AKAndrey Aleksandrovich Korytkin

Andrey Aleksandrovich Korytkin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrey Aleksandrovich Korytkin has a total of 173 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spectral features of ultraviolet laser-induced fluorescence in human glioblastoma tissues

    by N. A. Maslov, P. M. Larionov, I. A. Rozhin, V. V. Stupak, M. S. Selyakova, T. M. Terekhova, I. A. Kirilova, A. A. Korytkin, Н. А. Маслов, П. М. Ларионов, et al.

    Today, various fluorescent methods are widely used for intraoperative diagnosis of malignant brain tumors. However, all of them rely on exogenous fluorophores. Meanwhile, UV-induced autofluorescence may also be of interest. The aim of the study was to identify characteristic spectra of glioblastoma tissues using ultraviolet laser-induced fluorescence spectroscopy. Material and methods.  Morphological and laser fluorescence studies were conducted on resected glioblastoma tissues from three patients. Microscopy and morphometry with hematoxylin and eosin staining were employed. Using a tunable wavelength laser (210–290 nm), excitation-emission matrices of laser-induced fluorescence were measured. Results and discussion.  Principal component analysis (narrow peak method) enabled the identification of three component spectra contributing to the fluorescence of the samples. These components correspond to different forms of tryptophan, with intensity maxima at wavelengths of 315 nm and 330 nm, and connective tissue. The primary malignant brain tumors studied were significantly heterogeneous; however, the ratio of the intensities of the fluorescent components differs for samples with varying tissue elements content – tumor parenchyma, necrotic parenchyma, and stromal elements. Conclusions.  Spectral changes associated with tryptophan fluorescence, quantitatively determined by the ratio of the intensities of the above-described components, can be used as a new biomarker for glioma and may serve as the basis for developing an optical, minimally invasive method for determining tumor boundaries.

  • Open Access

    Adjuvant phage therapy in periprosthetic joint infection: comparative analysis of medium-term treatment results

    by V. V. Pavlov, T. U. Sheraliev, A. G. Samokhin, S. O. Chretien, N. V. Tikunova, Yu. N. Kozlova, V. L. Lukinov, I. A. Kirilova, A. A. Korytkin, В. В. Павлов, et al.

    Introduction Periprosthetic joint infection (PJI) is one of the major complications following primary and revision total hip arthroplasty, accounting for 15–25 % of revision procedures. PJI caused by multidrug-resistant microorganisms is associated with a higher risk of recurrence and severe consequences, including loss of limb function and amputation. The growing prevalence of antimicrobial resistance, particularly among staphylococci and Gram-negative bacteria, further complicates the PJI treatment. Purpose To conduct a comparative analysis of the mid-term results of adjuvant phage therapy in combination with standard therapy in patients with periprosthetic hip joint infection caused by multidrug-resistant microorganisms. Materials and Methods The study was designed as a non-randomized, open-label, prospective study that included 39 patients with chronic periprosthetic hip joint infection (hip PJI). All patients underwent appropriate surgical treatment and were divided into two groups: the study group ( n = 19), in which personalized phage therapy was used in combination with targeted antibiotic therapy, and the comparison group ( n = 20), which received antibiotic therapy alone. The median follow-up period was at least 120 weeks; the recurrence rate was assessed after 104 weeks. The primary criterion for treatment efficacy was eradication of PJI and the absence of PJI recurrence within 104 weeks after revision arthroplasty. Results The odds of PJI recurrence within 104 weeks of follow-up in the study group were five times lower than in the comparison group ( OR = 0.2), with recurrence rates of 10.5 % and 45.0 %, respectively ( p = 0.031). The study group demonstrated significantly higher implant survival compared with the comparison group: implant survival at 104 weeks reached 89 % and 55 %, respectively. The mean risk ratio for implant loss in the David Cox proportional hazards model was 0.17 (log-rank test, p = 0.012). The study group also showed a significantly higher proportion of recovered patients compared with the comparison group, with rates of 89.5 % and 55.0 %, respectively ( OR = 6.3; p = 0.031). Discussion The results obtained for the causative PJI agents are consistent with the data in the literature. Both groups were dominated by cefoxime-resistant forms of staphylococci as a marker antibiotic, which reflects the PJI patterns of development in arthroplasty. The use of antibacterial drugs in large doses for eradication of pathogenic bacteria in biofilms leads to the accumulation of mutations in the genomes of the causative PJI agents, which is the reason for the development of drug resistance and recurrence of infection. The use of alternative therapies for PJI, in particular phage therapy, may change the treatment strategy. Adjuvant phage therapy has potential in the PJI caused by antibiotic-resistant pathogens. Conclusion Adjuvant phage therapy combined with antibiotic therapy is an effective treatment modality for periprosthetic hip joint infection caused by multidrug-resistant pathogens and may significantly reduce the recurrence rate of periprosthetic infection and thereby improve clinical outcomes. Further large randomized studies are required to confirm our findings and to use this method.

