Chenyang Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenyang Zhou has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Xiaolin Wang
Shanghai Jiao Tong University
3 shared publications - Fengming Ye
Shanghai Jiao Tong University
2 shared publications - Jiaxiang Wang
Shanghai Jiao Tong University
2 shared publications - Zhuoqing Yang
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Jianwei Hou
Shanghai Jiao Tong University
1 shared publication- Kangyi Lu
Department of Micro/Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University 1 , Shanghai 200240, China
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6805-6814
Data-Driven Geometric Optimization of Size-Adaptive 3-D Multimodal Microscaffolds for Conformal Organoid Interfacing
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6805-6814
Data-Driven Geometric Optimization of Size-Adaptive 3-D Multimodal Microscaffolds for Conformal Organoid Interfacing
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Self-Folding 3D Bioelectronic Micro-Cage with Dealloyed Nanoporous Electrodes for Multimodal Monitoring of Cardiac Organoids
The geometric mismatch between rigid planar microelectrode arrays (MEAs) and soft three-dimensional (3D) organoids, alongside high electrode-tissue interface impedance, limits the fidelity of in vitro bioelectronic interrogations. We present a self-folding 3D bioelectronic micro-cage featuring dealloyed nanoporous electrodes to omnidirectionally encapsulate hiPSC-derived cardiac organoids for multimodal electrophysiological and thermal monitoring. Fabricated via a wafer-scale MEMS process, the planar SiO2/PI bilayer utilizes an intrinsic residual stress gradient to spontaneously self-assemble into a 3D conformal cage upon release. Crucially, a magnetron co-sputtered Au-Cu alloy was employed for the electrode layer. During the selective etching of the Cu sacrificial layer, simultaneous dealloying occurs, generating a high-surface-area nanoporous gold electrode structure. The scaffold achieved a predictable folding radius optimized for ~500 μm organoids. The optimized nanoporous gold electrodes exhibited significantly reduced electrochemical impedance (8.3kΩ at 1 kHz) and a massively enhanced charge storage capacity (53 mC/cm²) compared to standard bare gold. Integrated serpentine resistive sensors exhibited highly linear temperature-dependent resistance changes (R² = 0.9993), enabling on-device temperature monitoring during organoid assays. Functionally, the micro-cage recorded synchronized 3D extracellular field potentials from cardiac organoids and monitored electrophysiological responses to externally applied thermal perturbations and pharmacological agents, including Verapamil and Norepinephrine. These results demonstrate a promising MEMS-compatible platform for organoid-based electrophysiological recording, temperature monitoring, and proof-of-concept drug-response assessment.
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Self-Folding 3D Bioelectronic Micro-Cage with Dealloyed Nanoporous Electrodes for Multimodal Monitoring of Cardiac Organoids
The geometric mismatch between rigid planar microelectrode arrays (MEAs) and soft three-dimensional (3D) organoids, alongside high electrode-tissue interface impedance, limits the fidelity of in vitro bioelectronic interrogations. We present a self-folding 3D bioelectronic micro-cage featuring dealloyed nanoporous electrodes to omnidirectionally encapsulate hiPSC-derived cardiac organoids for multimodal electrophysiological and thermal monitoring. Fabricated via a wafer-scale MEMS process, the planar SiO2/PI bilayer utilizes an intrinsic residual stress gradient to spontaneously self-assemble into a 3D conformal cage upon release. Crucially, a magnetron co-sputtered Au-Cu alloy was employed for the electrode layer. During the selective etching of the Cu sacrificial layer, simultaneous dealloying occurs, generating a high-surface-area nanoporous gold electrode structure. The scaffold achieved a predictable folding radius optimized for ~500 μm organoids. The optimized nanoporous gold electrodes exhibited significantly reduced electrochemical impedance (8.3kΩ at 1 kHz) and a massively enhanced charge storage capacity (53 mC/cm²) compared to standard bare gold. Integrated serpentine resistive sensors exhibited highly linear temperature-dependent resistance changes (R² = 0.9993), enabling on-device temperature monitoring during organoid assays. Functionally, the micro-cage recorded synchronized 3D extracellular field potentials from cardiac organoids and monitored electrophysiological responses to externally applied thermal perturbations and pharmacological agents, including Verapamil and Norepinephrine. These results demonstrate a promising MEMS-compatible platform for organoid-based electrophysiological recording, temperature monitoring, and proof-of-concept drug-response assessment.
- 1 September 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (5) , 051505
Organoid-on-a-chip: Current challenges, trends, and future scope toward medicine
In vitro organoid models, typically defined as 3D multicellular aggregates, have been extensively used as a promising tool in drug screening, disease progression research, and precision medicine. Combined with advanced microfluidics technique, organoid-on-a-chip can flexibly replicate in vivo organs within the biomimetic physiological microenvironment by accurately regulating different parameters, such as fluid conditions and concentration gradients of biochemical factors. Since engineered organ reconstruction has opened a new paradigm in biomedicine, innovative approaches are increasingly required in micro-nano fabrication, tissue construction, and development of pharmaceutical products. In this Perspective review, the advantages and characteristics of organoid-on-a-chip are first introduced. Challenges in current organoid culture, extracellular matrix building, and device manufacturing techniques are subsequently demonstrated, followed by potential alternative approaches, respectively. The future directions and emerging application scenarios of organoid-on-a-chip are finally prospected to further satisfy the clinical demands.
- 1 September 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (5) , 051505
Organoid-on-a-chip: Current challenges, trends, and future scope toward medicine
In vitro organoid models, typically defined as 3D multicellular aggregates, have been extensively used as a promising tool in drug screening, disease progression research, and precision medicine. Combined with advanced microfluidics technique, organoid-on-a-chip can flexibly replicate in vivo organs within the biomimetic physiological microenvironment by accurately regulating different parameters, such as fluid conditions and concentration gradients of biochemical factors. Since engineered organ reconstruction has opened a new paradigm in biomedicine, innovative approaches are increasingly required in micro-nano fabrication, tissue construction, and development of pharmaceutical products. In this Perspective review, the advantages and characteristics of organoid-on-a-chip are first introduced. Challenges in current organoid culture, extracellular matrix building, and device manufacturing techniques are subsequently demonstrated, followed by potential alternative approaches, respectively. The future directions and emerging application scenarios of organoid-on-a-chip are finally prospected to further satisfy the clinical demands.