looking for alternative treatments for severe cases of PJI. Phage therapy can be one of these methods. The aim of the review was to analyse the application of personalized bacteriophages in the management of periprosthetic infection caused by multidrug-resistant pathogens during arthroplasty of large joints of the lower extremities. Methods. A 20-year literature search (2003-2023) was performed in the eLIBRARY, PubMed, Google Scholar, and Scopus electronic databases. Results. During the search, 1.482 publications meeting the objectives of this review were found. Taking into account the inclusion/non-inclusion criteria adopted by the authors, the review included 12 studies describing 45 cases of the use of bacteriophages in the management of hip and knee PJI caused by multidrug-resistant pathogens. The infection was eradicated without recurrence in 42 cases (89.4%), recurrence was recorded only in 5 cases (10.6%). Conclusions. The analysis of the literature confirms that a combination therapy of personalized phages and antibiotics as adjuvant therapy is safe and effective. Bacteriophage treatment is a promising direction in the fight against resistant pathogens of periprosthetic infection. Its combination with antibiotics seems to be the most promising, as it can significantly increase the effectiveness of therapy for infections caused by multidrug-resistant pathogens due to the synergy of these drug classes.


  • Open Access

    Ceramic-related noise as an adverse outcome in total hip arthroplasty

    by B. R. Tashtanov, I. A. Kirilova, D. V. Pavlova, V. V. Pavlov

    Introduction Ceramic hip replacement bearings have shown to be low wearing and biocompatible. The last two generations of Biolox Forte and Biolox Delta ceramics have have established themselves as durable bearings. However, squeaking and noise from ceramic bearing THRs is well recognised in the 21st century.The objective was to explore the problem of noise in the ceramic bearing of THA based on the analysis of the foreign and Russian literature.Material and methods In presented the analysis of Foreign and Russian literature searches for the review were produced according to PRISMA recommendations using PubMed, Scopus, Google Scholar, eLibrary. MINOR was used to assess the methodological quality of articles.Results and Discussion Noise in ceramics is observed in 37.7 %. There are many theories on the origin and mechanism of noise including liner impingement and loading, film disruption, third body, microseparation and resonance. However, there is still no consensus on what is noise in the ceramic bearing and how to solve this problem.Conclusion Literature review of ceramic bearing indicated enough unanswered questions. The noise may play a role as a predictor of improper use of endoprosthesis with accumulated database resulting in better understanding of the phenomenon, methods of the correction and timely prevention of ceramic breakage.


  • Open Access

    Ceramic Liner Fracture in Total Hip Arthroplasty: A Case Report

    by Baikozho R. Tashtanov, Andrey A. Korytkin, Vitaliy V. Pavlov, Igor I. Shubnyakov

    Background. Ceramic component fracture is a severe complication of primary and revision total hip arthroplasty, leading to multiple revision surgeries. Case report. This report of rare clinical case of ceramic liner fracture. Fifteen months after a planned left hip replacement, the patient experienced anterior surface pain in the area of the operated joint accompanied by creaking, so the patient went for a consultation. Based on the results of the consultation, the patient was urgently hospitalized and underwent a delayed surgery for revision arthroplasty. Radiologically, there was varus position of the femoral component, dislocation of the bearings. MSCT showed ceramic liner fracture and fragment dislocation. Intraoperatively, the multifragmentary fracture of the liner, significant damage to the head, and retroversion of the acetabular component (retroversion was detected on the preoperative CT scan) were identified. All components of the endoprosthesis and tribologic bearings were replaced with identical ones, total synovectomy was performed, and the wound was cleaned and sanitized. Conclusion. The presented case report demonstrates the danger of incorrect positioning of the components when using a ceramic bearings. In this case, retroversion of the acetabular component and varus position of the femoral component resulted in a reduced contact area between the head and the liner, which caused the ceramic to fracture. The described observation confirms the need for further in-depth study of the ceramic bearings in order to prevent ceramic component fracture, as it leads to severe complications and significant economic costs.