  • Open Access

    Structural proteins and transcription regulators in cultured articular cartilage cells of the femoral head in congenital hip dislocation

    by N. Yu. Pakhomova, E. L. Strokova, A. I. Shevchenko, V. V. Kozhevnikov, S. V. Zalavina, D. V. Zhukov, D. A. Pakhomova, A. M. Zaydman, A. A. Korytkin, Пахомова Н. Ю, et al.

    The aim of the study was to investigate immunocytochemical and morphometric parameters of cells obtained from the articular cartilage of the femoral head in congenital hip dislocation. Material and methods . Cell cultures were obtained and three passages of cultivation were performed using cells from the intermediate (middle) zone of the articular cartilage of the weight-bearing surface of the femoral head in 15 patients (8 girls and 7 boys) with congenital hip dislocation (hip dysplasia) who were undergoing treatment at the Research Department of Pediatric Vertebrology and Orthopedics at the Ya. L. Tsivyan Research Institute of Traumatology and Orthopedics. The mean age of the patients was 3 years 5 months ± 1 year 4 months. The fixed cells were examined by immunocytochemistry for a nuclear-cytoplasmic marker (Musashi1), nuclear markers (SOX9, SOX10, SOX2, PAX3, PAX6) and cytoplasmic markers (βIII-Tubulin, Collagen II, HNK1, Nestin), and analyzed by confocal scanning microscopy. The morphometric parameters of immunocytochemically stained cells were studied, the nuclear-cytoplasmic index was calculated, and the cytoplasmic structures of the cells were assessed using the ImageJ software. Statistical analysis was performed using Microsoft Office Excel and the Statistica 10.0 software package. Results . During cultivation of articular cartilage cells from the femoral head in congenital hip dislocation (hip dysplasia), two distinct cell types were identified. The first cell type showed positive immunocytochemical staining for the main chondrogenic antibodies to Collagen II and SOX9, and the cells were characterized as chondroblasts and chondrocytes. The second cell type showed positive results upon immunocytochemical detection of neural markers (PAX6, Nestin, βIII-Tubulin), including markers characteristic of neural crest cells (Musashi1, PAX3, SOX2, SOX10, HNK1), and was identified as cells of neurogenic differentiation. A comparative analysis of the morphometric parameters of chondrogenic and neuron-like cells revealed statistically significant differences. Conclusion . The results of the present study demonstrate the presence of cells with a neurogenic phenotype during cultivation of the articular cartilage of the femoral head in congenital hip dislocation (hip dysplasia). The neurogenic-type cells, presumably originating from neural crest cells, are not determined toward the molecular and biochemical processes involved in cartilage formation, which may lead to the development of a degenerative-dysplastic process during the embryonic period and to the manifestation of the pathology (congenital hip dislocation) after birth.

  • Open Access

    First clinical experience with a custom-made acetabular implant featuring a zinc-containing biocoating for the treatment of deep periprosthetic surgical site infections

    by Irina А. Kirilova, Кирилова Ирина Анатольевна, Peter M. Larionov, Ларионов Петр Михайлович, Maxim V. Efimenko, Ефименко Максим Владимирович, Evgeniya A. Anastasieva, Анастасиева Евгения Андреевна, Vyacheslav A. Bazlov, Базлов Вячеслав Александрович, et al.

    INTRODUCTION: Periprosthetic joint infection (PJI) of the hip is one of the leading causes of revision hip arthroplasty. An analysis of current treatment practices has shown increasing PJI recurrence rates, along with a rise in Gram-negative infections in the PJI etiology. Our study examined the clinical course of acute infection caused by Staphylococcus aureus / Klebsiella pneumoniae in a patient treated with a prototype acetabular component with a zinc-containing calcium phosphate coating applied by microarc oxidation, used as a spacer. CASE DESCRIPTION: We present a clinical case of a patient with chronic deep periprosthetic infection (recurrence) after total hip arthroplasty of the right hip. A custom implant with a zinc-containing calcium phosphate coating was used. Surgical treatment included removal of the right hip prosthesis, debridement of the surgical site, implantation of the custom implant, and placement of an Osteomed femoral component as a spacer. On postoperative day 21, a fistula appeared and was considered a PJI recurrence. On day 22, a repeat procedure was performed: total removal of the articulating spacer (custom acetabular component with Zn-containing coating), intraoperative sampling of tissue surrounding the acetabular and femoral components, and placement of a block spacer. In material from the implant screw holes and surrounding tissues, we found areas of subtotal necrosis of loose connective tissue interspersed with dense, diffuse inflammatory infiltrate of polynuclear leukocytes. Elemental analysis showed no zinc ions in the tissues surrounding the implant. CONCLUSION: The implant with zinc-containing calcium phosphate coating did not exhibit bactericidal activity in acute PJI, as there was no diffusion of zinc ions into the surrounding tissues, or diffusion was too weak to provide sufficient zinc locally.

