ZPZhe Pan

Zhe Pan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhe Pan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electromagnetic-Mechanical Analysis of Parallel-Wound No-Insulation HTS Coils: Current-Imbalance-Induced Mechanical Response

    by Zhe Pan, Changhao Hu, Yi Lin, Lei Wang, Yunfei Tan, Jianzhao Geng

    Parallel-wound no-insulation (PW-NI) high-temperature superconducting (HTS) coils fabricated from stacked tapes significantly reduce charging delay while maintaining thermal stability. However, the PW-NI architecture leads to current imbalance, while the resulting mechanical response and the mechanism of screening-current-induced hoop stress specific to this configuration remain unclear. This study investigates the electromechanical behavior driven by current imbalance during charging and fast discharge, as well as the hoop strain induced by screening currents under a high background field. A multi-physics simulation model was developed by integrating the T-A formulation, an equivalent circuit network, and a discrete mechanical model. A three-tape PW-NI prototype coil was fabricated, and the electromagnetic component of the proposed model was validated through experiments conducted under various current ramping rates. The mechanical component was validated against experimental hoop strain measurements reported in the literature. Results indicate that non-uniform currents among parallel-wound tapes lead to hoop stress overshoots during charging. Under a high background field, the PW-NI coil induces localized screening current loops that concentrate near the edges of the stacked tapes, generating repulsive forces that widen the inter-turn gaps. During fast discharge, a large amount of coupling current is generated, shifting the repulsive forces to the intra-turn region and driving the expansion of intra-turn gaps. Furthermore, the effects of terminal resistance and contact resistivity on current imbalance and the resulting hoop stress were investigated. A semi-analytical expression was derived to rapidly estimate the maximum current difference between parallel-wound tapes, serving as an efficient surrogate model for parametric optimization. These results provide theoretical guidance for the design and application of PW-NI coils in large-scale magnets.


  • A Unified Model of DC Traction Power Supply System and Stray Current Dissipation

    by Wei Liu, Feilong Liu, Zhe Pan, Zhuoxin Yang, Jianbang Niu

    The problem of dc interference caused by stray currents in dc traction power supply system (DPS) is becoming increasingly serious. In order to study the interference degree of stray currents, a unified model of DPS and stray current dissipation based on the direct boundary element method (UBEM) has been established. The stray current collection network (SCCN) polarization potential is an important index to evaluate the leakage level of stray current. In this article, the relationship between SCCN polarization potential and rail-to-earth resistance (RE), train headways and longitudinal resistance of SCCN is investigated. It provides a partial theoretical basis and calculation method for stray current protection and system optimization. Field tests and CDEGS software simulations prove that UBEM is effective. The results show that UBEM is within 6.07% of the CDEGS simulation results and within 11.45% of the field test results. Taking the actual metro project in China as an example, SCCN polarization potential is only affected by local stray current. When RE>7.35 Ω·km, The average value of the SCCN polarization potential drops below 0.5 V.


  • Dynamic Simulation of Rail Potential and Stray Current Distribution Based on Fast Adaptive Boundary Element Algorithm

    by Linjie Zhou, Wei Liu, Zhe Pan, Yuning Tang, Songyuan Li, Jianbang Niu

    Currently, the impact of stray current is worsening. To control stray current and rail potential, over voltage protection device (OVPD), connection device (CD), and other equipment are widely used in metro. State transitions of the return system equipment cause dynamic changes in rail potentials, and together with changes in the surrounding heterogeneous soil structure, both directly affect the distribution of stray currents. Therefore, this paper proposes a method for calculating stray current and rail potential based on fast adaptive direct boundary element (FADBE), which takes into account the behavior process of reflux current equipment and surrounding geographical environment. FADBE not only greatly reduces iteration time, but also adaptively modifies parameters of reflux system. Through field experiments, the error in the calculation of FADBE is controlled within 6.87%. An authentic metro project is simulated and the results obtained from FADBE are found to be more consistent with the changes in rail potential and ground potential gradient observed. The results show that Different connections between the station and the main line can cause the surrounding ground potential gradient to vary by more than 43.47%. DC disturbances on metro lines near rivers and oceans should receive more attention.


  • A Field-Circuit Coupling Diffusion Model for Stray Current of DC Metro System

    by Wei Liu, Zhe Pan, Yuning Tang, Linjie Zhou, Ashfaque Ahmed Bhatti, Jianbang Niu

    Stray current in the DC metro system is commonly assessed using circuit or electric field models. Circuit models cannot accurately represent the stray current diffusion due to the track bed and soil resistivity effect on rail-to-earth resistance (RE). Meanwhile, electric field models lack detailed device modeling, which hampers their ability to comprehensive stray current analyses. To overcome these limitations, a field-circuit coupling diffusion model for stray current is proposed. The electric field submodel is established through the direct boundary element method (DBEM) for the metro reflux system (RS) and obtaining the mutual resistance matrix. The circuit submodel of the DC traction power system (DPS) is established based on the behavior characteristics of the RS devices. The dynamic stray current diffusion is obtained by coupling the two submodels through the mutual resistance matrix. The accuracy and efficiency in solving large systems with massive textures of the proposed model are verified by comparing them with the field test data and other existing methods. The case shows that strengthening the RE for a length of 500-meter on both sides of each traction power substation (TPS) can effectively reduce the earth potential gradient along the metro line.