  • Morphometric Features of Growth Plate Cells in the Proximal Tibia in Blount's Disease

    by E. L. Strokova, N. Y. Pakhomova, A. I. Shevchenko, V. V. Kozhevnikov, D. V. Zhukov, S. V. Zalavina, A. A. Yakovleva, M. O. Naursbayeva, A. M. Zaidman, A. A. Korytkin

    The aim of the study was to study the morphometric parameters of growth plate cells in the proximal tibia in Blount's disease. Material and methods. The study was conducted on cells isolated from the medial growth plates of the proximal tibia in Blount's disease grade III–IV. The material was obtained from 12 children (4 boys and 8 girls) (n=12) aged 3–9 years at the clinic of pediatric orthopedics of the Ya.L. Tsivyan Novosibirsk Research Institute of Traumatology and Orthopedics. The cells were cultured from passages 1 to 4, fixed, and stained for key chondrogenic (collagen type II and SOX 9 ) and neural (SOX 2 , SOX 10 , PAX 3 , PAX 6 , MSI 1 , Nestin, HNK 1 , TUBB 3 , NF 200 ) markers. Morphometric analysis of immunopositive cells was performed using ImageJ software. The obtained data were processed using standard statistical methods with the application of the Shapiro–Wilk test and Student's t-test. Results. Fluorescence staining of most growth plate cells revealed a positive reaction for the studied chondrogenic markers. Among these immunopositive cells, bipolar and multipolar cells with two or more processes expressing early (SOX 2 , SOX 10 , PAX 3 , PAX 6 , MSI 1 , Nestin, HNK 1 ) and late (TUBB 3 , NF 200 ) neural markers were identified. During cultivation, an increase in the proportion of positively stained cells for the majority of the studied neural markers was observed, along with an increase in fluorescence intensity, an increase in the number of processes, and an increase in the mean process length. Statistically significant differences in morphometric parameters (nuclear area, cytoplasmic area, and cell area) combined with differences in the nuclear-to-cytoplasmic ratio were found between cells expressing chondrogenic and neuronal markers. Conclusion. The results indicate the presence of cells of neural origin in the growth plate of the proximal tibia in Blount's disease. Positive staining for the transcription factors PAX 3 , PAX 6 , SOX 2 , SOX 10 , as well as for the markers HNK 1 , MSI 1 , Nestin, and TUBB 3 , supports the hypothesis regarding the role of neural crest cells in the development of this pathology.

  • Open Access

    Impact of an AI-assisted automated system on the clinical workload of orthopedic trauma surgeons and the quality of medical documentation

    by Tariel Z. Mamuladze, Irina A. Kirilova, Andrey A. Korytkin, Andrey P. Sereda, Sergey V. Mishinov

    Background. The increasing volume of clinical information under conditions of limited time and human resources places a substantial burden on medical personnel and increases the risk of errors in routine tasks, including the completion of medical records. Automation of medical documentation using artificial intelligence (AI) technologies represents a promising approach to reducing time costs and improving the quality of clinical data management. The aim of the study — to evaluate the impact of an AI-assisted automated system on the clinical workload of an orthopedic trauma surgeon and the quality of medical documentation. Methods. A retrospective comparative before-after study was conducted. An automated system integrating automatic speech recognition (ASR), natural language processing (NLP), and generative text modules was implemented in the clinical workflow. Three orthopedic trauma surgeons with more than 10 years of professional experience participated in the study. Data from 480 electronic medical records of patients hospitalized for primary total hip arthroplasty were analyzed (240 before and 240 after system implementation). The following parameters were evaluated: time required for completing medical records, frequency of record returns for correction by the quality control department, subjective workload assessed using the adapted Russian version of the NASA-TLX, and physician satisfaction assessed using a 5-point Likert scale. Results. After system implementation, the average time required to complete a full medical record decreased from 92.4±14.7 to 48.1±11.2 minutes (p 0.001). The proportion of records returned for revision decreased from 18.3% to 6.7% (p = 0.004). The mean NASA-TLX score reflecting subjective workload decreased from 67.5±8.2 to 48.9±7.1 (p = 0.002). Physician satisfaction with the system averaged 4.3 out of 5.0 points on the Likert scale. Conclusion. Implementation of an automated system incorporating artificial intelligence technologies significantly reduces the time required for medical documentation, improves its quality, and decreases the cognitive workload of physicians. These findings support the potential of AI-based tools to optimize clinical workflows and improve efficiency in orthopedic practice.


  • Деконтаминация бактериальной целлюлозы с помощью ультрафиолетового лазерного излучения

    by Н.а. Маслов, П.м. Ларионов, И.а. Рожин, Т.м. Терехова, А.а. Корыткин

    Бактериальная целлюлоза (БЦ) – перспективный природный биоматериал, который рассматривается в качестве альтернативы синтетическим полимерам для медицинского и фармацевтического применения. Протоколы очистки БЦ нацелены на удаление микробов-продуцентов и остатков их метаболизма. В данной работе изучается возможность использования УФ-лазерного излучения для дополнительной очистки БЦ и применение лазерноиндуцированной флуоресцентной (ЛИФ) спектроскопии для мониторинга ее микробного загрязнения. Изучены протокол очистки БЦ с максимальным сроком обработки 0,1 М NaOH – 30 суток и последующая УФ-обработка. Спектры ЛИФ регистрировали в диапазоне длин волн возбуждения 220–290 нм. Для более точной интерпретации результатов те же образцы исследовали методом лазерной сканирующей микроскопии (LSM). Результаты показали, что образцы БЦ после обработки щелочью демонстрируют признаки флуоресценции триптофана и тирозина, что указывает на наличие микробных остатков. Более того анализ с использованием методов LSM позволил выявить ДНК содержащие включения «тельца» размерами 1–2 мкм после щелочной обработки. УФ-облучение БЦ в суммарной дозе 12 Дж/см2 значительно снижала плотность «телец», а также соответствующие сигналы тирозина и триптофана, однако, не устраняла их полностью.

  • Open Access

    Remote rehabilitation in patients with hip or knee replacement: a prospective multicenter randomized controlled comparative trial

    by Gennadii E. Sheiko, Nikolaj N. Karyakin, Anna N. Belova, Vadim D. Daminov, Irina G. Gorokhova, Vladimir A. Bronnikov, Elena L. Medvedeva, Sergey V. Muravyev, Ksenia A. Sklyannaya, Svetlana V. Romanova, et al.

    INTRODUCTION. Interruption of the recovery process and lack of exercise or activities at home after discharge from a medical facility lead to a loss of the results achieved at various stages of medical rehabilitation (MR). In this regard, remote rehabilitation care is becoming particularly important. Issues related to the effectiveness and safety of remote rehabilitation remain insufficiently studied. AIM. To assess the effectiveness and safety of remote physical rehabilitation (RPR) for patients who have undergone hip or knee replacement surgery and to study patients' adherence to remote medical rehabilitation. MATERIALS AND METHODS. The trial included 150 patients aged 30 to 75 years who underwent HR or KR. The trial participants were assigned to groups in a 1 : 1 ratio for RPR in addition to routine clinical practice of providing MR (RPR group) or conducting only routine MR (comparison group). The patients in the comparison group were instructed to perform physical exercises independently at home on a daily basis. Routine MR included lifestyle modification and non-steroidal anti-inflammatory drugs when pain syndrome developed. The effectiveness and safety of rehabilitation measures were assessed using the data from the clinical and anamnestic examination, the 10-point visual-analog scale (VAS) of pain, the Timed Up and Go (TUG) test and the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) for assessing osteoarthritis of the knee and/or hip joint. RESULTS. 75 subjects were randomized to the remote physical rehabilitation group (57.2 ± 11.3 years) and 75 — to the comparison group (57.4 ± 9.0 years). Participation in the trial was completed by 56 patients from the RPR group and 63 patients in the comparison group. Comparing the results of rehabilitation between the groups 1 month after the inclusion of participants in the trial, a more pronounced statistically significant improvement in the patient's functional profile was found in the Timed Up and Go (TUG) test (р 0.001) and WOMAC (p 0.0001) in the RPR group. The most significant predictors of premature discontinuation of RPR were older age (χ2 = 18.922; p 0.001), education level ≤ 12 years (χ2 = 18.568; p 0.001), being a pensioner (χ2 = 26.901; p 0.001) and living in a rural area (χ2 = 33.629; p 0.001). The analysis of adverse events showed that 25 patients in the RPR group and 23 in the comparison group had a periodic increase in pain syndrome in the operated limb. DISCUSSION. The RPR model that has been developed involves the provision of personalized exercise programmes in the form of video clips, as well as the ability to monitor the patient's condition online. The findings indicated that remote physical rehabilitation for patients who have undergone arthroplasty of the large joints of the lower extremities is both safe and effective in terms of restoring functional mobility, reducing the risk of falls and the severity of pain syndrome, and increasing adherence to physical exercise. The primary constraints on the practical implementation of RPR pertain to the availability of high-speed Internet and skills in using Internet portals. CONCLUSION. RPR of patients who have undergone HR or KR is safe and effective in improving the functional profile and reducing the severity of pain syndrome.


  • Open Access

    Potential use of a new fully porous multi-hole titanium acetabular component with cemented liner fixation

    by Igor I. Shubnyakov, Andrey A. Korytkin, Aymen Riahi, Alexey O. Denisov, Alisagib A. Dzhavadov, Rashid M. Tikhilov

    Background. 3D printing technology has found widespread use in the production of custom-made and mass-produced acetabular components. Since the end of 2022, a new fully porous acetabular component with multiple screw holes and cemented liner fixation has been available. Research questions. In which clinical scenarios were the fully porous acetabular components used, and with which friction units? Which additional elements were used to achieve reliable primary fixation? What are the short-term survival rates of these implants and the functional outcomes of patients? Methods. The new component was used in 106 patients between October 2023 and December 2024. There were 55 (51.9%) women and 51 (48.1%) men. The average age was 60.7 years. In 11 (10.4%) cases, implantation was performed in complex cases of primary hip arthroplasty; in 48 (45.3%) cases, during aseptic revisions; and in 47 (44.3%) cases, during the second stage of infection-related revision. In all cases, screws were used for fixation, the number of which ranged from 2 to 10, with an average of 5.5. In 38 (35.8%) cases, acetabular components were combined with augments and/or cup-cage systems. In 47 (44.3%) cases, dual mobility cement fixation systems were used as a friction unit; in the remaining cases, cemented polyethylene liners were used. Results. The mean follow-up period was 14.1 months (range, 9-23 months). There were 18 (17.0%) complications, 10 of which required repeat revisions. Complications included 6 (5.7%) cases of infection, 5 (4.7%) cases of recurrent dislocations, 3 patients developing sciatic neuropathy, 2 cases of femoral component loosening, and 2 cases of periprosthetic fractures. No aseptic loosening of the acetabular component was observed. Conclusions. The advantages of the new acetabular component include the possibility of extended screw fixation and the use of different bearing surfaces, including dual mobility. This ensures reliable primary fixation and reduces the risk of recurrent dislocations. The use of a fully porous titanium acetabular cup with a cemented liner in complex primary and revision hip arthroplasty has demonstrated good radiographic results and early survival with a minimum follow-up of 9 months.

  • Open Access

    Early diagnosis of aseptic loosening of hip prosthetic components using acoustic arthrometry

    by Baikozho R. Tashtanov, Vitaliy V. Pavlov, Mikhail A. Rajfeld, Vasily N. Vasyukov, Andrey A. Korytkin, Васюков Василий Николаевич

    Background. One of the main causes of revision hip arthroplasty is aseptic loosening of prosthetic components. A non-invasive method for early detection of this complication is the assessment of prosthesis condition using a triaxial accelerometer — acoustic arthrometry. The aim of the study — to evaluate the potential of acoustic arthrometry for early diagnosis of aseptic loosening of prosthetic components and polyethylene liner wear in hip prostheses. Methods. The study was performed using a custom-designed device for non-invasive registration of vibrational and acoustic oscillations in the area of the implanted joint. Interpretation and analysis of the obtained acoustic signatures were performed using MATLAB software. Acoustic emission recordings were obtained from 120 patients: 40 with diagnosed aseptic loosening of prosthetic components, 40 with polyethylene liner wear, and 40 control patients with no complaints regarding prosthesis function. Predictors of aseptic loosening and polyethylene wear were identified using regression analysis. Results. In a multivariate risk model of polyethylene liner wear, ROC analysis demonstrated optimal sensitivity (91.7%) and specificity (84.6%) of the proposed method. For diagnosing aseptic loosening of prosthetic components, the sensitivity and specificity were 79.5% and 65.8%, respectively. Conclusion. Specific acoustic signatures analyzed using the developed evaluation criteria (Peak, Asymmetry, Width) correlated with radiographic findings and showed high specificity (84.6%) and sensitivity (91.7%). These results support the feasibility of using acoustic arthrometry as a screening tool for early detection of prosthetic component loosening and polyethylene wear.